• Title/Summary/Keyword: 전기주성

Search Result 173, Processing Time 0.034 seconds

DC-DC Boost Converter using Offset-Controlled Zero Current Sensor for Low Loss Thermoelectric Energy Harvesting Circuit (저 손실 열전변환 하베스팅을 위해 제로전류센서의 오프셋을 조절하는 부스트 컨버터)

  • Joo, Sunghwan;Kim, Kiryong;Jung, Dong-Hoon;Jung, Seong-Ook
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.373-377
    • /
    • 2016
  • This paper presents a low power boost converter using offset controlled Zero Current Sensor (ZCS) control for thermoelectric energy harvesting.[1] [5] Offset controlled ZCS uses adjustable pre-offset that is controled by 6bit code each connected gate of NMOS for switching. Offset controlled ZCS demonstrates an efficiency that is higher than using analog comparator ZCS and that is smaller area than using delay line ZCS. Experimentally, the offset controlled ZCS system consumes 10 times less power than analog comparator ZCS based system at similar performance.

Effect of Luminescence with Coactivator of $ZnGa_2O_4$:Mn,X phosphor ($ZnGa_2O_4$:Mn,X 형광체의 부활성제에 따른 발광 효과)

  • 박용규;한정인;주성후
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.3
    • /
    • pp.242-247
    • /
    • 1998
  • In this study, we have synthesized $ZnGa_2O_4$:Mn,X powder doped with Mn, MnO, $MnF_2$ and $MnCl_2$, low voltage green emitting phosphor, in vacuum atmosphere. From PL spectra, the intensity of the emission peak, the brightness with coactivator show that $ZnGa_2O_4$:Mn,Cl > $ZnGa_2O_4$:Mn,F > $ZnGa_2O_4$:Mn,O > $ZnGa_2O_4$:Mn. These improvement of the brightness are caused by the increase of the concentration of $Mn^{2+}$ ion. In case of $ZnGa_2O_4$:Mn,Cl and ZnGa$_2$O$_4$:Mn,F, the brightness is enhanced much more, which is owed to the decrease of defect of host material. For $ZnGa_2O_4$:Mn,Cl phosphor fabricated with optimized condition, the decay time becomes short from 30 ms of the $ZnGa_2O_4$:Mn and $ZnGa_2O_4$:Mn,O to 6 ms and the brightness of CL at 1 kV, 1 mA is 60 cd/$m^2$.

  • PDF

Brightness and chromaticity characteristics of ZnGa$_{2}$O$_{4}$:Mn,O phosphors (ZnGa$_{2}$O$_{4}$:Mn,O 형광체의 휘도 및 색도 특성)

  • 박용구;한정인;곽민기;한종근;주성후
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.262-267
    • /
    • 1997
  • In order to improve the brightness and chromaticity of green emitting low voltage phosphor for FED, we examine PL, PLE and CL emission characteristics of ZnGa$_{2}$O$_{4}$:Mn,O prepared in Ar and vacuum. ZnGa$_{2}$O$_{4}$:Mn,O sintered in vacuum shows about 16 times as bright as the one fabricated in Ar and excellent chromaticity. In PL emission spectra of ZnGa$_{2}$O$_{4}$:Mn,O at low temperature of 9 K, two peaks are observed at 504 nm and 513 nm. At room temperature, the two peaks are superimposed due to the lattice thermal vibrational energy, and only one peak is observed at 509 nm. From PLE measurements, it is believed that the energy levels of the host lattice and Mn ions are coexisted. The energy transfer from the host lattice to the emission center of Mn$^{2+}$ ions occurs.s.

  • PDF

Encapsulation Method of OLED with Inorganic Multi-layered Thin Films Sealed with Flat Glass (평판 유리로 봉인된 다층 무기 박막을 갖는 OLED 봉지 방법)

  • Park, Min-Kyung;Ju, Sung-Hoo;Yang, Jae-Woong;Paek, Kyeong-Kap
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.11
    • /
    • pp.905-910
    • /
    • 2011
  • To study encapsulation method for large-area organic light emitting diodes (OLEDs), red emitting OLEDs were fabricated, on which LiF and Al were deposited as inorganic protective films. And then the OLED was attached to flat glass by printing method using epoxy. In case of direct coating of epoxy onto OLED by printing method, luminance and current efficiency were remarkably decreased because of the damage to the OLED by epoxy. In case of depositing LiF and Al as inorganic protective films and then coating of epoxy onto OLED, luminance and current efficiency were not changed. OLED lifetime was more increased through inorganic protective films between OLED and flat glass than that without any encapsulation (8.8 h), i.e., 47 (LiF/Al/epoxy/glass), 62 (LiF/Al/LiF/epoxy/glass), and 84 h (LiF/Al/Al/epoxy/glass). The characteristics of OLED encapsulated with inorganic protective films (attached to flat glass) showed the possibility of application of protective films.

Performance Improvement of DC-link Control for a Dynamic Voltage Restorer with Power Feedforward Compensation (전력 전향보상을 통한 동적전압보상기 직류단 전압 제어의 성능 향상)

  • Ji, Kyun Seon;Jou, Sung Tak;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1297-1305
    • /
    • 2015
  • This paper proposes a power feedforward technique for the performance improvement of DC-link voltage control in the dynamic voltage restorer (DVR). The DC-link Voltage is able to be unstable for an instant owing to any change in the load and voltage sag. The distortion of the DC-link voltage leads to the negative influence on the performance of DVR. To mitigate the distortion of the DC-link voltage, the power feedforward component is calculated by the load power and the grid voltage, and then it is added to the reference current of the conventional DC-link voltage controller. By including output power feedforward component on the DC-link controller, the DC-link voltage can settle down more quickly than when the conventional DC-link voltage controller applied. The proposed technique was validated through the simulation and experimental results.

Design and Implementation of the Diseases Diagnosis System Using The Cantilever Micro-Arrays (박막 캔틸레버 어레이 센서를 이용한 질병 진단기 설계 및 구현)

  • Jung, Seung-Pyo;Choi, Jun-Kyu;Lee, Jung-Hoon;Park, Ju-Sung
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • The disease diagnosis system has been developed using the thin nitride(Si3N4) cantilever arrays which can measure the difference of capacitances between sensor and reference. The system consists of 32-bits RISC(Reduced Instruction Set Computer), RAM/Flash, bus, communication IP's, ADC(Analog Digital Converter) board, and LCD display. The marker selection method, which give us the good accuracy from reasonal numbers of markers, is suggested. The developed system has the resolution under 1fF and can detect 10nM concentration of Thrombin.

Emission Characteristics of White PHOLEDs with Different Emitting Layer Structures (발광층 구조에 따른 백색 인광 OLED의 발광 특성)

  • Seo, Jung-Hyun;Paek, Kyeong-Kap;Ju, Sung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.456-461
    • /
    • 2012
  • We studied the emission characteristics of white phosphorescent organic light-emitting diodes (PHOLEDs), which were fabricated using a two-wavelength method. To optimize emission characteristics of white PHOLEDs, white PHOLEDs with red/blue, blue/red and red/blue/red emitting layer (EML) structures were fabricated using a host-dopant system. In case of white PHOLEDs with red/blue structure, the best efficiency was obtained at a structure of red (15 nm)/blue (15 nm). But the emission color was blue-shifted white. In case of white PHOLEDs with blue/red structure, the better color purity and efficiency were observed at a blue (29 nm)/red (1 nm) structure. For additional improvement of color purity in white PHOLEDs with blue (29 nm)/red (1 nm) EMLs, we fabricated white PHOLEDs with red (1 nm)/blue (28 nm)/red (1 nm) structure. The current efficiency, external quantum efficiency, and CIE (x, y) coordinate were 27.2 cd/A, 15.1%, and (0.382, 0.369) at 1,000 $cd/m^2$, respectively.

Data Mining Technique Using the Coefficient of Determination in Holiday Load Forecasting (특수일 최대 전력 수요 예측을 위한 결정계수를 사용한 데이터 마이닝)

  • Wi, Young-Min;Song, Kyung-Bin;Joo, Sung-Kwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • Short-term load forecasting (STLF) is an important task in power system planning and operation. Its accuracy affects the reliability and economic operation of power systems. STLF is to be classified into load forecasting for weekdays, weekends, and holidays. Due to the limited historical data available, it is more difficult to accurately forecast load for holidays than to forecast load for weekdays and weekends. It has been recognized that the forecasting errors for holidays are large compared with those for weekdays in Korea. This paper presents a polynomial regression with data mining technique to forecast load for holidays. In statistics, a polynomial is widely used in situations where the response is curvilinear, because even complex nonlinear relationships can be adequately modeled by polynomials over a reasonably small range of the dependent variables. In the paper, the coefficient of determination is proposed as a selection criterion for screening weekday data used in holiday load forecasting. A numerical example is presented to validate the effectiveness of the proposed holiday load forecasting method.

A Study of Interface between Photovoltaic System and Utility Line using a Current-Source PWM Inverter based on Buck-boost topology (Buck-Boost 형태의 전류형 PWM 인버터를 이용한 태양광 발전과 계통연계에 관한 연구)

  • 주성용;양근령;강필순;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.36-42
    • /
    • 2003
  • This paper presents a new current-source PWM inverter based on Buck-boost configuration to interface between photovoltaic system and utility line. Proposed inverter is consisted by two set of buck-boost topology, and the input inductor is designed to be operated on the discontinuous current conduction mode. So high power factor can be achieved without additional input CtUTent controller. As a result, overall system has simple structure, and it can obtain higher ac output rms voltage than the terminal voltage of the photovoltaic system without additional boosting procedure. The operational modes are theoretically analyzed, and then the validity of the proposed system was verified through simulation and experimental results using a prototype.

Corona Discharge Phenomena on the Dielectric Electrodes in High Field (고전계하에서 유전체 전극에 나타나는 코로나 현상)

  • Kim, Jung-Dal;Lee, Duck-Jin;Joo, Sung-Cheol;Jung, Jang-Gun;Chang, Gi-Hyuk;Lee, Sae-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1598-1600
    • /
    • 1998
  • When dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents corona discharge phenomena on the dielectric in high field were studied under application of ${\pm}DC$ voltage, constitute of the point to plane 20mm gap. The results obtained in experimental are summarized as follow :(1) Corona pulse is appeared periodically after first corona pulse is occurred and the number of corona pulse increases with the instantaneous applied voltage but peak value is not changed greatly.(2)Applied voltage to beccrite and characteristics and peak value of current are almost a straight line. That kind of tendency accorded with characteristics of beccrite resistance.(3)In case of Positive corona, Positive streamers, were progressed greatly to plane electrodes but In case of negative corona, negative streamers smaller than that of Positive corona.

  • PDF