• Title/Summary/Keyword: 전기IT기기

Search Result 715, Processing Time 0.163 seconds

Battery Pack of Elastically Adhering Protection Circuit Module (보호회로가 탄성적으로 부착된 전지 팩)

  • Cho, Kyeung-Ho;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1740-1749
    • /
    • 2009
  • As mobile devices evolve and digital convergence trend is here to stay, mobile phones are built with multiple functions including cameras, MP3s, TVs and game consoles. As a consequence, such multi-functional mobile phones come to spend more power, facilitating development of next-generation ultra-capacity lithium ion battery. In addition, environmental regulations and rising oil prices cause demand for hybrid cars to keep rising. Accordingly, more and more attention is being paid to medium and large batteries and more efforts are being made to realize lower battery prices, higher outputs and stability. This study presented a patent technology related to the lithium ion battery packing that allows reducing processes related, increasing productivity and recycling parts other than the body. The lithium ion battery pack to which protection circuits are elastically attached provides short circuit protection for the circuit and the body and makes electric connection of the circuit and the body easier.

A Study on the Improved Ignition Limit with Resistor for Propan-air Mixture Gas (저항을 이용한 프로판-공기 혼합가스의 점화한계 개선에 관한 연구)

  • 이춘하;오종용;옥경재;지승욱;이광식;심광렬
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 2004
  • This paper describes the minimum ignition limits for propane-air 5.25 Vol.% mixture gases in low voltage inductive circiuts. The improved effects on the ignition limit are studied by parallel safety components(resistors) for propane-air 5.25 Vol.% mixture gas in low voltage inductive circuits. The experimental devices used in this test are the IEC type spark ignition test apparatus. The minimum ignition limits are controlled by the values of current in inductive circuit. Energy supplied from electric source is first accumulated at the inductance, it's extra energy is working as ignition source of the explosive gas. The improved effects on the ignition limit are respectively obtained as the maximum rising rate of 330% by composing parallel circuits between inductance and resistor as compared with disconnecting inductance with the safety components. The more values of inductance increase the higher improved effects of ignition limit rise. The less values of resistor the higher improved effects of ignition limit rise. It is considered that the result can be used for not only data for researches and development of intrinsically safe explosion-proof machines which are applied equipment and detectors used in dangerous areas but also for datum for its equipment tests.

A Study for Examples of Fire including with Combustible Substance and electrical overload in Automotive Inside Room (자동차 실내 인화성물질과 전기과부하에 의한 화재관련 사례 연구)

  • Han, Jae Oh;Ham, Sung Hoon;Lim, Ha Young;Lee, Il Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.38-43
    • /
    • 2014
  • This paper is to analyze and study the failure examples of fire by inflammables and electric contact faulty in interior of vehicle. The first example, the driver used to air freshener that remove the air conditioner bad smell. He get out of a car. And then, he put it on the crash pad. Before long, a fire breaks out because of explosion solar radiation. The second example, the driver used in room of a car. It certified the fire by disconnection phenomenon happened the electric overload. The third example, the driver install the heat rays to warm his body, In the initial stages, it didn't seek the dangerous of fire during using a car to 5,000km. This heat rays become to down durability so that produced the electric overload in an instant. The fourth example, after the man smoked the cigarette on riding with rear seat, he put it on seat in vehicle no extinguishing the burning cigarette. It knew the fact that burnt to ashes a car by on well combustible paper. Thus, the driver must consider a countermeasure for minimize the fire production when he use the inflammable and install adding electric system.

Improving Code Coverage for the FPGA Based Nuclear Power Plant Controller (FPGA기반 원전용 제어기 코드커버리지 개선)

  • Heo, Hyung-Suk;Oh, Seungrohk;Kim, Kyuchull
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.305-312
    • /
    • 2014
  • IIt takes a lot of time and needs the workloads to verify the RTL code used in complex system like a nuclear control system which is required high level reliability using simple testbench. UVM has a layered testbench architecture and it is easy to modify the testbench to improve the code coverage. A test vector can be easily constructed in the UVM, since a constrained random test vector can be used even though the construction of testbench using UVM. We showed that the UVM testbench is easier than the verilog testbench for the analysis and improvement of code coverage.

A Fully Programmable Shader Processor for Low Power Mobile Devices (저전력 모바일 장치를 위한 완전 프로그램 가능형 쉐이더 프로세서)

  • Jeong, Hyung-Ki;Lee, Joo-Sock;Park, Tae-Ryong;Lee, Kwang-Yeob
    • Journal of IKEEE
    • /
    • v.13 no.2
    • /
    • pp.253-259
    • /
    • 2009
  • In this paper, we propose a novel architecture of a general graphics shader processor without a dedicated hardware. Recently, mobile devices require the high performance graphics processor as well as the small size, low power. The proposed shader processor is a GP-GPU(General-Purpose computing on Graphics Processing Units) to execute the whole OpenGL ES 2.0 graphics pipeline by using shader instructions. It does not require the separate dedicate H/W such as rasterization on this fully programmable capability. The fully programmable 3D graphics shader processor can reduce much of the graphics hardware. The chip size of the designed shader processor is reduced 60% less than the sizes of previous processors.

  • PDF

Computation of Critical Length for Linear Grounding Electrodes (직선형 접지전극의 임계길이의 산정)

  • Kim, Ki-Bok;Lee, Bok-Hee;Joe, Jeong-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.67-74
    • /
    • 2009
  • For the surge currents like lightning currents containing high frequency components and the abnormal currents having high frequencies which cause the EMI(Electromagnetic interference) problems for the electronic devices and communication instruments, the linear grounding electrodes have the significantly composite impedance characteristics which are dependent on the frequency of the applied current. The impedance of a grounding electrode is not lowered by expanding the dimension of the grounding electrode, and the length of grounding electrode having the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical length. In this paper, the critical lengths for the vertically and horizontally-buried grounding electrodes are calculated by using the distributed parameter circuit model. The propriety of the simulations has been confirmed by comparing the simulated results with the measured results.

Thermal Runaway Prevention of MOV and Safety Improvement of Power Line System and Internal Electronic Device Circuit Using a Phosphorous Switching Module (인청동 스위칭 모듈을 이용한 전력계통 및 전자기기 내부회로의 MOV 열폭주 방지와 안전성 개선)

  • Kim, Ju-Chul;Choi, Gyung-Ray;Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.75-79
    • /
    • 2011
  • The MOV(Metal Oxide Varistor), a voltage limiting element, has been installed in the SPD(Surge Protective Device) or inside the internal circuit of an electronic appliance for protection of the electric power system and electronic device against electrical surge. Such an MOV is exposed, however, to the risk of the thermal runaway resulting from excessive voltage and deterioration. In this paper, a reciprocal action has been tested and analyzed using a phosphorus bronze switching module and the low-temperature solder. And a short current break characteristic test linked with the circuit breaker has been performed to limit the inrush current when the MOV breaks down. It has been proven that the phosphorus bronze switching module installed inside the internal circuit can improve the safety of the power line system and the electronic device.

The Feature Extraction of Partial Discharge Electromagnetic Wave utilizing Signal Processing Techniques (신호처리 기술에 의한 부분방전 방사전자파의 특징 추출)

  • 이현동;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2002
  • In recent years, diagnostic techniques have been investigated to detect a partial discharge(PD) in a high voltage electrical equipment. Because PD signal is very sensitive and difficult to suppress strong noises such as narrow-band radio frequency noise and random noise, the accuracy and credibility of PD measurement might be influenced by surrounding interference. Using the technique of PD detection by electromagnetic wave, we have studied the characteristics of both PD and substation-in interference signal. Also, we propose a wavelet packet transform based technique to perform a feature extraction from the interference and PD signal and a classification of the extracted features. The results show that time-frequency characteristics between PD and interference can be obviously distinguished. It is helpful for the development of the insulation diagnosis technique.

A thermal stability testing and analysis for a surge protector installed in residential distribution board (주택용 분전반에 설치되는 서지보호기의 열적 안전성 시험 및 분석)

  • Kim, Ju-Chul;Park, Jang-Bum;Ki, Che-Ouk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.339-341
    • /
    • 2009
  • Surge Protective Device(SPD) is installed by increasing information and communication equipments and home network equipments by individual home, and the amount of SPD used is increasing by revision industry regulations and strengthening equipotential grounding system. Parts of SPD installed in residential distribution board has ZnO varistor, voltage constraint type devices, but it is exposed to Temporary Overvoltage Characteristic. This thesis analyzes products through Thermal Stability test for SPD for general house and suggests the better method. As results of analysis, Gas Discharge Tube(GDT) to cut off from a leakage current and more than two kinds of safety devices to protect Thermal Runaway were needed.

  • PDF

Reliability-Centered Maintenance Model for Maintenance of Electric Power Distribution System Equipment (배전계통 기기 유지보수를 위한 RCM 모델)

  • Moon, Jong-Fil;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.410-415
    • /
    • 2009
  • With the implementation of electric power industry reform, the utilities are looking for effective ways to improve the economic efficiency. One area in particular, the equipment maintenance, is being scrutinized for reducing costs while keeping a reasonable level of the reliability in the overall system. Here the conventional RCM requires the tradeoff between the upfront maintenance costs and the potential costs of losing loads. In this paper we describe the issues related to applying so-called the "Reliability-centered Maintenance" (RCM) method in managing electric power distribution equipment. The RCM method is especially useful as it explicitly incorporates the cost-tradeoff of interest, i.e. the upfront maintenance costs and the potential interruption costs, in determining which equipment to be maintained and how often. In comparison, the "Time-based Maintenance" (TBM) method, the traditional method widely used, only takes the lifetime of equipment into consideration. In this paper, the modified Markov model for maintenance is developed. First, the existing Markov model for maintenance is explained and analyzed about transformer and circuit breaker, so on. Second, developed model is introduced and described. This model has two different points compared with existing model: TVFR and nonlinear customer interruption cost (CIC). That is, normal stage at the middle of bathtub curve has not CFR but the gradual increasing failure rate and the unit cost of CIC is increasing as the interruption time is increasing. The results of case studies represent the optimal maintenance interval to maintain the equipment with minimum costs. A numerical example is presented for illustration purposes.