• Title/Summary/Keyword: 전기 화학적 부식

Search Result 350, Processing Time 0.028 seconds

Investigation on Electrochemical Characteristics of Battery Housing Material for Electric Vehicles in Solution Simulating an Acid Rain Environment with Chloride Concentrations (산성비 환경을 모사한 수용액에서 염화물 농도에 따른 전기자동차 배터리 하우징용 재료의 전기화학적 특성 연구)

  • Shin, Dong-Ho;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.147-157
    • /
    • 2022
  • Electrochemical characteristics and damage behavior of 6061-T6 aluminum alloy used as a battery housing material for electric vehicles were investigated in solution simulating the acid rain environment with chloride concentrations. Potentiodynamic polarization test was performed to analyze electrochemical characteristics. Damage behavior was analyzed through Tafel analysis, measurement of damage area, weight loss, and surface observation. Results described that corrosion current density was increased rapidly when chloride concentration excceded 600 PPM, and it was increased about 7.7 times in the case of 1000 PPM compared with 0 PPM. Potentiodynamic polarization experiment revealed that corrosion damage area and mass loss of specimen increased with chloride concentrations. When chloride concentration was further increased, the corrosion damage area extended to the entire surface. To determine damage tendency of pitting corrosion according to chloride concentration, the ratio of damage depth to width was calculated. It was found that the damage tendency decreased with chloride concentrations. Thus, 6061-T6 aluminum alloy damage becomes larger in the width direction than in the depth direction when a small amount of chloride is contained in an acid rain environment.

마그네트론 스퍼터링에 의해 제조된 CrAlSiN 박막의 화학성분에 따른 온도저항계수와 미세구조

  • Mun, Seon-Cheol;Ha, Sang-Min;Kim, Sang-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.100-102
    • /
    • 2013
  • Magnetron-sputtering법을 사용하여 기존에 연구하였던 CrAlN (Cr 7:Al 3)박막에 Si를 첨가하여 Si의 함량 변화에 따라 미세구조와 화학적 결합상태, 온도저항계수(TCR) 및 산화저항의 영향과 기계적특성 개선을 통한 multi-functional heater resistor layer로써의 가능성을 연구하였다. CrAlSiN 박막의 Si 함량에 변화에 따라 온도저항계수 변화를 확인하였으며 X-선 회절 분석(XRD) 패턴 분석결과 CrAlSiN 박막의 결정구조가 Bl-NaCl 구조를 가지고 있는 것을 확인하였으며 SEM과 AFM을 통한 표면 및 미세구조 분석결과 Si의 함량이 증가할수록 입자가 조밀해짐을 알 수 있었다. 최근 digital priting technology의 핵심 기술로 부각되고 있는 inkjet priting technology는 널리 태양전지뿐만 아니라 thin film process, lithography와 같은 반도체 공정 기술에 활용 할 수 있기 때문에 반도체 제조장비에도 사용되고 있으며, 현재 thermal inkjet 방식을 사용하고 있다. Inkjet printing technology는 전기 에너지를 잉크를 배출하기 위해 열에너지로 변환하는 thermal inkjet 방식을 사용하고 있는데, 이러한 thermal inkjet 방식은 기본적으로 전기저항이 필요하지만 electrical resistor layer는 잉크를 높은 온도에서 순간적으로 가열하기 때문에 부식이나 산화 등의 문제가 발생할 수 있어 이에 대한 보호층을 필요로 한다. 하지만, 고해상도, 고속 잉크젯 프린터, 대형 인쇄 등을 요구되고 있어 저 전력 중심의 잉크젯 프린터의 열효율을 방해하는 보호층 제거에 필요성이 제기되고 있다. 본 연구는 magnetron-sputtering을 사용하여 기존의 CrAlN 박막에 Si를 합성하여 anti-oxidation, corrosion resistance 그리고 low temperature coefficient of resistance 값을 갖는 multi-functional heater resistor layer로써 CrAlSiN 박막의 Si 함량에 따른 효과에 초점을 두었다. 본 실험은 CrAlN 박막에 Si 함량을 4~11 at%까지 첨가시켜 함량의 변화에 따른 특성변화를 확인하였다. 함량이 증가할수록 amorphous silicon nitride phase의 영향으로 박막의 roughness는 감소하였으며 XRD 분석결과 (111) peak의 Intensity가 감소함을 확인하였으며 SEM 관찰시 모든 박막이 columnar structure를 나타내었으며 Si함량이 증가할수록 입자가 치밀해짐을 보여주었다.Si함량이 증가할수록 CrAlN 박막에 비하여 면저항은 증가하였으며 TCR 측정결과 Si함량이 6.5 at%일 때 가장 안정한 TCR값을 나타내었다. Multi-functional heater resistor layer 역할을 하기 위해서, CrAlSiN 박막의 원소 분포, 표면 거칠기, 미세조직, 전기적 특성 등을 조사하였다. CrAlN 박막의 Si의 첨가는 크게 XRD 분석결과 주상 성장을 억제 할 수 있으며 SEM 분석을 통하여 Si 함량이 증가할수록 Si3N4 형성이 감소하며 입자크기가 작아짐을 확인하였다. 면저항의 경우 Si 함량이 증가함에 따라 높은 면저항을 나타내었으며 Si함량이 6.5 at%일 때 가장 낮은 TCR 값인 3120.53 ppm/K값을 보였다. 이 값은 상용되고 있는 heater resistor보다 높지만, CrAlSiN 박막이 더 우수한 기계적 특성을 가지고 있기 때문에 hybrid heater resistor로 적용할 수 있을 것으로 기대된다.

  • PDF

A Study on the Sterilization Effect of Ballast Water according to the Combination of Types of Treatment Apparatus (선박평형수 처리장치의 조합에 따른 살균효과에 관한 연구)

  • Kang, Ah-Young;Kim, Sang-Pil;Song, Ju-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.412-417
    • /
    • 2015
  • The purpose of this study is to treat the ballast water by shear stress without an environmental pollution and to find out the optimal treatment conditions. The ballast water problem is issued up as the trade activated and the cargos mobilized. To improve this problem, International Marine Organization(IMO) make the rule about the ballast water treatment with specific restrictions. Although many countries have been studying about the ballast water treatment technology, there is almost no technology that can treat the microorganisms under $50{\mu}m$ without any secondary pollution. In this study, we tried to treat ballast water by applying shear stress as the physical treatment for the sterilization and tried to find out the optimal conditions including the 100% sterilizing rate and the best economic condition.

Comparison of Catalyst Support Degradation of PEMFC Electrocatalysts Pt/C and PtCo/C (PEMFC 전극촉매 Pt/C와 PtCo/C의 촉매 지지체 열화비교)

  • Sohyeong Oh;Yoohan Han;Minchul Chung;Donggeun Yoo;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.341-347
    • /
    • 2023
  • In PEMFC, PtCo/C alloy catalysts are widely used because of good performance and durability. However, few studies have been reported on the durability of carbon supports of PtCo/C evaluated at high voltages (1.0~1.5 V). In this study, the durability of PtCo/C catalysts and Pt/C catalysts were compared after applying the accelerated degradation protocol of catalyst support. After repeating the 1.0↔1.5V voltage change cycles, the mass activity, electrochemical surface area (ECSA), electric double layer capacitance (DLC), Pt dissolution and the particle growth were analyzed. After 2,000 cycles of voltage change, the current density per catalyst mass at 0.9V decreased by more than 1.5 times compared to the Pt/C catalyst. This result was because the degradation rate of the carbon support of the PtCo/C catalyst was higher than that of the Pt/C catalyst. The Pt/C catalyst showed more than 1.5 times higher ECSA reduction than the PtCo/C catalyst, but the corrosion of the carbon support of the Pt/C catalyst was small, resulting in a small decrease in I-V performance. In order to improve the high voltage durability of the PtCo/C catalyst, it was shown that improving the durability of the carbon support is essential.

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

Electrochemical Evaluation of Corrosion Properties of Aluminum Alloy as a Sacrificial Anode for Offshore Structure Protection (해양구조물의 방식을 위한 알루미늄 합금의 희생양극적 부식 특성의 전기화학적 평가)

  • Rhee, Jin-Ho;Lee, Jae-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.2
    • /
    • pp.68-72
    • /
    • 2015
  • The corrosion behavior of metals and alloys for the safety of offshore structures in seawater was investigated for the application of sacrificial anodes. The experiments were focused on the polarization behaviors and the surface morphology of each metal after experiments. Pure Zn, pure Al (Al1050), Al alloys (Al5052, Al6061), Mg alloys (AZ31, AZ91D) and steel (SCM440) were assessed in 3.5% sodium chloride solution by means of potentiodynamic polarization to verify the galvanic corrosion potential ($E_{couple}$). Potentiostat plots were plotted to compare the surface and corrosion current density ($i_{couple}$) of metals as sacrificial anodes in seawater to protect steel alloy as a cathode. Al alloys showed the best performance as a sacrificial anode, on the other hand, Mg alloys showed overprotection behavior. The surface morphologies of sacrificial anodes were observed by FESEM and compared.

Experimental study on the electrochemical properties of zwitterion and phosphate-based hybrid inhibitors in reinforced concrete (양쪽성 이온 및 인산염 기반 하이브리드 방청제의 전기화학적 특성에 관한 실험적 연구)

  • Tran, Duc Thanh;Jeong, Min-goo;Lee, Han-seung;Yang, Hyun-min;Singh, Jitendra Kumar
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.37-38
    • /
    • 2022
  • During the past decades, the corrosion of the steel rebar embedded in concrete structure surrounding marine environment is actually problematic and required the suitable preventive method. An eco-friendly corrosion inhibitor mix is investigated to stifle the active corrosion in comparison with other commercial corrosion inhibitors. The hybrid inhibitor enhances the corrosion resistance and the workability of concrete. However, it reduces the compressive strength slightly after 28-day-age. The electrochemical studies and mechanical studies are pointed out the corrosion resistance property, corrosion kinetics, and the mechanical properties of all concrete samples. H-3 is the optimum dose of hybrid inhbitor that meets the demand of both electrochemical property and mechanical property. It performs the noble features due to the formation of optimum amount of P-Zwitterions-(Cl)-Fe complex onto the steel rebar surface.

  • PDF

An Electrochemical Evaluation of the Corrosion Property on the Welded Zone of Sea Water Pipe according to Welding Materials (용접 재료 별 해수 배관 용접부위의 부식 특성에 관한 전기화학적 평가)

  • Kim, Jin-Gyeong;Won, Chang-Uk;Jo, Hwang-Rae;Lee, Myung-Hoon;Kim, Yun-Hae;Moon, Kyung-Man
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.5
    • /
    • pp.39-46
    • /
    • 2007
  • The sea water pipe of a ship's engine room is a severely corrosive environment caused by fast flawing sea water containing chloride ions and high conductivity. Therefore, leaking of sea water may occur as a result of local corrosion of the welded zone. Leaking is usually controlled by various welding methods. In this study, when the sea water pipe is welded with certain welding methods and welding electrodes, the corrosion resistance of WM (Welding metal) and HAZ (Heat affected zone) was investigated using electrochemical methods. Although the corrosion potential of the HAZ is higher than that of WM, the corrosion resistance of WM is superior to HAZ. However, when WM and HAZ are both opened to the sea water, the WM part with the anode was more seriously corroded than was the HAZ of the cathode by performance of a galvanic cell due to difference of the corrosion potential between HAZ and WM. In particular TIG welding showed relatively good results in corrosion resistance of both HAZ and WM compared to other welding methods.

Properties Investigation of Corrosion Monitoring for Pure Mg Thin Films under Wet-Dry Cyclic Conditions by Using Electrochemical Impedance Spectroscopy Method (건습환경중 순 Mg박막의 EIS부식 모니터링 특성 관찰)

  • Bae, I.Y.;Lee, K.H.;Kim, K.J.;Moon, K.M.;Lee, M.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.192-193
    • /
    • 2005
  • Magnesium thin films were prepared on cold-rolled steel substrates by RF(Radio Frequency) magnetron sputtering technique.$^{1)}$ The crystal orientation and monitoring of the deposited films were investigated by using XRD(X-ray Diffraction) and EIS(Electrochemical Impedance Spectroscopy), respectively. The corrosion rates of Mg thin films deposited with different argon gas pressure and substrate bias voltage were monitored by AC impedance method under a cyclic wet-dry condition, which was conducted by exposure to alternate conditions of 1h immersion in 3%NaCl solution and 5h drying at 60% RH and 25$^{\circ}C$. The result of corrosion rate of Mg thin films deposited at various Ar gas pressures and substrate bias voltage under wet-dry cyclic exposure in chloride-containing solutions was showed the following conclusions. At the region I during the onset of the wet cycle, corrosion rate showed relatively low value. The increase in the Corrosion rate of region II is due to the increase in the chloride concentration. Corrosion rate of region III during the onset of the cycle zero and salt crystals remain on the metal surface.$^{2)}$

  • PDF

The Corrosion Behavior Study by AC Impedance Method for the Aging Heat Treated Nimonic 80A Superalloy (교류임피던스법에 의한 Nimonic 80A 초내열합금 시효열처리재의 부식거동 고찰)

  • 백신영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.761-769
    • /
    • 1999
  • In this paper the effect of aging heat treatment to the Corrosion behavior for the Nimonic 80A superalloy was studied by AC Impedance methods. Tested solution was 3.5% with tempera-ture $25^{\circ}C$ Electro-chemical corrosion test were carried out for the Nimonic 80A super-alloy which solution heat treated at $1080^{\circ}C$ for 8 hours followed by aging heat treated at $650^{\circ}C,\;700^{\circ}C,\;750^{\circ}C\;800^{\circ}C$ and $850^{\circ}C$ with 16hours under vacuum environment. The obtained results were as follows; 1. Base metal and solution-treated materials were exhibited similar corrosion tendency as Ran-dle equivalent cell. The value of passive film resistance was 579 ohms for the base metal and 124,770 ohms for the solutionized metal such a difference was arose by the ${{\gamma}_^'}$ precipitate on the metal surface during heat treatment. 2. The measure value of $R_p$ for heat-treated at $650^{\circ}C,\;700^{\circ}C,\;800^{\circ}C$and $850^{\circ}C$ were 97,943, 93, 111, 26,961, 15,798 and 11,780ohm respectively. Which indicated that the passive film resistance Rp was reduced as aging temperature increased due to the growth of grain size and sensitization at the grain boundary. 3. The similar tendency was exhibited for corrosion behavior of the electro-chemical corrosion polarization method and AC impedance method and confirmed that AC impedance method was useful tool for corrosion research.

  • PDF