• Title/Summary/Keyword: 전기 자극기

Search Result 132, Processing Time 0.024 seconds

Analysis of an External Stimulator's Impact on the Heart (체외 전기자극기가 심장에 미치는 영향의 분석 및 평가)

  • Kim, Mun-Soo;Choe, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1213-1217
    • /
    • 2011
  • Electric stimulators are used for various treatments, such as for pain relief and to improve rehabilitation in and out of the hospital. However, if the stimulation pulse affects the patient's heart, it can cause critical cardiac disorders such as arrhythmia or ventricular fibrillation. As a result, it must be ensured that the transmission length of the stimulation pulse does not exceed the proper range in the design of an electric stimulator. Furthermore, every anticipated risk factor must be monitored in in-vitro and in-vivo experiments. A new stimulator was designed to supply continuous 0.001 J stimulation pulses at a rate of 60 pulses per second. To evaluate the safety of the new electric stimulator and to measure its energy transfer and pulse transmission length, we built a conduction model that was filled with saline and measured the electric field at various positions in response to real stimulations. In an animal experiment with two pigs, heart disorders were induced by applying electric stimulation to tissues near the heart. These heart disorders were different from the result obtained with 9 V DC stimulation.

Development of a Transcutaneous FES System and Its Application to Paraplegic Walking (표면 전극용 기능적 전기자극 시스템의 개발 및 하반신 마비환자의 보행)

  • Song Tongjin;Yi Jeong Han;Khang Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.523-531
    • /
    • 2003
  • We developed a PC-based 8-channel electrical stimulation system for transcutaneous functional electrical stimulation (FES), and applied it to FES exercise and paraplegic walking. The PC program consists of four parts: a database, a stimulation pattern generator, a stimulus parameter converter, and an exercise program. The stimulation pattern can be arbitrarily generated and edited by using the mouse on the PC screen, and the resulting stimulus parameters arc extracted from the recruitment curves, and transmitted to the 8-channel stimulator through the serial port. The stimulator has nine microprocessors: one master and eight slaves, Each channel is controlled by the slave microprocessor, and is operated independently. Clinical application of the system to a paraplegic patient showed significant increase in the knee extensor torque, the fatigue resistance, and the leg circumference, The patient can now walk about 50 meters for more than 2 minutes.

Design and Implementation of Transcutaneous Electrical Nerve Stimulation System for the Integration with Mobile Phone (휴대폰 내장을 위한 경피신경 자극치료기의 설계 및 구현)

  • Woo Sang-Hyo;Yoon Ki-Won;Lee Jyung-Hyun;Park Hee-Joon;Won Chul-Ho;Cho Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.3
    • /
    • pp.360-368
    • /
    • 2006
  • Recently, performance of the mobile phone has increased dramatically. Due to this, it is possible to integrate various biotechnology. There are many ventures to integrate biotechnology with mobile phone, because of increasement interest of peoples well-being. The transcutaneous electrical nerve stimulation can Improve the circulation of blood and suppress a pain. To integrate the transcutaneous electrical nerve stimulation with mobile phone, it is necessity to make small, low power, and safe module. In this paper, the transcutaneous electrical nerve stimulation module is designed and implemented by small boost convertor. The value of tank capacitor, which is the total stimulus energy to human, can be chosen to insure safe condition. The confirm the of operation of designed module, a small micro-controller is used to make system and test the module. The implemented system is small and consumes a low enough power to be integrated with mobile phone.

  • PDF

Human Stimulation Thereshold of Interferential Current Type Low Frequency Stimulator for Electric Shock Experience Education (전기 감전 체험 교육을 위한 간섭 전류형 저주파 자극기의 인체 자극 임계값)

  • Jeon, Jeong-Chay;Kim, Jae-Hyun;Yoo, Jae-Geun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.808-811
    • /
    • 2012
  • 매년 높은 비율의 전기안전사고가 발생하지만 예방교육은 단순한 영상홍보나 단순 텍스트를 이용한 교육 수준에서 주입식으로 이루어지고 있다. 항공, 군사, 전력산업 등 다양한 분야에서는 가상현실을 이용한 체험형 교육 시스템이 개발되어 운영되지만 전기안전 예방교육은 감전사고와 같은 특수한 상황의 체험과 사고를 유발시킬 수 있다는 측면에서 체험형 교육시스템이 개발 및 적용이 어렵다. 따라서 본 연구에서는 전기감전 체험교육 시스템에 저주파 자극 장치를 사용할 수 있도록 저주파 간섭형 자극기를 이용한 인체 자극의 임계값 산출시험을 실시하고 대표적으로 성별, 연령별(아동 및 성인 구분)로 구분하여 적절한 자극값을 산출하였다. 본 연구의 결과는 향후 전기안전사고 예방을 위한 체험형 예방 교육 시스템에 활용이 가능할 것이다.

  • PDF

The Study on Electromagnetic Stimulator for Healing of Ununited Fracture (비접합성 골절의 치료를 위한 전지가지 자극기에 관한 연구)

  • Gun-Ki Lee;Han
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.143-148
    • /
    • 1984
  • 비접합성 골절의 치료를 위한 전기적인 방법으로는 관혈적이 방법, 부분적으로 관혈적인 방법, 비관혈적인 방법 들이 있는데, 비관혈적인 방식은 다른 방법들과는 달리 수술 등 외과적 처기 등이 필요하지 않을뿐더러 환자에게도 가장 안전한 방식이다. 본 논문에서는 유도 결합 현상을 이용한 반관혈적인 전기 자기 자극기를 설계, 제작하였으며, 임상 실험 겨과 좋은 결과를 보이고 있다.

  • PDF

Auditory Sensation by the Inserted "Electronic Cochlea" in the Cases of the Experim entally Destroyed Receptor Organ of Corti of the Cat (와우 수용기 모세포를 파괴한 가묘의 "전기와우" 삽입에 의한 "청각감")

  • 장인원;김성남;양한모;정규화;최윤호;정종진;조용범;국태진;이정헌
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.4.3-4
    • /
    • 1979
  • In the cases of the experimentally destroyed receptor organ of the Corti of the cats, "electric cochlea" were inserted near the auditory neuron through the Scala tympani as an input of the inner device, and outer device is placed near the receiver of the audiometer. During exposing noise through the outer device, kymographic record were obtained as following: 1) Correlation between increasing intensity and amplitude showed parallel responses 2) The auricular reflex by repeated stimulation of the sound showed considerable increase at first, and decrease respectively. 3) In this experimental animals, absolutely non-responsed period, relatively non-responsed period and responsed period were observed. 4) Above mentioned reflex indicate that "Auditory sensation" can be induced by inserted "Electric cochlea" in the cases of the experimentally destroyed receptor organ of Corti of the cats.

  • PDF

Effect of Reserpine on Pancreatic Exocrine Secretion Induced by Mesencephalic Reticular Stimulation in Rats (흰쥐에서 Reserpine이 중뇌망상체의 자극으로 유발된 췌장의 외분비 기능에 미치는 영향)

  • Park, Hyoung-Jin;Lee, Yun-Lyul
    • The Korean Journal of Physiology
    • /
    • v.22 no.1
    • /
    • pp.101-109
    • /
    • 1988
  • 최근에 마취한 흰쥐에서 중뇌망상체를 전기적으로 자극하면 췌장의 외분비 기능이 증가하며 이러한 결과는 망상체의 자극으로 인하여 교감신경계의 활성도가 상승하기 때문이라는 보고가 있다. 한편 교감신경계의 활성도가 상승할 경우 교감신경계의 전달 물질인 catecholamine이 교감신경 종말 뿐만 아니라 부신수질에서도 유리된다고 알려져 있다. 그러므로 본 연구에서는 중뇌망상체의 자극으로 인하여 췌장의 외분비 기능이 증가함에 있어 교감신경계가 중요한 역할을 담당하는지를 확인하고, 이때 부신수질이 관여하는가를 알아보고자 하였다. 마취한 흰쥐에게 atropine (1mg/kg) 또는 reserpine (5mg/kg)을 투여하거나 또는 부신을 적출한 다음 중뇌망상체를 전기 자극하면서 췌장액을 채취하였다. 사용한 전기자극의 매개변수는 1.3V, 40Hz, 2msec이었다. atropine과 reserpine을 투여하면 마취한 흰쥐의 자발적 췌장액 분비량과 단백질 분비량은 모두 유의하게 감소하였으나 부신을 제거하면 췌장액 분비량에는 이렇다할 변동이 없는 반면에 단백질 분비량은 유의하게 감소하였다. 중뇌망상체를 전기자극하면 췌장액 분비량과 단백질 분비량 모두가 유의하게 증가하였다. 이러한 망상체의 자극효과는 atropine 전처치에 의하여 이렇다할 영향을 받지 않았으나 reserpine 전처치에 의하여 소실되었다. 그러나 부신을 적출하면 망상체 자극에 의한 췌장액 분비량의 증가는 유지되는 반면에 단백질 분비량의 증가는 소실되었다. 한편 미주신경을 절단한 흰쥐에서 중뇌망상체를 자극하는 동안에 경동맥의 수축기 및 이완기 혈압이 상승하였는데 이러한 망상체의 자극효과도 reserpine의 투여에 의하여 유의하게 감소되었다. 본 실험의 결과를 종합하여 보면 마취한 흰쥐에서 중뇌망상체의 자극은 교감신경계를 활성화시켜 췌장액 분비량과 단백질 분비량에 촉진적인 영향을 미치며, 이때 활성화된 교감신경계는 부분적으로 부신을 경유하게 췌장의 단백질 분비에 촉진적인 영향을 미치는 것으로 생각된다.

  • PDF

Development of EMG-Triggered FES System and Optimal Electrode Location for Chronic Hemiplegic Patients (편마비 환자를 위한 근전도 유발 기능적 전기자극기의 개발과 이상적인 전극부착 위치)

  • 박병림;안상호;정호춘;진달복;김성곤;이상세;김영기
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.151-156
    • /
    • 2004
  • The purpose of this study was to develop EMG triggered FES system for restoration of upper extremity function in chronic hemiplegic patients and to identify the optimal location of electrode application for the EMG triggered FES system which produces effective muscle contraction and detects EMG activity for extension in the wrist and finger joints. The stimulus system was composed of EMG measuring component, constant current component and the program for muscle contraction by EMG triggered FES and passive FES. Parameter of electrical stimulation was 35 ㎐ in frequency, 150 ${\mu}\textrm{s}$ in pulse width and symmetric bi-phasic wave. In 15 hemiplegic patients, EMG triggered FES was applied to the proximal half of forearm which was divided into 12 areas. The most sensitive area for measuring EMG activities during extension of the wrist and fingers was area 4, 5 and the optimal location of electrical stimulation for producing extension of the wrist and fingers was area 4, 5, 7, 8. These results suggest that the area 4 and 5 was considered as the most optimal location of electrode application for measuring EMG activities as well as producing extension of the wrist and fingers by EMG triggered FES system.

Development of an Auto Stimulus Breaker During the Electric Pulp Testing using Human Responses (전기 치수 검사 시 인체 반응을 이용한 자극 제어기의 개발)

  • 남기창;안선희;이승종;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.6
    • /
    • pp.43-49
    • /
    • 2004
  • Electric pulp test is a method to examine the vitality of dental pulp using physical and chemical stimulation. During the pulp test, the current stimulates intradental nerve, and it makes patients painful. In this paper, we measured each activating response EMG in anterior belly of digastric muscle, voice, and finger movement during the pulp test by increasing stimulus intensity gradually. We also measured excessive stimulus time from the activating responses (EMG, voice, and finger movement) to the end of the stimulation. We measured and analyzed excessive stimulus time for each stimulus detecting method. As a result, we developed automatic stimulus breaker using the human responses to stimulus during electric pulp test. We reduced the excessive stimulus time by disconnecting the pulp tester stimulus output rapidly in 10 ms after activating human response.

Measurement of Vestibular Ocular Reflex in Normal Subjects Using Galvanic Stimulator and Videooculograph (전기자극과 VOG(Videooculograph)를 이용한 정상인의 전정 안반사 측정)

  • 김수찬;정운교;남기창;이원상;김영하;김덕원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.487-496
    • /
    • 2001
  • In this study, a galvanic stimulator providing bipolar mode controlled by a PIC(peripheral interface controller) was constructed to evaluate vestibular function The maximum load and maximum current intensity of the constant current source were 3$k\Omega$ and 5mA. respectively. and it could Produce DC, sine wavers. or Pulse waves. Eve movements of 20 normal subjects by galvanic stimulation were analyzed using a commercial videooculogragh. During stimulating with DC for 30 sec. we recorded the response of eye movement with current intensity of 0.75. 1 2, and 3 mA. Nystagmus occurred to all the subjects when the galvanic stimulus intensity was larger than 2 mA. Average SPV(slow Phase eye movement velocity) and the number of nystagmus increased from 7.1 to 4.8 deg/sec and from 17 to 48, respectively, when the stimulus current increased from 0.75 to 3 mA. All the fast eye movement of the nystagmus were the direction of the negative electrode. The asymmetry which means the difference between right- and left-eye movements decreased when the stimulus intensity increased. It is expected that this study would be useful in evaluating vestibular function and in studying basic Physiology mechanism of vestibular ocular reflex by galvanic stimulus .

  • PDF