• Title/Summary/Keyword: 전단보강근

Search Result 102, Processing Time 0.023 seconds

Comtribution of surface deformations of GFRP rebar to bond to Concrete (GFRP 보강근 표면이형의 부착성능 기여도에 대한 고찰)

  • Moon, Do-Young;Sim, Jong-Sung;Oh, Hong-Seob;Sim, Jun-Gee;Kim, Jin-Gyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.19-20
    • /
    • 2009
  • Bond of deformed type of GFRP rebar, which has deformations resembles that of ordinary steel rebar, to concrete was investigated experimentally and numerically in this paper. Due to the lower stiffness and strength in shear, surface deformations do not fully works in bond with surrounding concrete. In this paper, the effective surface deformation height of GFRP rebar with ribs was determined based on experimental and numerical results.

  • PDF

An Experimental Study on the Shear Behavior of Reinforced Concrete Deep Beams Subject to Concentrated Loads (집중하중을 받는 철근콘크리트 깊은 보의 전단거동에 관한 실험적 연구)

  • Lee, Jin-Seop;Kim, Sang-Sik
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.191-200
    • /
    • 1999
  • The shear behavior of simply supported reinforced concrete deep beams subject to concentrated loads has been scrutinized experimentally to verify the influence of the structural parameters such as concrete strength, shear span-depth ratio, and web reinforcements. A total of 42 reinforced concrete deep beams with compressive strengths of 250 kg/$cm^2$ and 500 kg/$cm^2$ has been tested at the laboratory under one or two-point top loading. The shear span-depth ratio have been taken as three types of 0.4, 0.8 and 1.2, and the horizontal and vertical shear reinforcements ratio, ranging from 0.0 to 0.57 percent respectively. In the tests, the effects of the shear span-depth ratio, concrete strength and web reinforcements on the shear strength and crack initiation and propagation have been carefully checked and analyzed. From the tests, it has been observed that the failures of all specimens were due to shear and the shear behaviors of specimens were greatly affected by inclined cracks from the load application points to the supports in shear span. The load bearing capacities have changed significantly depending on the shear span ratio, and the efficiency of horizontal shear reinforcements were increased as the shear span-depth ratio decreased. The test results have been analyzed and compared with the formulas proposed by previous researchers and the design equation from the code. While the shear strengths obtained from the tests showed around 1.4 and 1.9 times higher than the values calculated by CIRIA guide and the domestic code, they were closely coincident with the formulas given by de Paiva's equation.

Experimental Study of Reinforced High-Strength Concrete Beams without Stirrups Considering Shear Behaviour (전단보강근이 없는 고강도 콘크리트 깊은 보의 전단특성 실험연구)

  • Yang, Seong-Hwan;Lee, Dong-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.4
    • /
    • pp.336-342
    • /
    • 2014
  • Shear strengths of reinforced high strength concrete beams without web reinforcement are studied with experimental analysis of 10 specimen with 2.4 shear span-to-depth ratio (a/d) beams for 4 stages of concrete compressive stength over 60MPa comparing ultimate loads and shear stresses of ACI363R and KCI code equations. Expecially, concrete compressive strengths used in shear design were essentially limited to 10,000 psi (69MPa) by ACI363R and KCI Code. The modified Code equation's shear stresses of the specimen without the limit are compared with test results. The comparison between the modified exist Code equations results and test results are expected to show an available scope to apply in construction field and to give considerations of design and contraction.

An Analysis of the Shear Strength of Reinforced Concrete Beams with Recycled Coarse Aggregates (순환굵은골재 철근 콘크리트 보의 전단강도 분석)

  • Ji, Sang-Kyu;Yun, Hyun-Do;Song, Seon-Hwa;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.851-854
    • /
    • 2008
  • Using the recycled aggregate not only saves landfill space but also reduces the demand for extraction of natural raw material for new construction activity. However few investigations have been carried out to study the shear behaviors of RC beams with recycled aggregates such as low absorption of recycled aggregate and full-scale specimens. In this study, six reinforced concrete beams were tested to evaluate the effects of shear strength, and shear behavior on the replacement level (0, 30, 60, and 100%) of recycled coarse aggregate and different amounts of shear reinforcement. The results showed that the beams with recycled coarse aggregates present the similar shear strength and deflections as the beam with natural aggregate on an equal amount of shear reinforcement. the reinforced concrete beams with recycled coarse aggregates present the Influence of shear span-to-depth ratio, effective depth, tension reinforcement ratio and compressive strength as the beams with natural aggregate. Shear strength were compared with the provisions in current code (KCI2007) and the equation proposed by Zsutty. The KCI equations were conservative and subsequently can be used for the shear design of recycled aggregate concrete beam.

  • PDF

Cyclic-Leading Tests of RC Exterior Beam-Column Joints with Non-Seismic Detailing (비내진 상세를 가진 RC 외부접합부의 반복 횡하중 실험)

  • Cha, Byung-Gi;Ko, Dong-Woo;Woo, Sung-Woo;Lee, Han-Seon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.11-16
    • /
    • 2003
  • The objective of this study is to clarify the seismic capacity and the characteristics in the hysteretic behavior of RC structures with non-seismic detailing. To do this, an exterior beam-column subassemblage was selected from a ten story RC building and six 1/3-scale specimens were manufactured with three variables; (1) with and without slab, (2) upward and downward direction of anchorage for the bottom bar in beams, and (3) with and without hoop bars in the joint region. The test results have shown that (1) the existence of slab increased the strength in positive and negative moment, 25% and 52%, respectively; (2) the Korean practice of anchorage (downward and 25 $d_{b}$ anchorage length) caused the 8% reduction of strength and the early strength degradation in comparison with the case of seismic details; and (3) the existence of hoop bars in the joint region shows significant role in preventing the pull-out.t.

Stress Distribution in Construction Joint of Prestressed Concrete Bridge Members with Tendon Couplers (고강도 철근콘크리트 보-기둥 외부 접합부의 전단 거동에 관한 실험)

  • Park Ki-Choul
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.535-542
    • /
    • 2005
  • Two series of experiments on the performance of beam-column joints in High-Strength Reinforced concrete frames were carried out. Main experimental parameters were : concrete strength, column axial load and amount of joint hoop reinforcement. Test result showed that the ultimate shear strength of exterior joints increased of column axial compressive force and the amount of the joint hoop reinforcements. Through the regression analysis on the 24data, the following equation is obtained $jv_u=(2.935{\times}10-3\;{\rho}jw{\cdot}fy\;+\;0.365){\sqrt{f_{ck}}}$

Optical Microscopic Image Analysis for Damaged GFRP Rebar by Alkali and High Temperature Exposures (알칼리와 고온노출에 의한 GFRP 보강근 손상에 대한 현미경분석 연구)

  • Bae, Jung-Myung;Moon, Do-Young;Park, Cheol-Woo;Park, Young-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.53-59
    • /
    • 2017
  • In this experimental study, the characteristic of damages on GFRP rebar exposed to high temperature only and immerged in alkaline solution after the exposure to high temperature was analyzed through microscopic image analysis. The found microcrack and pores in resin matrix were quantitatively compared if there was effect of pre-exposure to high temperature. The damages, such as microcrack and pores in resin matrix, by alkali exposure were mainly found in rebar surface. On the other hand, the pores caused by high temperatures were extensively found in a section and had greater width than those caused by the alkali exposure. In results of the quantitative comparison, the accumulated length and widths of microcrack and pores in resin matrix in pre-exposed GFRP rebar to high temperature were respectively 1.5 and 1.4 times of those in the GFRP rebar only immerged in alkali solution. Therefore, the deterioration of resin matrix by the alkali exposure could be accelerated due to the pre-exposure to high temperature.

Experimental Study for GFRP Reinforced Concrete Beams without Stirrups (스터럽이 없는 GFRP 보강근 콘크리트 보에 대한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.21-29
    • /
    • 2014
  • This paper evaluates the shear strength, behavior and failure mode of reinforced concrete beams with deformed GFRP reinforcing bar. Four concrete beam specimens were constructed and tested. It was carried out to observe failure behavior and load-deflection of simply supported concrete beams subjected to four-point monotonic loading. In order to eliminate of the uncertainty by the shear reinforcements, any stirrups were not used. Variables of the specimens were shear span-depth ratio, effective reinforcement ratio. The dimensions of specimen is 3,300 or $1,950mm{\times}200mm{\times}240mm$. Clear span and shear span were 2,900mm, 1,000mm respectively. Shear span-depth ratios were 6.5 and 2.5. Effective ratios of Longitudinal GFRP reinforcing bar were $1.126{\rho}_{fb}$, $2.250{\rho}_{fb}$, $3.375{\rho}_{fb}$ and $0.634{\rho}_{fb}$. All beam specimens were broken by diagonal-tension shear and the ACI 440.1R, CSA S806 and ISIS, which was used to design test beams, showed considerable deviation between prediction and test results of shear strengths.

Experimental Study on Shear Strength of AFRP-Reinforced Concrete Deep Beam (AFRP 보강근 콘크리트 깊은보의 전단강도에 대한 실험적 연구)

  • Cho, Jang-Se;Lee, Young-Hak;Kim, Hee-Cheul
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.445-448
    • /
    • 2010
  • 본 연구는 섬유 보강 폴리머(Fiber Reinforced Polymers, 이하 FRP) bar로 보강된 콘크리트 깊은 보의 전단강도를 평가하기 위하여 전단경간비, 보강비, 주근의 종류를 변수로 총 6개의 실험체에 대한 전단 실험을 수행하였다. 전단실험을 토대로 FRP bar로 보강된 콘크리트 깊은보의 균열 및 처짐에 대한 거동 조사를 수행하였으며, ACI 318-08의 스트럿-타이 모델을 이용한 전단강도와 아치작용을 고려한 기존 제안식에 의한 전단강도를 비교 평가하였다. 그 결과, FRP bar로 보강한 실험체와 철근으로 보강한 실험체는 상이한 전단거동을 보였으며, FRP bar로 보강한 경우의 전단강도가 철근으로 보강한 경우보다 증가하는 것으로 나타났다. 전단강도 산정에 있어서는 ACI 318-08의 스트럿-타이 모델을 이용한 방법이 기존 제안식에 의한 방법보다 상대적으로 정확했다.

  • PDF

Recommendations of Environmental Reduction Factor of FRP Rebar for Durability Design of Concrete Structure (콘크리트 보강용 FRP 보강근의 내구성 설계를 위한 환경영향계수의 제안)

  • Park Chan-Gi;Won Jong-Pil;Kang Joo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.529-539
    • /
    • 2004
  • The corrosion of steel rebars has been the major cause of reinforced concrete deterioration. FRP(Fiber-reinforced polymer) rebar has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. However, FRP rebar is prone to deteriorate due to other degradation mechanisms than those for steel. The high alkalinity of concrete, for instance, is a possible degradation source. Therefore, the USA, Japan, Canada, UK. etc are using environmental reduction factor. Although difference design guidelines were drawn in many, including USA, Japan, Canada, UK etc, recommendations and coefficients that could take into account the long-term behavior of FRP reinforcement were not well defined. This study focuses on recommendation of environmental reduction factor of FRP rebar. Environment reduction factor were decided using durability test result. FRP rebars were subjected to twelve type of exposure conditions including alkaline solution, acid solution, salt solution and deionized water etc. The water absorption behavior was observed by means of simple gravimetric measurements and durability properties were investigated by performing tensile, compressive and short beam tests. Based on the experimental result, environmental reduction factor of hybrid FRP rebar(A), and (C) and CFRP rebar was decided as 0.85. Also, hybrid FRP rebar(B) and GFRP rebar were decided as 0.7 for the environmental reduction factor