• Title/Summary/Keyword: 전단율

Search Result 716, Processing Time 0.024 seconds

Development of Smart Speed Bump Using Non-newtonian Fluid (비뉴턴 유체를 이용한 스마트 과속방지턱 소재 개발)

  • Jung, Injun;Kim, Eunjung;Yu, Woong-Ryeol;Na, Wonjin
    • Composites Research
    • /
    • v.35 no.4
    • /
    • pp.277-282
    • /
    • 2022
  • In this study, a smart material applicable to speed bumps was developed using low-cost starch and waterbased suspensions, and their properties were investigated. Viscosity and shear stress according to the shear rate was measured by a rheometer to observe shear thickening behavior according to starch concentration. The shear thickening phenomenon and applicability to speed bumps were identified macroscopically via drop weight test and bike driving test, measuring the vibration after impact with a driving speed of 5-25 km/h. As a result of the viscosity measurement, shear thickening occurred after the shear thinning region at the beginning, and the critical strain causing the shear thickening phenomenon decreased as the concentration of starch increased. Also, the viscosity and shear stress increased significantly with the increase of the starch concentration. As a result of the drop weight test and the bike driving test, the suspension was changed to a solid-like state in a short time, and the impact energy was absorbed in the fluid. The shear thickening phenomenon easily occurred as the concentration of the fluid and the applied impact (velocity) increased. Therefore, it can be proposed the development of a smart speed bump material that operates in the range of 5-25 km/h with a Non-Newtonian fluid based on water and starch.

Experiment of Shear Behavior of Reinforced Concrete Beams with High Volume Fly Ash (하이 볼륨 플라이애쉬 철근콘크리트 보의 전단거동 실험)

  • Yoo, Sung-Won;Lee, Hyung-Jib
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.525-532
    • /
    • 2014
  • It is known that the best way to recycle fly ash is to use in concrete. It is impossible to bury in the ground this fly ash recently, so it is trying to use high volume fly ash concrete. Nevertheless, recent main research topics are focused in the part of material only, however, it is necessary to perform the research about structural shear behavior. Therefore, in this paper, 27 test members were manufactured with 3 test variables, namely fly ash replacement ratio 0, 35%, 50%, concrete compressive strength 20, 40, 60 MPa and 3 shear stirrups amounts. 27 test members were tested for shear behavior. From the test results, there were no differences between 35%, 50% high volume fly ash cement concrete and ordinary concrete without fly ash (FA=0%).

An Experimental Study on Longitudinal Shear Capacity of Composite Slab Embedded with Silence Insulator (방음재를 삽입한 합성슬래브의 수평전단성능에 관한 실험적 연구)

  • Lee, Seon-Keun;Lee, Chy-Hyoung;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.64-71
    • /
    • 2018
  • This paper provides the results for experimental study on longitudinal shear performance for new-concept composite slabs embedded with silence insulator. Longitudinal shear capacity tests are used to predict characteristics of composite action between the concrete block, silence insulator and deckplate. A total set of 7 Push-Down specimens are tested to clarify the composite action between the concrete block, silence insulator and deckplate. Parameters in this study are the width of T-type bar, the depth of reinforced bar and the thickness of silence insulator. The results from experimental study on longitudinal shear capacity for new-concept composite slabs applied T-type bar, Reinforced bar and Silence insulator are summarized as follows. In test result, the Longitudinal Shear Capacity of the new concept specimen is 2 times excellent than basic specimen with safety. It is expected that applying the proposed composite slab detail at the actual site will provide a significant safety factor in structural aspect of the existing composite slab, and greatly contribute to the improvement capacities of resisting vibration and sound.

Finite Element Analysis of Deformation Characteristics of the Shear Studs embedded in High Strength Concrete Slab of the Composite Beam (전단스터드의 변형특성에 관한 유한요소해석 -고강도 콘크리트를 사용한 합성보-)

  • Shin, Hyun Seop
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.5
    • /
    • pp.473-482
    • /
    • 2007
  • When the material strength and ductility of shear studs is sufficient to carry the interface shear force, the composite beam can behave safely without premature structural failure in the interface and without ultimate moment reduction. In this study, the influence of the deformation capacity of shear studs embedded in high-strength concrete on structural behavior and design condition of composite beam is analyzed using FEM. In the analysis, load type, degree of shear connection and arrangement of studs are considered as analysis parameters. According to analysis results, in the case of partial interaction,the deformation capacity of studs embedded in high-strength concrete should be considered together with material strength. Especially in the case of uniform arrangement of studs and uniformly distributed load, a minimum available degree of shear connection is restricted by the deformation capacity of studs. In this case,shear studs should be arranged in consideration of the distribution of shear force at the composite section.

A Study on the Side Shear Developed during Pullout of Suction Pile in Clays using 3D Numerical Analysis (3차원 수치해석을 이용한 점토지반에 설치된 석션파일 인발 시 발현되는 전단응력에 관한 연구)

  • Lee, Myungjae;Youn, Heejung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.59-66
    • /
    • 2014
  • This paper presents the pullout behavior of suction pile using finite difference method; and the commercial software, FLAC3D, was employed for the numerical analyses. The ultimate pullout capacity of suction pile was predicted using conventional equations, and the results were compared with the results from numerical analyses with varying pile diameter, pile length, and the undrained shear strength of clays. Based on the results from 24 analyses, it was found that the failure pattern depends not only on the drainage condition of suction pile, but also on the pile dimensions and the material properties of surrounding soils. The developed side shear (DSS) along the internal surface of the suction pile was collected from numerical analyses, which was used to classify the failure type between sliding failure and tensile failure. Regardless of the external DSS, the high internal DSS tends to result in sliding failure in the numerical analyses, which conforms well to the estimation from conventional equations.

Stress-strain Behavior of Remolded Clay Using Different Shear Rate and Plastic Indices (전단속도와 소성지수를 달리한 재생성 점성토의 응력-변형률 거동)

  • Lee, Yonghee;Kang, Kwon-Soo;Jung, Sang-Guk;Kang, Jintae;Kim, Daehyeon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • In general, the shear strength of a clay specimen under the direct shear test and the triaxial compression test increases with an increase in the shear rate. This study investigates the effects of shear rate and silt content on the stress-strain behavior of remolded Gwangyang clay, by changing the shear rate and the silt content. Based on the results of the triaxial compression tests, the equi-strain line of remolded Gwangyang clay shows initially positive slope and then becomes flat at certain strain level. As the strain level where the equistrain becomes flat is different depending on the soil with different silt contents, this can be considered as the inherent property of soil.

An experimental study on the measurement of real-scale tractive force using advanced shear plate (고성능 전단평판을 이용한 실규모 소류력 측정에 관한 연구)

  • Jung, Dong Gyu;Kim, Kwang Soo;Kim, Young Do;Park, Yong Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.14-14
    • /
    • 2021
  • 개수로에서는 반드시 자유수면이 있으며, 따라서 물과 공기와의 마찰은 관수로에 비해 상대적으로 매우 작고, 개수로의 전단응력 분포는 관수로와 달리 근본적으로 비대칭이다. 따라서 전단응력은 수로 바닥이나 측면에서만 작용하게 된다. 이러한 평균 전단응력 개념은 흐름에 의해 경계면 구성재료가 이동하는 이동상 수리학에서 유사이송 능력을 해석하는 기준이 되며, 경계면의 전단응력은 힘으로 표시하여 통상 소류력이라 한다. 이러한 복잡한 유체거동은 하천시설물 설계, 시공 및 관리에 있어서 구성재료의 보호능력에 따라 예상하지 못한 조건에서 쉽게 파손될 수 있다. 국내 하천의 경우 한계유속과 한계소류력에 의해 하천설계에 적용되고 있다. 한계 유속의 경우 간단한 수식에 의해 산정될 수 있지만 실제 하천의 보호능력을 대표하기는 힘들기 때문에 한계소류력이 동시에 고려되어야 한다. 한계소류력은 개수로 흐름에서 복잡하게 발생하는 이차류나, 난류 특성에 의해 산정하거나 예측하기는 매우 어렵다. 한계 소류력 뿐만 아니라 하천을 구성하는 재질의 조도계수 역시 균일하지 못하고 매우 예측하기 어렵다. 따라서 본 연구에서는 이러한 복잡한 양상을 나타내는 수리학적 요소에 대해 표준화된 실험수로에서 실험을 통해 평가하고, 체계화된 설계 지침이 되고자 연구를 진행하였다. 본 연구에서는 자연하천과 유사한 조건의 경사를 가지는 경사수로와 경사의 영향에서 자유롭게 평가를 진행하고자 기존 연구를 바탕으로 제작된 소류력 측정장치를 이용하였다. 하천의 설계나 평가에 적용되는 평균 소류력 개념은 복잡한 난류흐름에서 평가지표로써 대표하기 힘들기 때문에 유사 하천환경의 바닥에서 발생하는 소류력을 직접 측정하였다. 본 연구에 사용된 장치는 난류유속 u', v'을 이용하여 Reynolds stress산정하여 Total shear stress를 추정하는 기법을 사용하여 검증하였다.

  • PDF

Behavior of PSC Composite Bridge with Precast Decks (프리캐스트 바닥판 PSC 합성거더 교량의 거동)

  • Chung, Chul Hun;Hyun, Byung Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.873-880
    • /
    • 2006
  • PSC composite bridge with precast decks which was designed by the proposed horizontal shear equation was fabricated. Fatigue test was performed to evaluate the endurance of shear connection and the behavior of PSC composite bridge. After all the fatigue loading were applied, no crack and no residual slip were occurred. The flexural stiffness of PSC composite bridge was maintained the initial value, and demage of shear connection was not occurred. To verify the applicability of horizontal shear equation and shear connection detail and to evaluate the strength of PSC composite bridges, static test was also executed. PSC composite bridges with precast decks had 2.08 safety factor which was the ratio of crack to serviceability load and showed ductile behavior after ultimate load. Test results showed that the proposed design equation of the shear connection gave reasonable horizontal shear connection design. Fast and easy construction would be achieved using the suggested precast system.

Influence of Column Aspect Ratio on the Punching Shear Strength of Flat Plate Slab-Column Edge Connections (플랫 플레이트 슬래브-외부기둥 접합부의 뚫림전단강도에 대한 기둥 형상비의 영향)

  • Shin, Sung-Woo;Choi, Myung-Shin;Kim, Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.1
    • /
    • pp.121-129
    • /
    • 2007
  • The aim of this study is to investigate punching shear strength of exterior connections in the flat plate structure with rectangular column. To inspect the effect of column aspect ratios on the punching shear behavior, eight specimens for exterior connection were made and tested. In this experimental program the length of critical perimeter was kept constant, while column aspect ratio varied from 2.0 to 4.5. Two levels of concrete strength and slab reinforcement ratio were also considered. As the column aspect ratio increased, the punching shear strengths are decreased. The decrement of punching shear strength was small in specimens with high aspect ratio of column.

Estimation of Safety Factor for a Jointed Rack Slope by DEM (개별요소법에 의한 절리 암반사면의 안전율 평가)

  • 유광호;박연준
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.241-247
    • /
    • 2001
  • 절리가 발달한 암반사면의 경우, 토사사면의 안전율 평가를 위해 널리 이용되는 한계평형법을 이용한 해석법은 파괴 활동면을 가장할 수 없기 때문에 사용이 곤란하다. 한편, 비등방 탄소성 모델(편재절리모델)을 사용하여 2조의 절리군을 가진 암반사면의 안전율을 계산할 수 있는 방법이 개발되었지만, 이 방법은 개별절리를 효과적으로 고려하지 못한다. 본 연구에서는 개별절리를 고려한 불연속체 해석에 의한 암반사면의 안정성 해석시 사면의 안전율을 평가하는 기법을 개발하였다. 이를 위해, 절리 전단강도 감소기법을 적용하였으며, UEDC의 내장 언어인 FISH를 사용하여 프로그램을 개발하였다. 또한 실제 절리 암반사면을 대상으로 절리를 측정하고, 개발된 기법에 의한 사면의 안전율을 구하였으며, 동일한 사면에 대해 등가연속체로 가정한 편재절리모델 해석을 수행하여 결과를 비교하였다.

  • PDF