• Title/Summary/Keyword: 전기 아크

Search Result 522, Processing Time 0.029 seconds

A Study on Auxiliary Control Safety Apparatus for RCD Trip on Electric Arc and Spark Disasters - Using by Power Semiconductor Switching Device - (아크 및 스파크 재해에 대한 누전차단기 트립을 위한 보조제어 전기안전장치에 관한 연구 - 전력용 반도체 스위칭 소자 적용 및 응용 -)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.71-76
    • /
    • 2006
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

국내외 정보

  • Korea Electrical Manufacturers Association
    • NEWSLETTER 전기공업
    • /
    • no.96-2 s.147
    • /
    • pp.22-49
    • /
    • 1996
  • PDF

전기응용

  • 대한전기학회
    • 전기의세계
    • /
    • v.27 no.2
    • /
    • pp.76-81
    • /
    • 1978
  • (차례) I.전열 1.유도가열 및 유전가열 2.아아크 가열 및 저항가열 II.조명 1.조명의 기초와 측정 2.조명방식과 실제 3.광원 4.조명기구

  • PDF

A Study on Analysis of Arc Current Waveforms for Detection of Prognostics of Electrical Fires (전기화재 징후 감지를 위한 아크전류 파형분석에 관한 연구)

  • Hwang, Jin-Kwon
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2009
  • Several electrical loads such as inrush current, normal operation arcing and non-sinusoidal loads have normal current waveforms similar to arc waveforms. To detect arcs in such loads, therefore, it is necessary to analyze difference between current waveforms with or without arcs. In this paper, using apparatuses of arc generation in UL 1699, arcs are generated in these loads and, then, arc current waveforms are investigated in both the time and the frequency domains to find arc characteristics. This investigation shows that arc current signals have shoulders at some zero current points in the time domain and increment of spectrum magnitude in all over frequency domain. It also shows that the arc characteristics at normal operation arcing and non-sinusoidal loads are detected more easily in the frequency domain than in the time domain. This investigated arc characteristics are expected to be utilized as the basis of development of arc-fault circuit interrupters.

Study on the Arc Detection of Distribution Panel using IR Camera (적외선 카메라를 이용한 폐쇄분전반 아크 검출에 관한 연구)

  • Oh, Y.C.;Kim, T.Y.;Lee, Y.S.;Oh, H.S.;Hyun, D.C.;Park, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1537-1538
    • /
    • 2015
  • 전력사용량이 산업발전과 더불어 기하급수적으로 증가하고 있으며, 한정된 공간내에서 대용량의 전력설비를 설치하기 위해 폐쇄형 배전반이 운영되고 있다. 한국전기안전공사에서 발표한 통계자료에 의하면, 고압이상 전기설비 검사결과 절연내력이 불합격인 경우가 다수 발생하고 있으며, 이는 아크 플래시 사고의 원인이다. 특히 수배전반의 경우 부하설비 또는 외부의 영향을 확인할 수 있는 장치 및 보호설비가 설치되어 있으나 자체 안전장치가 마련되어 있지 않아 자체사고를 신속히 검출하고 판단할 수 있는 기술이 필요하다. 본 논문에서는 해상도가 낮은 저가의 열화상 센서에 고속 DSP를 사용하여 영상처리 기법인 이차원 보간 법으로 해상도를 올려서 사용하는 기술을 이용하여 아크에 의해 발생되는 열특성을 검출하고 검출된 데이터를 전송하여 전기화재사고를 미연에 방지할 수 있는 장치 개발을 위한 기초 특성조사를 실시하였다.

  • PDF

Experimental Study on the Corrosion Behavior of Al Coatings Applied by Plasma Thermal Arc Spray under Simulated Environmental Conditions (모사 부식 환경에서 플라즈마 아크용사에 의한 Al 코팅의 부식특성에 관한 실험적 연구)

  • Jeong, Hwa-Rang
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.5
    • /
    • pp.559-570
    • /
    • 2023
  • The corrosion of structural steel used in the construction industry is increasing due to the industrialization where many aggressive ions released in the atmosphere. Therefore, in the present study Al coating was deposited by arc and plasma arc thermal spray process and compared their effectiveness in simulated weathering condition i.e. Society of Automotive Engineers(SAE) J2334 solution which mostly contain Cl- and CO32- ions. Different analytical techniques have been used to characterize the coating and draw the corrosion mechanism. The Al coating deposited by plasma arc thermal spray process exhibited uniform, dense and layer by layer deposition resulting higher bond adhesion values. The open circuit potential(OCP) of Al coating deposited this process is exhibited more electropositive values than arc thermal spray process in SAE J2334 solution with immersion periods. The total impedance of plasma arc thermal spray process exhibited higher than arc thermal spray process. The corrosion rate of the plasma arc thermal sprayed Al coating is reduced by 20% compared to arc thermal spray process after 23 days of immersion in SAE J2334 solution.

Tests of AFCI Using Carbonized Path Arc Test of UL 1699 (UL 1699의 탄화경로 시험방법에 의한 AFCI 성능시험)

  • Kim, Chong-Min;Bang, Sun-Bae;Kim, Oh-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2172_2173
    • /
    • 2009
  • UL 1699 규정에서 제시된 다양한 시험방법을 분류하고, 시험방법 중의 하나인 carbonized path arc clearing time test의 시험설비를 구축하였으며, 시험방법 및 절차에 대해 소개하였다. 또한 국내에서 개발되어진 cord 타입 AFCI를 대상으로 시험을 실시하였으며 시험결과 국내에서 개발되어진 cord 타입의 AFCI는 부하전류 3[A]에서도 아크고장을 검출하며 모든 시험전류에서 적합하게 아크를 차단하는 것을 알 수 있었다.

  • PDF

Electrochemical characteristics of electric arc sprayed steel using sacrificial anodic wires (희생양극 선재로 아크 용사코팅된 강재의 전기화학적 특성 평가)

  • Park, Il-Cho;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.318-318
    • /
    • 2015
  • 해양환경 하에서 SS400강의 부식 방지를 위하여 Al과 Al-Mg합금 선재를 이용한 아크용사코팅을 실시하였다. 그리고 다양한 전기화학적 실험으로 내식성을 평가하였으며, 실험 후에는 주사전자현미경(SEM)과 3D 현미경을 이용하여 손상된 표면의 형상 및 손상깊이를 상호 비교하였다.

  • PDF

Tests of the arc-resistant characteristics of nozzle and arcing contact for EHV class GCB (초고압급 가스차단기용 노즐 및 아크접점의 내아크 특성시험)

  • Song, K.D.;Chong, J.K.;Park, K.Y.;Kweon, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.89-93
    • /
    • 1997
  • Various types of nozzles and arcing contacts for EHV class GCB have been made to investigate the arc-resistant characteristics of them during short-circuit tests. The tested results are presented and analyzed to give useful information for GCB nozzle and contact manufacturers.

  • PDF

Prediction to Dry-Band Arcing in Live Line Installation (OPGW활선 공사시 건조대 아크 예측)

  • Kim J. N.;Kim S. W.;Baekm J. H.;Jeon S. I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.433-435
    • /
    • 2004
  • 본 논문에서는 기존의 가공지선(GW, Ground Wire)을 OPGW(Optical Ground Wire)로 교체공사를 할 경우 나타나는 절연로프에서의 건조대 아크현상을 수치적인 모델링를 통하여 해석할 수 있는 프로그램을 제작하고 현장조건을 입력하여 문제점을 판단하고 해결할 수 있는 방안을 제시하고자 한다.

  • PDF