• Title/Summary/Keyword: 전기IT

Search Result 23,895, Processing Time 0.051 seconds

Correlation Analysis between Sasang Constitution and Oriental Pattern Identification by Using Oriental Diagnosis System (한의전문가시스템을 활용한 사상체질과 한의변증 간의 상관관계 분석)

  • Jo, Hye Jin;Noh, Yun Hwan;Cho, Young Seuk;Shin, Dong Ha;Kwon, Young Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.5
    • /
    • pp.255-260
    • /
    • 2019
  • Oriental Diagnosis System(ODS) is an artificial intelligence program that utilize entered diagnosis knowledge, determine patient's disease and decide right medicine. The purpose of this study is to find a correlation between pattern Identification in Korean medicine and each sasang types(So-Yang, So-Eum and Tae-Eum) by analyzing ODS diagnosis result. Eventually our study secure availability of using ODS program at clinical training or developing diagnosis program. Subject of this study is 32 students participating in Sasang medical practice(12 subjects were So-Yang, 7 subjects were So-Eum, and 13 subjects were Tae-Eum). We analyze subject's clinical practice result reports by using ODS program and obtained result about pattern Identification. We used SPSS statistics 23 in analyzing the differences of the scores of Eight Principle Pattern Identification, Qi-Blood Pattern Identification, Bing-xie Pattern Identification, and Visceral Pattern Identification in each Sasang types (So-Yang, So-Eum, Tae-Eum). In the case of Heat-moisture, Tae-Eum showed higher score than So-Eum, but So-Yang showed no difference from the other two Sasang types(p<0.05). And in the case of Food-accumulation, Tae-Eum and So-Yang showed significantly higher score than So-Eum(p<0.05). It is hard to generalize the result because subject of this study was not enough. However, we explained correlation between pattern Identification in korean medicine and each sasang types based on quantifiable and objective evidence system. Therefore use of ODS program in student clinical practice training help to understand the relationship and correlation between different pattern Identification and will help standardization of clinical practice education.

Influence of Gd0.1Ce0.9O2-δ Interlayer between La0.6Sr0.4Co0.2Fe0.8O3-δ Cathode and Sc-doped Zirconia Electrolyte on the Electrochemical Performance of Solid Oxide Fuel Cells (La0.6Sr0.4Co0.2Fe0.8O3-δ 공기극과 Sc이 도핑된 지르코니아 전해질 사이에 삽입한 Gd0.1Ce0.9O2-δ 중간층이 고체산화물 연료전지의 전기화학적 성능에 미치는 영향)

  • Lim, Jinhyuk;Jung, Hwa Young;Jung, Hun-Gi;Ji, Ho-Il;Lee, Jong-Ho
    • Ceramist
    • /
    • v.21 no.4
    • /
    • pp.378-387
    • /
    • 2018
  • The optimal fabrication conditions for $Gd_{0.1}Ce_{0.9}O_{2-{\delta}}$(GDC) buffer layer and $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ (LSCF) cathode on 1mol% $CeO_2-10mol%\;Sc_2O_3$ stabilized $ZrO_2$ (CeScSZ) electrolyte were investigated for application of IT-SOFCs. GDC buffer layer was used in order to prevent undesired chemical reactions between LSCF and CeScSZ. These experiments were carried out with $5{\times}5cm^2$ anode supported unit cells to investigate the tendencies of electrochemical performance, Microstructure development and interface reaction between LSCF/GDC/CeScSZ along with the variations of GDC buffer layer thickness, sintering temperatures of GDC and LSCF were checked, respectively. Electrochemical performance was analyzed by DC current-voltage measurement and AC impedance spectroscopy. Microstructure and interface reaction were investigated by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). Although the interfacial reaction between these materials could not be perfectly inhibited, We found that the cell, in which $6{\mu}m$ GDC interlayer sintered at $1200^{\circ}C$ and LSCF sintered at $1000^{\circ}C$ were applied, showed good interfacial adhesions and effective suppression of Sr, thereby resulting in fairly good performance with power density of $0.71W/cm^2$ at $800^{\circ}C$ and 0.7V.

Design and Implementation of the Customized Contents Organization Engine (맞춤형 콘텐츠 구성 엔진의 설계 및 구현)

  • Heo, Sun-Young;Kim, Eun-Gyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.599-601
    • /
    • 2009
  • In currently being adopted as a e-leaning standard, SCORM it is difficult to provide the customized contents to a learner by changing the learner's level at runtime, and to control selective studying. So, we designed and implemented the customized contents organization engine(CCOE) in order to complement SCORM's faults in this paper. The CCOE consists of a level evaluation module, a contents re-organization module and a question item selection module. A level evaluation module evaluates the learner's level based on a question item reaction theory. And a question item selection module selects some random items by each level or by considering the learner's level which is then provided to a studying before evaluation, a section evaluation, and a quiz. And then this module transmits the selected items to the contents reorganization module for providing the quiz. A contents re-organization module selects the customized contents based on the learner's level by searching the tagged difficulty to the content, and creates the sequence with the selected items and the transmitted items from the question item selection module. If proposed in this paper CCOE is applied, the higher effectiveness of learning is expected by providing the customized learning contents based on the re-evaluated learner's level by each section.

  • PDF

Trend Analysis using Topic Modeling for Simulation Studies (토픽 모델링을 이용한 시뮬레이션 연구 동향 분석)

  • Na, Sang-Tae;Kim, Ja-Hee;Jung, Min-Ho;Ahn, Joo-Eon
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.3
    • /
    • pp.107-116
    • /
    • 2016
  • The recent diversification in terms of the scope and techniques used for simulations has highlighted the importance of analyzing state of the art trends and applying these for educational and study purposes. While qualitative methods such as literature research or experts' assessments have previously been used, such methods are in fact likely to reflect the subjective viewpoint of experts, and to involve too much time and money for the results obtained. For the purpose of an objective analysis, a quantitative analysis that included the examination of topics found in domestic academic journal articles was conducted in the present study. In this regard, simulation was found to be most actively used domestically in the electrical and electronic fields. In addition, simulation was also found to be employed for the purpose of education and entertainment in the social sciences. The results of this study are expected to help to facilitate the prediction of the direction of the development of not only the Korea Society for Simulation, but also domestic simulation studies. This study also raises the possibility of applying text mining to trend analysis, and proves that it can be a useful method for deriving future key topics and helping experts' decisions regarding quantitative data.

Electrical Characteristics of PV Modules with Odd Strings by Arrangement on Bypass Diode (홀수스트링 PV모듈의 바이패스 다이오드 배치에 의한 전기적 특성)

  • Shin, Woo-Gyun;Go, Seok-Hwan;Ju, Young-Chul;Song, Hyung-Jun;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.1-11
    • /
    • 2017
  • Most PV modules are fabricated by 6 cell-strings with solar cells connected in series. Moreover, bypass diodes are generally installed every 2 cell-strings to prevent PV modules from a damage induced by current mismatch or partial shading. But, in the case of special purpose PV module, like as BIPV (Building Integrated Photovoltaic), the number of cell-strings per module varies according to its size. Differ from a module employing even cell-strings, the configuration of bypass diode should be optimized in the PV module with odd strings because of oppositely facing electrodes. Hence, in this study, electrical characteristics of special purposed PV module with odd string was empirically and theoretically studied depending on arrangement of bypass diode. Here, we assumed that PV module has 3 strings and the number of bypass diodes in the system varies from 2 to 6. In case of 2 bypass diodes, shading on a center string increases short circuit current of the module, because of a parallel circuit induced by 2 bypass diodes connected to center string. Also, the loss is larger, as the shading area in the center string is enlarged. Thus, maximum power of the PV module with 2 bypass diode decreases by up to 59 (%) when shading area varies from 50 to 90 (%). On the other hand, In case of 3 and 6 bypass diodes, the maximum power reduction was within about 3 (W), even the shading area changes from 50 to 90 (%). As a result, It is an alternative to arrange the bypass diode by each string or one bypass diode in the PV module in order to completely bypass current in case of shading, when PV module with odd string are fabricated.

Growth Characters and Vegetation Survey in Natural Habitat of Dicentra spectabilis (L.) Lem (금낭화의 생육특성 및 자생지 식생조사)

  • Heo, Kwon;Lee, Chae-Gon;Jang, Min-Young;Cho, Dong-Ha;Yoo, Chang-Yeon
    • Korean Journal of Plant Resources
    • /
    • v.13 no.3
    • /
    • pp.188-194
    • /
    • 2000
  • This study was carried out to obtain the optimum cultivation conditions of wild ornamental plant resources, Dicentra spectabilis L. The altitude of the habitat was ranged from 630m to 690m in Mt. Gujeol. Most of the habitat faced toward the northeast aspect and the gradient was ranged from 25 to 33 degrees. The light intensity of Dicentra community was 14,000lux on the average, and it was tendency to decrease by foliation of other woody plants. The appearance number of Dicentra per quadrat was 30 individuals on the average, and total appearance species in all quadrat surveyed was 52 taxa. Among them, Quercus mongolica, Lindera obtusiloba, Corylus heterophylla, Cornus controversa, woody plants, Corydalis speciosa, Pseudostellaria heterophylla, Artemisia keiskeana, Dryopteris crassirhizoma, Arisaema amurense var. serratum, Carex siroumensis, and Chloranthus japonicus, herbaceous plants, were showed as dominant species. Soil acidity in the habitat was 5.15 to 5.96, and average content of soil moisture was 32.6%. The contents of average organic matter, $P_2O_5$, K, Ca, and Mg were 1.99%, 14mg/kg, 0.55me/100g, 15.2me/100g, and 3.3me/100g, respectively. Electron conductivity was ranged from 0.50 to 0.76dS/m. Also, the average air temperature of May and June was 14.2$^{\circ}C$ and 19.4$^{\circ}C$, respectively.

  • PDF

Selection of Low Pathogenic Variety in Bacillus thuringiensis to Silworm, Bombyx mori (누에에 대한 저독성 Bacillus thuringiensis 균근의 선발)

  • Kim, Cheol-Yeong;Kim, Yeong-Hun;Gang, Seok-Gwan
    • Journal of Sericultural and Entomological Science
    • /
    • v.28 no.1
    • /
    • pp.43-53
    • /
    • 1986
  • Among many microbial pesticides, Bacillus thuringiensis is one of the most hopeful pesticide and some commercial products have been appearing on the market. Because these commercial products contain living spores and toxins of the organism, there is a danger that living spores of B. thuringiensis may be scattered by wind and cause a great damage in the sericulture areas. In order to avoide these risks it is desirable to select the strain which has low pathogenicity to the silkworm, and at the sometime being highly pathogenic to the pest insects. Thus this study has been carried out to acquire some basic informations about the procedure of desicable strain selection. Three strains of B. thuringiensis var. kurstaki, var. dendrolimus and var. aizawai were used for the pathogenicity test on the silkworm, Bombux mori and the fall webwarm, Hyphantria cunea. Those strains were investigated by the agarose gel electrophoresis patterns of plasmid DNA determine whether mutation had occured. Pathogenicity tests were carried out of using isolated crystal proteins and spore-crystal protein to mixtures of each strain, seperatively. In case of using spore-crystal protein mixture, the order of pathogenicity in varities of B. thuringiensis against B.mopri and H.cunea were kurstaki, aizawai, dendrolimus and kurstaki, dendrolimus, aizawai, respectively. But using isolated crystal proteins, dendrolimus had the highest toxicity to H. cunea and the lowest toxicity to B. mori among tested three strains. From the above results, dendrolimus was presumed the most desirable straing for using microbial pesticide.

  • PDF

Changes in the girth of anthropometric variables during menstrual cycle in women university students (여자대학생의 생리주기에 따른 인체계측변인 둘레의 변화)

  • Kim, Young-Sun;Kang, Seol-Hee;Kim, Yun-Jung;Park, Won-Yeop;Jang, Jee-Hun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.421-429
    • /
    • 2021
  • The purpose of this study was to identify the change in the girth of anthropometric variables during menstrual cycle, and to provide basal data for health promotion program development during pre-menstrual phase and menstrual phase. Participants were 10 healthy women university students without menstrual irregularity, subjective premenstrual syndrome, premenstrual dysphoric disorder, dymenorrhea, obstetrician and gynecologic disease. Chest girth(axillary and papillary), waist girth(half point between iliac crest and 12th rib, and navel), and hip girth were repeatedly measured in menstrual phase, follicular phase, luteal phase during single menstrual cycle. As a result, axillary chest girth in menstrual phase was significantly increased than that in luteal phase. Papillary chest girth and waist girth at half point between iliac crest and 12th rib in menstrual phase were significantly increased than those in follicular phase. No significance was shown in chest and waist girth between follicular and luteal phase. No significance was shown in hip girth during menstrual cycle. In conclusion, signicant difference was shown in chest and waist girth during menstrual cycle. And it is suggested that succeeding research should be carried out with reference to body weight, body fat, blood and local hormone concentration during menstrual cycle.

Effect of SUS316L Bipolar Plate Corrosion on Contact Resistance and PEMFC Performance (SUS316L 분리판 부식에 의한 접촉저항 및 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.664-670
    • /
    • 2021
  • Stainless steel was applied as bipolar plate (BP) of polymer electrolyte membrane fuel cell (PEMFC) due to high mechanical strength, electrical conductivity, and good machinability. However, stainless steel was corroded and increased contact resistance resulting PEMFC performance decrease. Although the corrosion resistance could be improved by surface treatment such as noble metal coating, there is a disadvantage of cost increase. The stainless steel corrosion behavior and passive layer influence on PEMFC performance should be studied to improve durability and economics of metal bipolar plate. In this study, SUS316L bipolar plate of 25 cm2 active area was manufactured, and experiments were conducted for corrosion behavior at an anode and cathode. The influence of SUS316L BP corrosion on fuel cell performance was measured using the polarization curve, impedance, and contact resistance. The metal ion concentration in drained water was analyzed during fuel cell operation with SUS316L BP. It was confirmed that the corrosion occurs more severely at the anode than at the cathode for SUS316L BP. The contact resistance was increased due to the passivation of SUS316L during fuel cell operation, and metal ions continuously dissolved even after the passive layer formation.

Air Density Measurement in a Narrow Test Section Using a Laser Absorption Spectroscopy (레이저 흡수 분광법을 사용한 좁은 시험 구간 내 공기 밀도 측정)

  • Shim, Hanseul;Jung, Sion;Kim, Gyeongrok;Park, Gisu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.11
    • /
    • pp.893-900
    • /
    • 2021
  • In this study, air density in a narrow test section is measured using a laser absorption spectroscopy system that detects oxygen absorption lines. An absorption line pair at 13156.28 and 13156.62 cm-1 are detected. A gas chamber with a height of 40 mm is used as a narrow test section. A triangular spiral-shaped laser path is applied in the gas chamber to amplify absorption strength by extending laser beam path length. A well-known logarithm amplifier and a secondary amplifier are used to electrically amplify absorption signal. An AC-coupling is applied after the logarithm amplifier for signal saturation prevention and noise suppression. Procedure of calculating spectral absorbance from output signal is introduced considering the logarithm amplifier circuit configuration. Air density is determined by fitting the theoretically calculated spectral absorbance to the measured spectral absorbance. Test conditions with room temperature and a pressure range of 10~100 kPa are made in a gas chamber using a Bourdon pressure gauge. It is confirmed that air density in a narrow test section can be measured within a 16 % error through absorption signal amplification using a triangular spiral-shaped beam path and a logarithm amplifier.