• Title/Summary/Keyword: 전기저항탐사

Search Result 532, Processing Time 0.027 seconds

Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments (저수지의 유지관리를 위한 전기비저항모니터링 기법 응용)

  • Park Sam Gyu;Kim Jung-Ho;Seo Goo Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The subject of this paper is research into the application of electrical resistivity monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity measurement, inclinometer, piezometer, and water gauge at an embankment. Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variant images of electrical resistivity at the embankment were provided from the monitoring data and we could accurately locate the portion of which resistivities have sharply changed. Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity data and hydrological data would be much more preferable to performing the just one-time measurements.

Application of Gold Exploration Using Three-dimensional Resistivity Inversion in Sambo mine (3차원 전기비저항 역산 방법을 이용한 삼보 광산에서 금광 탐사)

  • Park Jong-Oh;Kim Hee-Joon;Song Moo-Young;You Young-June
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.19-27
    • /
    • 2005
  • The Sambo mine is located in Hae-je Myeon, Moo-an Gun, Chollanamdo, which consists of host gneiss and rhyolite possessing quartzite veins with other compositions such as gold, silver, and sublimated sulfur. The ore grade estimated from the core was 0.05~10.9g/t or less in gold and 0.05~389g/t or less in silver, indicating a partial mineralization. The purpose of this paper is to understand the subsurface structures and the distribution of mineralized bodies in the Sambo mine using a combined method of Schlumberger, Wenner, and Dipole-di-pole resistivity surveys on the surface and the resistivity tomography survey in boreholes. The result of three-dimensional resistivity inversion showed that the mineralized body is extended to 240m long in the N10°~20°E direction, with 30m wide and 80 m thick from the surface. The low resistivity zones (<1,000ohm-m) determined from the resistivity image were in good agreement with the mineralized bodies and weak zones identified from the logged cores.

Cone resistance and electrical resistivity with Depth at Dredged Sea Sand Region (준설해사로 다짐된 방조제 제체 성토부의 콘저항치와 전기비저항 관계)

  • Song, Sung-Ho;Kang, Mi-Kyung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.37-40
    • /
    • 2008
  • We have measured resistivities for undisturbed soil samples collected from dredged bank with sea sand, and analyzed with one-dimensional inversion results from small-loop electromagnetic survey data. From the relationship between the two resistivities, it appeared that calculated resistivities were remarkably consistent with measured resistivities. Correlation relationships between resistivity values and cone resistance were analyzed after comparing inversion results with cone resistance. It turns out that the region with below 1 ohm-m is correspondent to that of with less than $50\;kgf/cm^2$ in dredged bank with sea sand. From the study result, resistivity monitoring of small-loop EM periodically is proved to be more effective to maintain the stability of embankment dike.

  • PDF

The Prototype Study of Resistivity and Porosity Measurement for the Samples Collected Near Marine Hydrothermal Deposit (해저열수광상 주변 암석 시료의 공극률과 전기비저항 측정 기초실험)

  • Lee, Sang-Kyu;Lee, Seong-Kon
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.378-387
    • /
    • 2010
  • We present the results of laboratory measurement of porosity and electrical resistivity for the samples collected near marine hydrothermal deposit to provide fundamental perspective of physical properties for future electromagnetic survey. The rock cores are sampled from the host rock, pumice, hydrothermal altered zone, and chimney. These samples are featured as easily brittle, rough surface with large pores, having components easily solvable in the water. We suggest systematic approach for measuring weights, volumes of core samples to calculate density and porosity. Measurements reveal that the resistivities of black host rock, gray host rock, pumice and chimney are 102, 39, 11, 0.1 ohm-m, respectively, when the core samples are saturated with saline water of $32,000\;{\mu}S$/cm (0.5 ohm-m) at temperature of $2.5^{\circ}C$ and these correspond to the factors of 5 for sea water, 110 for pumice and 390~1020 for host rocks with respect to the resistivity of chimney. We also confirm that resistivity of rock samples saturated with water decrease with temperature linearly over the temperature range of $20{\sim}80^{\circ}C$.

Electrical surveys at the Okmyung waste landfill of Pohang (포항 옥명 폐기물 매립장에서의 전기탐사)

  • Lee, Gi Hwa;Yun, Jong Ryeol
    • Journal of the Korean Geophysical Society
    • /
    • v.1 no.1
    • /
    • pp.41-50
    • /
    • 1998
  • Schlumberger soundings, dipole-dipole survey and electrical conductivity mappings were carried out inside and in front of the entrance of the Okmyung waste landfill in August, 1997 and January, 1998. Inside and in front of the landfill, 11 and 4 electrical soundings and 1 dipole-dipole survey were carried out, respectively. Electrical conductivities were measured at 164 points along the 4 lines in front of the entrance of the landfill. Interpretations of survey data show that low resistivity zones of 0.3∼3 Ωm extend down to 65 m depth from the surface in the 6th landfill, which indicates subsurface contamination by leachate and leachate level at 3∼6 m depth from the surface. In the 9th landfill, low resistivity zones below 2 Ωm appear at 11∼15 m depth from the surface, which indicates a very slim chance of subsurface contamination. On the other hand, electrical surveys and electrical conductivity mappings reveal low resistivities at shallow depths in front of the entrance of the landfill, indicating a high possibility of contamination of weathered zone in this area. It appears that southern part of this area close to the 6th landfill is more contaminated by leachate.

  • PDF

Interpretation of Vertical Electrical Sounding Data in Saltwater Intrusion Area using Geostatistical Method (지구통계분석을 이용한 해수침투지역에서의 전기비저항탐사 자료 해석)

  • Song Sung-Ho;Lee Gyu-Sang;Yong Hwan-Ho;Kim Jin-Sung;Seong Baek-Uk;Woo Myung-Ha
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.59-64
    • /
    • 2005
  • Although experimental analysis for groundwater sample at wells located systematically are very effective to delineate seawater intrusion region at coastal area, this method is restricted in few wells and time. We have conducted electrical resistivity sounding at 30 points in the study areas to analyze the region of seawater intrusion and found the boundary between salt wedge and fresh water lens from the analysis results of geostatistical method using variogram for one-dimensional inversion results. The methodology adopted in this study would be useful for finding the seawater intrusion region and evaluating quantitatively.

  • PDF

Electrical Resistivity Survey at the Ground with Micro-subsidence by Excessive Pumping of Groundwater (지하수 과잉양수에 따른 미세 지반변형 지역에서의 전기비저항 탐사)

  • Song Sung-Ho;Lee Kyu-Sang;Yong Hwan-Ho;Kim Jin-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.197-206
    • /
    • 2004
  • Because the minute displacement of ground accompanied by excessive pumping of groundwater at specified site is mainly generated from ill-balancing of water budget within groundwater basin, It is necessary to monitor the variation of micro-subsidence for a long time at representative points. We made up the conceptual model using two-dimensional electrical resistivity survey and three-dimensional soil profile consisted of loam and sand. In verifying the reliability of this conceptual model using numerical modeling for ground settlement and groundwater flowing, two-dimensional electrical resistivity survey with short distance of electrode following soil sampling with hand auger would be useful for interpreting hydrogeological structure related to the minute displacement of ground consisted of loam and sand.

Geoelectrical laboratory and field studies of groundwater occurrence in a landslide area: a case study from Japan (전기비저항탐사에 의한 산사태 지역의 지하수조사)

  • Park Sam-Gyu;Asano Shiho;Matsuura Sumio;Okamoto Takashi;Kim Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.86-91
    • /
    • 2005
  • We present the results of electrical resistivity surveys carried out to estimate the seasonal variation of the water table level in a large-scale landslide area of Tertiary geology in Japan. One long profile, trending NE-SW, was established perpendicular to the main regional geology of the region. Three boreholes are located very close to the profile. The profile was surveyed twice, once before snowfall and once after snow had melted. The relationship between resistivity and water saturation of pyroclastic materials was clarified through laboratory tests. We did this in order to estimate the water content of the pyroclastic layer from the observed resistivity distribution in the landslide area. The resistivity of the saturated pyroclastic deposit calculated using an empirical formula was found to be $570{\Omega}.m$. Based on this computed resistivity, the groundwater level was deduced by assuming that the pyroclastic deposits were fully saturated beneath the water table. We show that the estimated water table before snowfall is lower than that inferred after snow has melted, by about 1.1 to 4.7 m. This suggests that the water table in the upper part of the pyroclastic layer in the landslide area fluctuates greatly, compared to the lower part. This seasonal groundwater fluctuation is possibly caused by the infiltration of water into the subsurface after snowmelt.

Geometric Characteristics of Southern Yangsan Fault Zone by Means of Geophysical Prospecting and Geological Survey (지구물리탐사와 지질조사에 의한 양산단층대 남부구간의 기하학적 특성)

  • Lee, Hyoun-Jae;Hamm, Se-Yeong;Park, Samgyu;Ryoo, Chung-Ryul
    • The Journal of Engineering Geology
    • /
    • v.27 no.1
    • /
    • pp.9-20
    • /
    • 2017
  • To date, several studies have been carried out to partially compare and analyze the resistivity values within the Yangsan fault zone through the electrical resistivity survey of the exposed fault zone. However, it is not easy to directly observe a large scaled fault like Yangsan fault that has been weathered, especially due to the weathering of the fault core. This study aimed to reveal the characteristics of location, geometry, the fault core zone as well as underground distribution of the associated fault damage zone, based on the results of electrical resistivity and micro-topographic surveys as well as field geology survey in the southern Yangsan fault zone (Eonyang area). The resistivity anomaly zones developed in the NNE to NE direction were confirmed by the electrical resistivity survey. According to the electrical resistivity, micro-topographic, and field geologic surveys, the Yangsan fault has been formed by three to five fault cores, fault damage zones and/or fractured zones.

A Case Study of Electrical Resistivity and Borehole Imaging Methods for Detecting Underground Cavities and Monitoring Ground Subsidence at Abandoned Underground Mines (폐광산 지역의 공동 탐지 및 지반침하 모니터링을 위한 전기비저항탐사와 시추공영상촬영기법 적용 사례)

  • Choi, Jeong-Ryul;Kim, Seung-Sep;Park, Sang-Kyu;Shin, Kwang-Soo;Kang, Byung-Chun
    • Journal of the Korean earth science society
    • /
    • v.34 no.3
    • /
    • pp.195-208
    • /
    • 2013
  • We employed electrical resistivity and optical borehole imaging methods to identify underground cavities and determine ground subsidence rate at the study area affected by land subsidence due to abandoned underground mines. At the study site 1, the anomalous zones of low resistivity ranging between 100 ohm-meter and 150 ohm-meter were observed and confirmed as an abandoned underground mine by subsequent borehole drilling and optical borehole imaging. Although the electrical resistivity survey was unavailable due to the paved surface of the study site 2, we were able to locate another abandoned underground mine with the collapsed mine shaft based on the distribution of the ore veins and confirmed it with borehole drilling. In addition, we measured vertical displacements of underground features indicating underground subsidence by conducting optical borehole imaging 6 times over a period of 43 days at the study site 2. The displacement magnitude at the deep segment caused by subsidence appeared to be 3 times larger than those at the shallow segment. Similarly, the displacement duration at the deep segment was 4 times longer than those at the shallow segment. Therefore, the combination of electrical resistivity and optical borehole imaging methods can be effectively applicable to detect and monitor ground subsidence caused by underground cavities.