• Title/Summary/Keyword: 전기화재

Search Result 813, Processing Time 0.026 seconds

A Study on the Inflammable Gas Explosion Triggered by the Electric Discharge Static Eliminator on Voltage Application Type (전압인가식 제전기의 방전에 의한 가연성가스의 폭발에 관한 연구)

  • Lee Chun Ha;Ok Kyoung Jea;Kim Jum-Ho;Kwon Byung-Duck;Cha Ha-Na;Yun Kea Won
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.22-26
    • /
    • 2004
  • The static eliminator is used for prevention of disasters by static discharge, improvement of production efficiency, protection of a sensitive electronic element on the discharge of static, and it is handled for elimination of static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the explosion appearance by discharge phenomena on the voltage input type eliminator's ion generation bar of inflammable gas through an experimental tests. It was used Hydrogen, Ethylene, Propane, Methane gas with the inflammable gas and it was studied on the ignition phenomena by the length of ion-generation static bar, the number of ion-generation electrode and the variation of input voltage to the ion-generation electrode. As a result of this study it was confirmed that the shorter of the bar's length, the greater of explosion danger. And it is considered that there will not ignite at general using inflammable gas, in case of more than 900 mm bar and one electrode.

A Study on the Analysis of Heat and Metallurgical Structure of Connection Parts for Residual Current Protective Devices (저압용 누전차단기 접속부의 발열 및 금속 조직 분석에 관한 연구)

  • Choi Chung-Seog;Shong Kil-Mok;Kim Dong-Ook;Kim Dong-Woo;Kim Young-Seok
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.57-63
    • /
    • 2004
  • We investigated heat properties of connection terminal in residual current protective devices(RCD) according to contact pressure for low voltage appliance. And we analyzed voltage and current waveform and oxide propagation when the poor-contact happened between terminal and wire. When contact pressure between terminal and connection wire was not applied, the heat was generated and an oxide was formed on the surface of the wire. The temperature of the insulation surrounding terminal was ascended sharply by poor-contact, micro-sparks and continuous arc sound happened in interior terminal. When the poor-contact by vibration occurred inner conductor of terminal and wire, an oxide was propagated on contact surface and the temperature was increased at 869℃. Thus, we found that the risk of electrical disaster is high in terminal and connection wire parts.

A Study on the Improved Ignition Limit with Resistor for Propan-air Mixture Gas (저항을 이용한 프로판-공기 혼합가스의 점화한계 개선에 관한 연구)

  • 이춘하;오종용;옥경재;지승욱;이광식;심광렬
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 2004
  • This paper describes the minimum ignition limits for propane-air 5.25 Vol.% mixture gases in low voltage inductive circiuts. The improved effects on the ignition limit are studied by parallel safety components(resistors) for propane-air 5.25 Vol.% mixture gas in low voltage inductive circuits. The experimental devices used in this test are the IEC type spark ignition test apparatus. The minimum ignition limits are controlled by the values of current in inductive circuit. Energy supplied from electric source is first accumulated at the inductance, it's extra energy is working as ignition source of the explosive gas. The improved effects on the ignition limit are respectively obtained as the maximum rising rate of 330% by composing parallel circuits between inductance and resistor as compared with disconnecting inductance with the safety components. The more values of inductance increase the higher improved effects of ignition limit rise. The less values of resistor the higher improved effects of ignition limit rise. It is considered that the result can be used for not only data for researches and development of intrinsically safe explosion-proof machines which are applied equipment and detectors used in dangerous areas but also for datum for its equipment tests.

A Study on the Ignition Temperature and Ignition Induction Time According to Storage Amount of Wood Pellets (우드펠릿의 저장량에 따른 발화온도 및 발화유도시간에 관한 연구)

  • Kim, Hyeong-Seok;Choi, Yu-Jung;Kim, Jung-Hun;Jeong, Phil-Hoon;Choi, Jae-Woo
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.7-14
    • /
    • 2019
  • While wood pellets are often used as a fuel in thermoelectric power plants and firewood boilers, there is a risk of ignition temperature when strong wood pellets, which have a high calorific value, for prolonged periods of time. In this research study, the minimum auto ignition temperature and the ignition limitation temperature according to the change in flow rate depending on the size of the test vessel were calculated, and based on these temperatures, the apparent activation energy was calculated to predict the combustive properties of the material. The apparent activation energy was calculated to be 190.224 kJ/mol. The thicker the sample is storage in the vessel, the longer the ignition induction time was due to the increased difficulty in heat being transferred from the surface of the vessel to the middle section area of the vessel. For vessel of the same size, the higher the flow rate, the lower the auto ignition temperature was. It was also confirmed that increases in the size of the test vessel lowered the auto ignition temperature and increased the ignition induction time.

A Study on Safety Impact Assessment of a Multiple Hydrogen Refueling Station (다차종 동시 충전을 위한 수소 스테이션의 안전 영향 평가 연구)

  • Boo-Seung Kim;Kyu-Jin Han;Seung-Taek Hong;Youngbo Choi
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.85-99
    • /
    • 2024
  • As the proliferation of hydrogen electric vehicles accelerates, there is observed diversification in hydrogen refueling station models. This diversification raises safety concerns for different types of stations. This study conducted a quantitative risk assessment of a multi-vehicle hydrogen station, capable of simultaneously refueling cars, buses, and trucks. Utilizing Gexcon's Effects&Riskcurves Software, scenarios of fire and explosion due to hydrogen leaks were assessed. The study calculated the impact distances from radiative heat and explosion overpressure, and measured risks to nearby buildings and populations. The largest impact distance was from fires and explosions at dispensers and high-pressure storage units. High-pressure storage contributes most significantly to personal and societal risk. The study suggests that conservative safety distances and proper protective measures for these facilities can minimize human and material damage in the event of a hydrogen leak.

The Testing Methods of the Fire and the Electric Shock on the Electric Pad Using the House (가정용 전기매트에 대한 화재 및 감전 시험법에 관한 연구)

  • Jang, In-Hyeok;Lee, Chang-Hoon;Lee, Young-Joo;Lim, Houng-Woo
    • Journal of Applied Reliability
    • /
    • v.14 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • In this paper, the evaluating test methods of the fire and the electric shock on the Electric pad using the house is proposed. We analyzed electric pad using magnetic shielded type hot wire because electric pad using the magnetic shielded type hot wire generally be used in the home. We analyzed FMEA in order to analyze the mechanism of the fire and the electric shock of the electric pad and designed testing methods (Durability tests on the environment, Mechanical durability tests, Electrical durability tests) obtained through the two-step QFD and tested. We verified the evaluating test methods of the fire and the electric shock on the Electric pad using the house through the analysis of the test results.

상수도 원격자동검침시스템에 관한 연구

  • Seo, Chang-Gap;Park, Yeong-Jae;Jeong, Gwang-U
    • 한국경영정보학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.1036-1042
    • /
    • 2007
  • 현재 우리나라 상수도 시스템의 경우 대부분 각 가정집에 설치된 계량기의 측정값을 검침원이 육안으로 확인, 수기 기입 방법으로 수도 검침이 이루어지고 있다. 이러한 방법은 사생활 침해 및 범죄로 이어질 가능성이 있다. 본 논문에서는 상수도의 검침데이터를 무선주파수 및 코드분할다중접속방식을 사용하여 송수신 가능한 네트워크 망을 구축, 수신된 데이터 값을 활용하여 각 상수도 수용가의 사용량을 자동으로 검침하여 청구 내역서까지 작성해 주는 상수도 자동검침시스템을 소개한다. 상수도 자동검침시스템은 검침을 디지털화하고 이를 무선송신 가능한 검침기와 검침기의 검침데이터 값을 송수신 할 수 있는 중계기 및 집중기, 그리고 CDMA 망을 통한 검침데이터를 수신할 수 있는 애플리케이션 서버 등을 구축하여 지역 내 원격 검침 네트워크 망을 구축하는 것을 포함하고 있다. 본 연구의 시스템은 화재, 가스, 전기 등의 검침데이터를 통합으로 수집하여 데이터를 관리하는 통합 시스템으로 확대가 용이하며 이러한 상수도 자동검침시스템은 누수 및 독거노인 등의 생활보호대상자의 안전을 확인하는 기초 정보로도 활용할 수 있다.

  • PDF

A Study on the Verification Scheme for Electrical Circuit Analysis of Fire Hazard Analysis in Nuclear Power Plant (원전 화재위험도분석에서 전기회로분석 검증방안에 관한 연구)

  • Yim, Hyuntae;Oh, Seungjun;Kim, Weekyong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.114-122
    • /
    • 2015
  • In a fire hazard analysis (FHA) for nuclear power plant, various electrical circuit analyses are performed in the parts of fire loading analysis, fire modeling analysis, separation criteria analysis, associated circuit analysis, and multiple spurious operation analysis. Thus, electrical circuit analyses are very important areas so that reliability of the analysis results should be assured. This study is to establish essential electrical elements for each analysis for verification of the reliability of the electrical circuit analyses in the fire hazard analysis for nuclear power plants. Applying the results derived by the study to domestic nuclear power plants, it is expected to determine the adequacy of the fire hazard analysis report and contribute to the reliability of the fire hazard analysis of those plants.

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load (전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구)

  • Lee, Sang-Ho;Oh, Hong-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF