• Title/Summary/Keyword: 전기임피던스

Search Result 1,218, Processing Time 0.029 seconds

Method of deriving the acoustic impedance and sound absorption coefficient of materials by manipulating electrical impedance of a loudspeaker (스피커의 전기적 임피던스를 이용한 시료의 음향임피던스와 흡음계수 도출 기법)

  • Doo, Sejin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.254-260
    • /
    • 2021
  • When measuring the sound absorption coefficient of a specimen, a reverberation room which is costly or an impedance tube which has limitations in measuring low frequencies have been engaged. In this paper, a new measurement method of acoustic impedance or sound absorption coefficient has been suggested, which does not need microphones and only uses electrical impedance measurement data and derived Thiele/Small parameters of a speaker. The theory of this method has been described using equivalent circuit of the loudspeaker and acoustic properties of a test specimen are measured to demonstrate the validity of this method. It was confirmed that this method can easily measure the sound absorption coefficient in the low frequency band, which was previously difficult to trust. The advantages, limitations, and applicability of this method are discussed.

Application of the Electrical Impedance of Rocks in Characterizing Pore Geometry (암석 내 공극구조의 평가를 위한 전기임피던스의 적용)

  • Choo, Min-Kyoung;Song, In-Sun;Lee, Hi-Kweon;Kim, Tae-Hee;Chang, Chan-Dong
    • The Journal of Engineering Geology
    • /
    • v.21 no.4
    • /
    • pp.323-336
    • /
    • 2011
  • The hydro-mechanical behavior of the Earth's crust is strongly dependent on the fractional volume and geometrical structure of effective pore spaces. This study aims to understand the characteristics of pores using electrical impedance. We measured the electric impedance of core samples (diameter, 38-50 mm; length, 70-100 mm) of three types of granite (Hwangdeung, Pocheon, and Yangsan) and two types of sandstone (Boryung and Berea) with different porosities and pore structures, after saturation with saline water of varying salinities. The results show that resistance decreases but capacitance increases with increasing salinity of the pore fluid. For a given salinity, the resistivity and formation factor are reduced with increasing porosity of the rocks, and the capacitance increases. Berea sandstone shows anisotropy in resistance, tortuosity, and cementation factor, with these factors being highest normal to bedding planes. This result indicates that the connectivity of pores is weakest normal to bedding. In conclusion, the electrical characteristics of the tested samples are related not only to their porosity but also to the pore geometry.

플라즈마 임피던스를 이용한 RPS내 아노다이징 코팅진단 및 수명예측에 대한 연구

  • Kim, Dae-Uk;An, Yeong-O;Im, Eun-Seok;Lee, Han-Yong;Wi, Sun-Im;Choe, Dae-Gyu;Choe, Sang-Don
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.141.2-141.2
    • /
    • 2015
  • 교류임피던스 측정기법을 이용하여 전기화학적으로 외부환경에서 소재 금속까지 물질 및 전하이동에 관한 임피던스 측정이 가능하며 도막의 부식 및 노화정도 및 내식성의 평가가 가능하여 산업체에서 널리 이용되고 있다. RPCS(Remote Plasma Cleaning Source)는 패널 및 반도체 제조공정에서 CVD 증착공정 후 챔버 내부에 입혀지는 Si(실리콘)을 화학적으로 세정하기 위한 F(불소) Radical을 공급하는 원격 고밀도 플라즈마를 발생시키는 제품이다. RPCS의 바디는 알루미늄을 사용하고 절연 및 플라즈마에 대한 내구성을 확보하기 위해 아노다이징 코팅을 한다. 반응기 내벽의 표면이 공정 플라즈마에 노출될 때 소재는 화학적으로 매우 활성이 높은 라디칼과의 반응뿐만 아니라 이온의 충격을 동시에 받게 되며 이 과정에서 다량의 불소 (Fluorine) 라디칼과 전계에 반응한 이온의 운동에 노출되면서 아노다이징 코팅이 손상되는데 이는 기기의 수명 단축 및 파티클을 발생시키며, Arc의 원인이 되기도 한다. 실제 사용 환경에서는 기기의 분해 없이 아노다이징의 상태를 주기적으로 모니터링 하기가 대단히 어려워, 정기적으로 교체하고 있는 실정이다. 본 연구에서는 RPCS내 발생된 플라즈마 현상을 컨덕터로 활용하여 고주파 리액턴스를 임피던스로 환산하여 아노다이징 코팅의 손상 정도를 진단 및 모니터링하였다. 아노다이징이 손상된 내부 블럭과 정상상태인 내부 블럭의 임피던스를 비교하였고, 아노다이징 두께별 임피던스를 측정하였다. 그 결과 아노다이징 절연막이 손상된 블록의 임피던스가 정상 블록에 비해 낮았으며 두께별 임피던스도 비례함을 알 수 있었다. 향후에는 장기간 현장에서 축척되어진 시험데이터를 바탕으로 아노다이징 코팅의 수명예측진단 시스템을 구축하고자 한다.

  • PDF

Investigation and measurement of indoor low voltage powerline impedance for high data rate powerline communications (PLC) (고속 전력선 통신용 옥내 저전압 전력선 임피던스 측정 및 특성 연구)

  • 박영진;김관호
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.93-97
    • /
    • 2004
  • Since powerline for powerline communications (PLC) is designed for supplying electric power using 60 Hz wave, they will have different electrical behaviors for high data rate PLC whose bandwidth is allocated between 1 MHz and 30 MHz. Thus, it is necessary to investigate the different properties in this frequency bandwidth for the high data rate PLC. In this paper, low voltage (220V) powerline impedance for indoor high data rate PLC in between 1 MHz and 30 MHz is measured. For measurement a low voltage coupling unit is made and a vector network analyzer is used. A T-equivalent circuit of the low voltage coupling unit is obtained and then powerline impedance is derived by measuring the reflection coefficient of the total powerline network. With the method proposed, impedance is measured in case of a general korean apartment and its property is analyzed. Measurement shows that the average impedance is about 100Ω.

Study on Detection of Broken Rail Using Impedance Measurement (임피던스 측정을 통한 레일절손 검지에 관한 연구)

  • Kim, Jae Hee;Ahn, Chi-Hyung
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.190-195
    • /
    • 2017
  • This paper proposes a method to detect rail broken through impedance measurement. In general, broken rails are detected in real time using the track circuit, but the proposed method not only detects the broken rails but also estimates positions of broken areas by measuring the rail impedance. To electrically insulate one side of the rail, parallel resonance is made by adding a capacitor; then, the impedance of the other rail is measured. If the measured impedance has an inductive value, there is no broken area of rail. However if the measured impedance has a capacitive value, the rail is broken. The proposed method is modeled using a transmission line; it is shown that the modeling can estimate the position of the broken rail according to the impedance value. The rail impedance is measured by the proposed method for a 60m simple rail model, and it is verified that the presence of a broken rail changes the rail impedance.

Design and output control technique of sonar transmitter considering impedance variation of underwater acoustic transducer (수중 음향 트랜스듀서의 임피던스 변화를 고려한 소나 송신기의 설계 및 출력 제어 기법)

  • Shin, Chang-Hyun;Lee, Yoon-Ho;Ahn, Byoung-Sun;Yoon, Hong-Woo;Kwon, Byung-Jin;Kim, Kyung-Seop;Lee, Jeong-Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.481-491
    • /
    • 2022
  • The active sonar transmission system consists of a transmitter that outputs an electrical signal and an underwater acoustic transducer that converts the amplified electrical signal into an acoustic signal. In general, the transmitter output characteristics are dependent on load impedance, and an underwater acoustic transducer, which is a transmitter load, has a characteristic that the electrical impedance varies largely according to frequency when driven. In such a variable impedance condition, the output of the active sonar transmission system may become unstable. Hence, this paper proposes a design and control technique of a sonar transmitter for transmitting a stable transmission signal even under variable impedance conditions of an underwater acoustic transducer in an active sonar transmission system. The electrical impedance characteristics of the underwater acoustic transducer are experimentally analyzed, and the sonar transmitter is composed of a single-phase full-bridge inverter, an LC filter, and a matching circuit. In this paper, the design and output control method of the sonar transmitter is proposed to protect the transmitter and transducer. It can secure stable output voltage characteristics even if it transmits the Linear Frequency Modulation (LFM) signal. The validity is verified through the simulation and the experiment.

Development of Inverse Solver based on TSVD in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 TSVD 기반의 역문제 해법의 개발)

  • Kim, Bong Seok;Kim, Chang Il;Kim, Kyung Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.91-98
    • /
    • 2017
  • Electrical impedance tomography is a nondestructive imaging technique to reconstruct unknown conductivity distribution based on applied current data and measured voltage data through an array of electrodes attached on the periphery of a domain. In this paper, an inverse method based on truncated singular value decomposition is proposed to solve the inverse problem with the generalized Tikhonov regularization and to reconstruct the conductivity distribution. In order to reduce the inverse computational time, truncated singular value decomposition is applied to the inverse term after the generalized regularization matrix is taken out from the inverse matrix term. Numerical experiments and phantom experiments have been performed to verify the performance of the proposed method.

Construction of the Electrochemical Impedance Measurement System Using Fourier Transform (푸리에 변환을 이용한 전기화학적 임피던스 측정 시스템 제작)

  • Hwang, Eui-Jin;Oh, Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.713-719
    • /
    • 1991
  • Electrochemical impedance measurement system using Fourier transform was constructed in the range of the frequencies up to 100 kHz. This system consists of pseudo-random noise generator, specially designed potentiostat, fast data acquisition system, system controller, and computer interface. The performance of the constructed system was found to be almost same as the commercially available system using lock-in amplifier. Measuring time was significantly reduced because the minimum time for the measurement depended on one cycle of the lowest frequency used. It would be possible to study time-varying electrochemical impedance systems such as the initial stages of corrosion processes using this system.

  • PDF

The Decreasing of Surge Impedance of Grounding System by using Discharge (지중방전현상에 의한 접지시스템의 써지 임피던스의 저감)

  • 정재기;강지원;양병모;김홍필
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.55-61
    • /
    • 1998
  • Generally, in the calculation of ground resistance in the grounding system, the method measuring ground potential rise which is caused by low frequency source injection is used. But both lightning and surge impulse re very harmful to electric equipment. In this connection, this paper presents the results of an experimental investigation of transient behavior of ground impedances when lightening current is injected to the electric rod the experimental results are agreement with the theoretical analysis. In addition, the states on the behavior of ground electrodes under impulse currents due to lighting strokes are presented. And the impulse impedance reductions caused by discharge in the soils are presented.

  • PDF

Impedance Properties of Solenoid Coil for Electrodeldss lamp (무전극 형광램프 안테나 코일의 임피던스 특성)

  • Kim, Kwang-Soo;Jo, Ju-Ung;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.525-528
    • /
    • 2003
  • 유도결합형 플라즈마를 이용하는 무전극 형광램프는 소프트 페라이트를 이용하여 방전을 유도하며, 페라이트의 주파수나 온도 특성이 안정하면, 공심 솔레노이드코일을 사용하였을 때보다 램프저력이 더 효율적이 된다. 페라이트의 형상과 코일의 권선수는 코일의 임피던스, 인덕턴스, Q-factor에 직접적으로 영향을 주며, 감은 위치에 변화에 의해서도 그 값들이 변할 수 있다. 본 논문에서는 전구형 무전극 형광램프의 방전에 중요한 역할을 하는 안테나에 대한 실험 결과로서 Mn-Zn 페라이트를 이용한 솔레노이드 코일에 주파수와 코일의 권선수를 변화시켜 코일의 전기적 특성을 조사하였다. 임피던스 특성은 주파수가 증가함에 따라 증가하였으며, 코일의 권선수가 14회일 때, 기존 램프의 안테나와 비슷한 324[$\Omega$]을 나타내었으나, Q-factor는 코일의 권선수가 증가할 수 록 감소하였으며, 기존 램프의 안테나와 많은 차이를 나타내었다.

  • PDF