• Title/Summary/Keyword: 전기침투

Search Result 250, Processing Time 0.032 seconds

Effects of High Voltage Pulsed Electric Fields on the Extraction of Carotenoid from Phaffia rhodozyma (Phaffia rhodozyma로부터 Carotenoid 추출에 미치는 고전압 펄스 전기장의 영향)

  • Kim, Nam-Hoon;Shin, Jung-Kue;Cho, Hyung-Yong;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.720-726
    • /
    • 1999
  • High voltage pulsed electric fields (PEF) technology is a non-thermal technique which is applicable to extract useful components froms biological materials. This research suggested the possibility for extracting carotenoid pigments from Phaffia rhodozyma by PEF treatments. The yeast cell suspensions were treated with high voltage pulses in a recycled PEF treatment chamber which consists a pair of thin plates of stainless steel adhering to a small chamber with approximately $1{\sim}4\;mm$ gap. A 2.5 log reduction in survivability and more than 98% of electropermeabilization of the yeast cells could be achieved by PEF treatment for $300\;{\mu}s$ with an electric field of 30 kV/cm and pulse duration of $1\;{\mu}s$. When the yeast cell suspended in 0.01% NaCl solution were treated with PEF under various conditions, carotenoid pigments were not extracted. However, the PEF treatment of the yeast cell suspensions in 0.01% $CaCl_2$ solution, have positive effects on the extraction of carotenoid pigments ($27.3\;{\mu}g/g$ of dried yeast).

  • PDF

Geoelectrical laboratory and field studies of groundwater occurrence in a landslide area: a case study from Japan (전기비저항탐사에 의한 산사태 지역의 지하수조사)

  • Park Sam-Gyu;Asano Shiho;Matsuura Sumio;Okamoto Takashi;Kim Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.86-91
    • /
    • 2005
  • We present the results of electrical resistivity surveys carried out to estimate the seasonal variation of the water table level in a large-scale landslide area of Tertiary geology in Japan. One long profile, trending NE-SW, was established perpendicular to the main regional geology of the region. Three boreholes are located very close to the profile. The profile was surveyed twice, once before snowfall and once after snow had melted. The relationship between resistivity and water saturation of pyroclastic materials was clarified through laboratory tests. We did this in order to estimate the water content of the pyroclastic layer from the observed resistivity distribution in the landslide area. The resistivity of the saturated pyroclastic deposit calculated using an empirical formula was found to be $570{\Omega}.m$. Based on this computed resistivity, the groundwater level was deduced by assuming that the pyroclastic deposits were fully saturated beneath the water table. We show that the estimated water table before snowfall is lower than that inferred after snow has melted, by about 1.1 to 4.7 m. This suggests that the water table in the upper part of the pyroclastic layer in the landslide area fluctuates greatly, compared to the lower part. This seasonal groundwater fluctuation is possibly caused by the infiltration of water into the subsurface after snowmelt.

Evaluation of Chloride Extraction under Electrochemical Chloride Extraction (전기화학적 염화물 추출법에 따른 염소이온 제거 성능 평가)

  • Jiseok, Kim;Ki-Yong, Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.553-557
    • /
    • 2022
  • The present study evaluate the chloride extracion under electrochemical chloride extraction method. Chloride was penetrated into the concrete from external reservoir using a 4M NaCl solution, and an electrochemical chloride extraction method was applied after the curing period of 1 year. The current density was constantly kept 1000 mA/m2 for coulostatic application with the variation in potential difference. The duration of the ECE treatment was 2, 4, 8 weeks, respectively. The residual chloride concentration at all depths decreased, and the chloride concentration decreased as the application period increased. After the application period of 8 weeks, 62.9 to 77.6 % of chloride extracted in the total chloride profile, and 77.7 to 99.5 % of chloride extracted in the free chloride profile. In particular, the concentration of free chloride at a depth of 7 mm or more from the concrete surface was 0.01 % or less by cement. In addition, it was confirmed that the bound chloride could be extracted by the electrochemical chloride extraction.

Protection for sea-water intrusion by geophysical prospecting & GIS (해수침투 방지를 위한 물리검층과 GIS 활용방안)

  • Han Kyu-Eon;Yi Sang-Sun;Jeong Cha-Youn
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.54-69
    • /
    • 2000
  • There are groundwater trouble by high-salinity yield inducing sea-water intrusion in Cheju Island. It is used groundwater-GIS(Well-lnfo) in the maintenance and management of groundwater in Cheju Island to grasp groundwater trouble area and cause of high-salinity yield. For 16 wells certain to yield high-salinity, we logged specific electrical conductivity(EC) and tried to get hold of freshwater and saltwater relationship. As result of distribution of $Cl^-$ by depth, it is showed up groundwater trouble by high-salinity yield in the east coastal area and the partly north coastal area. The reason of high-salinity groundwater yield are low-groundwater level by the structure of geology and low-hydraulic gradient etc. There is necessity for management to development and use of groundwater in the high-salinity area, special management area.

  • PDF

Study on analysis of coating layer by FE-SEM image (FE-SEM을 이용한 도공층 공극 구조 분석 연구)

  • Kim, Jin-U;Lee, Hak-Rae;Yun, Hye-Jeong
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2010.04a
    • /
    • pp.67-67
    • /
    • 2010
  • 이미지를 이용한 도공층 구조 분석은 도공층의 실제 Morphology를 분석하여 평가하는 방법으로서 최근 세밀한 도공층 구조 분석을 위해 이 방법에 대한 많은 연구가 진행되고 있다. 특히 이러한 방법은 수은압입법(Mercury intrusion)이나 질소흡착법 (Nitrogen adsorption by BJH theory) 등과 같은 기존의 공극 특성 평가 방법과 달리 pore aspect ratio 및 orientation 등과 같은 공극 dimension을 평가할 수 있는 장점이 있다. 이러한 공극 dimension은 size distribution 및 porosity와 더불어 인쇄, 라미네이션 접착 등과 같은 Liquid interfacial 및 침투 측면에서 중요한 요소이기 때문에 이를 평가하기 위한 적합한 방법으로 인식되고 있다. 또, 원지 부분과 도공층 간의 경계를 명확하게 보여주고 Surface와 Cross-section 영역을 구분하여 평가 할 수 있어 더 명확한 평가를 가능하게 한다. 본 연구에서는 이미지 분석을 통해 도공액 구성 조건에 따른 도공층의 공극 구조 특성을 평가 하였고 일부 요소에 대해서는 수은 압입법과 비교 평가하여 이미지 분석법과의 상관성에 대해 고찰 하였다. 본 연구에서 사용된 FE (Field Emission)-SEM은 일반 SEM과 달리 전압에 의한 높은 전기장의 형성을 통해 저 가속 전압으로 이미지를 구현하는 장비로서 본 연구에서는 FE-SEM을 통해 도공층의 세밀한 Morphology와 공극 구조 이미지를 구현할 수 있었다.

  • PDF

Factors Affecting Shelf-life of Washed Shell Eggs (세척란의 저장성에 영향을 미치는 요인)

  • 전기흥;박영신;유익종
    • Korean Journal of Poultry Science
    • /
    • v.20 no.1
    • /
    • pp.33-41
    • /
    • 1993
  • Among the several factors that affect shelf-life of washed shell eggs, storage temperature and relative humidity were the most important. Besides those factors listed above, temperature of washing water, composition of foreign substances and washing method of eggs were also the factors affecting the shelf-life of the eggs. The effect of sanitizer treatment was significant in extending the shelf-life of eggs compared with washed and unwashed eggs. In case of oil coating treatment, the shell eggs treated showed the better results than that of washed and unwashed eggs because the coating materials prevented the moisture evaporation from the inner shell eggs and kept the contamination of microorganisms from the environment. Consequently, it is considered that reducing egg shell contamination of microorganisms and proper treatment could be the key to extend the shelf-life of shell eggs.

  • PDF

Experimental Study on the Chloride Invasion Resistance Properties of Concrete Containing Mineral Admixtures (혼화재 혼입 콘크리트의 염화물 침투저항성에 관한 실험적 연구)

  • Yoo, Jae-Kang;Kim, Dong-Seuk;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.43-48
    • /
    • 2003
  • This paper investigate that the effect of the concrete containing mineral admixtures(pozzolanic materials such as fly-ash, ground granulated blast-furnace slag, silica fume and meta kaolin) on the resistance properties to chloride ion invasion. The purposed testing procedure was applied to the concrete added mineral admixtures for 3~4 replacement ratios under W/B ratios ranged from 0.40 to 0.55. For the electrical migration test, Tang and Nilsson's method was used to estimate the migration coefficient of chloride ion. As a results, the W/B ratios, kinds of admixture and replacement ratios, water curing periods had a great effect on the migration coefficient of chloride ion, and the optimal replacement ratios of admixture had a limitation for each admixtures. Also, the addition of mineral admixtures by mass(replacement of OPC) enhanced the resistance of the mixture to chloride penetration compared with the plain concrete. The amount of acid soluble chloride ions and water soluble chloride ions were varied with the kinds of mineral admixtures. The compressive strength was shown related to the migration coefficient of chloride ion, the compressive strength increased with the decreasing migration coefficient of chloride ion. Below the 50MPa, the variation of migration coefficient of concrete added mineral admixtures was bigger than plain concrete.

  • PDF

Experimental Study on the Chloride Invasion Resistance Properties of Concrete Containing Mineral Admixtures (혼화재 혼입 콘크리트의 염화물 침투저항성에 관한 실험적 연구)

  • 유재강;김동석;이상수
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.43-48
    • /
    • 2003
  • This paper investigate that the effect of the concrete containing mineral admixtures(pozzaolanic materials such as fly-ash, ground granulated blast-furnace slag, silica fume and meta kaolin) on the resistance properties to chloride ion invasion. The purposed testing procedure was applied to the concrete added mineral admixtures for 3∼4 replacement ratios under W/B ratios ranged from 0.40 to 0.55. For the electrical migration test, Tang and Nilsson's method was used to estimate the migration coefficient of chloride ion. As a results, the W/B ratios, kinds of admixture and replacement ratios, water curing periods had a great effect on the migration coefficient of chloride ion, and the optimal replacement ratios of admixture had a limitation for each admixtures. Also, the addition of mineral admixtures by mass(replacement of OPC) enhanced the resistance of the mixture to chloride penetration compared with the plain concrete. The amount of acid soluble chloride ions and water soluble chloride ions were varied with the kinds of mineral admixtures. The compressive strength was shown related to the migration coefficient of chloride ion, the compressive strength increased with the decreasing migration coefficient of chloride ion. Below the 50MPa, the variation of migration coefficient of concrete added mineral admixtures was bigger than plain concrete.

  • PDF

The Evaluation of Reliability of Chloride Ion Penetration the Test of Concrete due to the Population Mean in One Group (단일 집단의 모평균 검정에 의한 콘크리트의 염소이온 투과시험의 신뢰성 평가)

  • Min, Jeong-Wook;Park, Seung-Bum;Lee, Joon;Lee, Byeong-Jai
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.553-556
    • /
    • 2008
  • We have studied about chloride penetration test by electrical conductance to 10 specimens made from same test batch. The coefficient of variation of total passed charge(Colombs) was about 24% in same specimens, and we draw a conclusion this method has a low reliability. Owing to complicated reaction ; heterogeneous material, mixing error and error of testing method, then we must consider the scope of the error which is introduced. Specially when you trying to get one test result against one spcimen, you can commit a big error, therefore we recommend that you use mean value against 3 specimens at least.

  • PDF

Weight Reduction Property of Sea-Islands Type PET Supermicrofiber (해도형 초극세 폴리에스테르 섬유의 용출 특성)

  • Jeong, Cheon-Hee;Min, Mun-Hong
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.59-59
    • /
    • 2011
  • 초극세 섬유는 종래의 섬유와 비교해서 매우 가늘고 큰 표면적을 지니므로 섬유고분자 고유의 성질 이외에 활성이 높은 섬유표면이 가지는 특수한 성질의 기여가 매우 커지게 되므로 흡착특성이나 접착특성 등 특수한 성질의 기여가 매우 커지게 된다. 초극세 섬유를 제조하는 방법은 통상적으로 멜트블로운법, 플래쉬법, 전기방사법 그리고 해도형 복합방사법의 4가지로 분류된다. 그중 해도형 복합방사법은 가장 안정적인 방법으로 PET기준으로 0.01데니어 급까지 상용화가 되어 있다. 해도형 복합섬유의 개발에 있어서 중요한 것 중에 하나가 해성분 폴리머의 용출기술이다. 초극세화를 목적으로 해성분인 변성폴리에스테르를 제거시키기 위해서 실시되는 알칼리(NaOH)에 의한 감량공정은 그 처리조건에 따라서 초극세사로 잔존해야하는 도성분의 정규 폴리에스테르까지 손상시킬 수 있기 때문에 균일한 용출조건의 확립은 매우 중요하다. 그러나 초극세화가 진행될수록 알칼 리가 섬유 내부까지 균일하게 침투하기가 어려우며 감량된 도성분도 비표면적이 증가하기 때문에, 해성분의 균일한 용출 및 감량을 위한 안정적인 조건을 선정하기가 어렵다. 본 연구에서는 코오롱FM에서 새롭게 개발한 800nm급 해도형 초극세사 제품의 감량특성에 대하여 고찰함으로써 제품화에 필요한 요소 기술의 기초를 마련하고자 한다. 유기산을 이용한 전처리가 해도형 초극세 폴리에스테르 섬유의 해성분 감량 특성에 미치는 영향에 대하여 조사하고, 알칼리 감량시 NaOH의 농도, 처리시간 및 처리온도별 감량특성에 대하여 고찰하였다.

  • PDF