• Title/Summary/Keyword: 전기비저항 영상

Search Result 116, Processing Time 0.024 seconds

Assessment of Frozen Soil Characterization Via Electrical Resistivity Survey (전기비저항 탐사를 활용한 동결 지반의 거동 평가)

  • Jang, Byeong-Su;Kim, Young-Seok;Kim, Se-Won;Choi, Hyun-Jun;Yoon, Hyung-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.12
    • /
    • pp.115-125
    • /
    • 2023
  • In this study, we evaluated the behavior of frozen soil using an electrical resistivity survey method-a nondestructive technique-and examined its characteristics through field experiments. Frozen soil was artificially prepared by injecting fluid to accelerate the freezing process, and naturally frozen soil was selected in a nearby area for comparison. A dynamic cone penetration test (DCPT) was performed to compare the reliability of the electrical resistivity survey, and time-domain reflectometry surveys were performed to assess the moisture content of the ground. Field experiments were conducted in February-when the atmosphere temperature was below freezing-and May-when the temperature was above freezing. This temperature-compensated method was used to determine reliability because the behavior of frozen soil depends on the underlying temperature. In the resistivity survey method, a section of high electrical resistivity was observed under freezing conditions due to the frozen water and converted into porosity. The converted porosity was compared with the porosity inferred from the DCPT, and the results showed that the measured electrical resistivity was valid.

Resistivity Image Reconstruction Using Interacting Dual-Mode Regularization (상호작용 이중-모드 조정방법을 이용한 저항률 영상 복원)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.152-162
    • /
    • 2016
  • Electrical resistivity tomography (ERT) is a technique to reconstruct the internal resistivity distribution using the measured voltages on the surface electrodes. ERT inverse problem suffers from ill-posedness nature, so regularization methods are used to mitigate ill-posedness. The reconstruction performance varies depending on the type of regularization method. In this paper, an interacting dual-mode regularization method is proposed with two different regularization methods, L1-norm regularization and total variation (TV) regularization, to achieve robust reconstruction performance. The interacting dual-mode regularization method selects the suitable regularization method and combines the regularization methods based on computed mode probabilities depending on the actual conditions. The proposed method is tested with numerical simulations and the results demonstrate an improved reconstruction performance.

Sensitivity Analysis and Estimation of the Depth of Investigation in Small-Loop EM Surveys (소형루프 전자탐사의 감도분석 및 가탐심도 추정)

  • Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.299-308
    • /
    • 2002
  • We have derived an analytical expression for the sensitivity of the frequency domain small-loop electromagnetic (EM) surveys over a two-layer earth in order to estimate the depth of investigation with an instrument having the source-receiver separation of about 2 m. We analyzed the sensitivities to the lower layer normalized by those to the upper half-space and estimated the depth of investigation from the sensitivity analyses and the mutual impedance ratio. The computational results showed that the in-phase components of the sensitivity to the lower layer dominates those to the upper layer when the thickness of the upper layer is less than 20 m, while the quadrature components are not sensitive to the lower layer over the entire frequency range. Hence we confirmed that the accurate measurement of the in-phase component is essential to increase the depth of investigation in the multi-frequency small-loop EM survey. When conductive basement of 10 ohm-m underlies the upper layer of 100 ohm-m, an accurate measurement of the in-phase components ensures the depth of the investigation more than 10 m even accounting a noise effect, from which we conclude that the small-loop EM survey is quite effective in imaging the conductive plume down to a considerable depth. On the other hand, in the presence of the resistive basement of 1,000 ohm-m, the depth of investigation may not exceed 5 m considering the instrumental accuracy, which implies that the application of the small-loop EM survey is not recommended over the resistive environment other than detecting the buried conductor.

Hydrogeologic Structure derived from Electrical and CSMT Surveys in the Chojung Area (전기 및 CSMT 탐사를 이용한 초정지역의 수리지질 구조 해석)

  • Song Sung-Ho;Yong Hwan-Ho;Kim Jin-Ho;Song Seung-Yup;Chung Hyung-Jae
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.2
    • /
    • pp.118-125
    • /
    • 2002
  • The hydrogeologic structure in the Chojung area was evaluated from a set of geological and geophysical investigations: detailed geological survey, vertical electric sounding (VES), borehole logging, and controlled-source magnetotelluric (CSMT) survey. Among these, CSMT soundings were taken for integrated interpretation to extend hydrogeologic structure with depth. The result of CSMT survey along with VES and borehole logging provides the vertical geologic boundary connected with hydrogeologic structure, and also indicates the depth of aquifer in granite basement. To interpret the geologic boundary and aquifer characteristics using CSMT data, we adopted the technique of 1-D inversion with smoothness-constrained method and 2-D continuous profiling with 1-D Bostick inversion and spatial filtering. The methodology tested and adopted in this study would be useful and required for providing a more information to the structure of fractured aquifer system.

Geophysical surveys for delineation of leachate flows from AMD and buried rock wastes in Kwangyang abandoned mine (광양 폐광산의 산성광산배수의 유동경로 및 폐광석 탐지를 위한 지구물리탐사)

  • 김지수;한수형;윤왕중;김대화;이경주;최상훈;이평구
    • Economic and Environmental Geology
    • /
    • v.36 no.2
    • /
    • pp.123-131
    • /
    • 2003
  • Geophysical surveys(electrical resistivity, self-potential, seismic refraction, GPR) were conducted to investigate the physical properties of the subsurface, and to delineate the flow channel of leachate from a AMD(acid mine drainage), buried rock wastes and tailings, and drainage pipes at an abandoned mine(Kwangyang mine). Especially in rainy season the sites appear to be abundant in AMD leachate, characterized by electrical conductivities of 0.98-1.10 ms/S. Electrical resistivity sections indicate that the leachate flows running in two directions at southern part rise up through the narrow fracture zones at the central part and contaminates the surrounding soil and stream. Such schematic features at the anomalous zone are well correlated with negative peaks in self-potential data, the limited penetration depth in GPR data and low velocity zone in seismic refraction data. Shallow high-resistivity zone is associated with the buried rock wastes which cause the diffractions in GPR image. In addition, the events at depth of approximately 1-1.25 m in GPR sections must be the metal pipes through which AMD is drained off to the inner bay.

A Study on Geoelectrical Structure of Jeju Island Using 3D MT Inversion of 2D Profile Data (2차원 MT 자료의 3차원 역산을 통한 제주도 지전기구조 연구)

  • Choi, Ji-Hyang;Kim, Hee-Joon;Nam, Myung-Jin;Lee, Tae-Jong;Han, Nu-Ree;Lee, Seong-Kon;Song, Yoon-Ho;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.268-274
    • /
    • 2007
  • Traditional two-dimensional (2D) interpretation of magnetotelluric (MT) data utilizes only transverse magnetic (TM)-mode data, because 2D inversion of transverse electric (TE)-mode data results in spurious features when 3D structures exist in the subsurface. The application of a 3D inversion algorithm to a single MT profile can reduce contamination due to off-profile anomalies and help us to incorporate TE-mode data in the interpretation. In this study, we conduct 2D and 3D inversions of MT data observed along two lines in Jeju Island. First, we invert apparent resistivities and phases in the TM and TE modes separately. Then, we perform 2D joint inversion of both TM- and TE-mode data and 3D inversion of both Zxy- and Zyx-mode data corresponding to TE- and TM-mode data in 2D. The resistivity images derived from all four data show that the geoelectrical structure in Jeju Island is a three-layered earth with the resistive-conductive-resistive stratigraphy within a depth of 5 km. The 3D inversion does not produce clear anomalies in the reconstructed profile image, while all of 2D do. This attributed to the possibility that 2D inversion results are distorted by exiting off-profile 3D anomalies in Jeju. With 3D inversion of 2D profile MT data, we can deduce more reliable results that are not seriously distorted by off-profile 3D anomalies.

An Application of loop-loop EM Method for Geotechnical Survey (지반조사를 위한 loop-loop 전자탐사 기법의 적용)

  • You Jin-Sang;Song Yoonho;Seo1 Soon-Jee;Song Young-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.2
    • /
    • pp.25-33
    • /
    • 2001
  • Loop-loop electromagnetic (EM) survey in frequency domain has been carried out in order to provide basic solution to geotechnical applications. Source and receiver configuration may be horizontal co-planar (HCP) and/or vertical co-planar (VCP). Three quadrature components of mutual impedance ratio for each configuration are used to construct the subsurface image. For the purpose of obtaining the model response and validating the reasonable performance of the inversion, we obtained each responses of two-layered and three-layered earth models and two-dimensional (2-D) isolated anomalous body. The response of 2-D isolated anomalous body has been calculated using extended Born approximation for the solution of 2.5-D integral equation describing EM scattering problem. As a result of the least-squares inversion with variable Lagrangian multiplier, we could construct more resolvable image from HCP data than VCP data. Furthermore, joint inversion of HCP and VCP data made better stability and resolution of the inversion. Resistivity values, however, did not exactly match the true ones. Loop-loop EM field data was obtained with EM34-3XL system manufactured by Geonics Ltd. (Canada). Electrical resistivity survey was conducted on the same line for the comparison in advance. Since the constructed image from loop-loop EM data by 2-D inversion algorithm showed almost similar resistivity distribution to that from electrical resistivity one, we expect the developed 2.5-D loop-loop EM inversion program can be applied for the reconnaissance site survey.

  • PDF

Integrated Analysis of Electrical Resistivity Monitoring and Geotechnical Data for Soft Ground (연약지반에서의 전기비저항 모니터링 및 지반조사 자료의 복합 해석)

  • Ji, Yoonsoo;Oh, Seokhoon
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.16-26
    • /
    • 2015
  • To investigate the applicability of physical prospecting technique in soft ground assessment, the resistivity monitoring data of 6 months are acquired. The Multichannel Analysis Surface Wave (MASW) has been additionally performed to identify the shear wave velocity and strength distribution of soft ground. Moreover, by using the Cone Penetration Test (CPT) and laboratory tests of drilling samples, a relationship with the physical prospect data is checked and the reliability of the physical prospect data is increased. Through these activities, the behavior patterns of soft soil are identified by long term monitoring, and the significant relationship between the shear wave velocity and laboratory tests has been confirmed, both of which can be useful in the surface wave exploration to evaluate the strength of soft ground. Finally, using the geostatistical method, 3-dimensional soil base distribution images are obtained about the combined physical prospecting data with heterogeneous data. Through the studies, the nature of entire area can be determined by long term resistivity monitoring for the soft ground assessment in wider area. It would be more economic and reliable if additional exploring and drilling samples can be analyzed, which can reinforce the assessment.

불국사 석탑의 지반 특성에 대한 지구물리탐사

  • Seo, Man-Cheol;O, Jin-Yong;Choe, Hui-Su
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.2
    • /
    • pp.143-151
    • /
    • 2002
  • Bulku temple in the city of Kyungju, Korea, built in 791 and reconstructed in the 20th century, is the home of seven national treasures including two three-story stone pagodas, Dabotap (height 10.4m, width 7.4m, weight 123.2ton) and Seokgatap (height 10.8m, width 4.4m, weight 82.3 ton). An earlier archaeological investigation shows that stone pagodas have experienced severe weathering process which will threaten their stability. At the base part of Dabotap, an offset of the stone alignment is also observed. For the purpose of the structural safety diagnosis of two pagodas, we introduce the nondestructive geophysical methods. Site characteristics around the pagodas are determined by the measurement of multiple properties such as seismic velocity, resistivity, image of GPR(ground-penetrating radar). Near the pagodas, the occurrence of high resistivity (up to 2200 Ωm) is obvious whereas their outskirts have as low as 200 Ωm. For the velocity of the P wave, the site of Dabotap has the range of 500~800 m/s which is higher than counterpart of Seokgatap with the velocity of 300~500m/s, indicating the solider stability of Dabotap site. Consequently, in addition to GPR images, the foundation boundaries beneath each stone pagodas are revealed. The Dabotap site is in the form of an octagon having 6-m-long side with the depth of ~4m, whereas the Seokgatap site the 9m × 10m rectangle with the depth of 3m. These subsurface structures appear to reflect the original foundations constructed against the stone load of ~8 ton/㎡. At the subsurface beneath the northeast of each pagoda, low seismic velocity as well as low resistivity is prominent. It is interpreted to represent the weak underground condition.

  • PDF

3-D Geological Structure Interpretation by the Integrated Analysis of Magnetotelluric and Gravity Model at Hwasan Caldera (자기지전류 및 중력 모델의 복합해석을 통한 화산칼데라 지역의 3차원 지질구조 해석)

  • Park, Gye-Soon;Lee, Chun-Ki;Yang, Jun-Mo;Lee, Heui-Soon;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.32 no.6
    • /
    • pp.548-559
    • /
    • 2011
  • 3-D Multi-geophysical surveys were carried out around the Hwasan caldera at the Euisung Sub-basin. To overcome the limitations of resolutions in previous studies, dense gravity data and magnetotelluric (MT) data were obtained and analyzed. In this study, the independent inversion models from gravity and MT data were integrated using correlation and classification approaches for 3-D imaging of the geologic structures. A Structure Index (SI) method was proposed and applied to the integration and classification analyses. This method consists of Type Angle (TA) and Type Intensity (TI) values, which are estimated by the spatial correlation and abnormality of the physical properties. The SI method allowed the classification analysis to be effectively performed. Major findings are as follows: 1) pyroclastic rocks around the central area of the Hwasan caldera with lower density and resistivity than those of neighboring regions extended to a depth of around 1 km, 2) intrusive igneous rocks with high resistivity and density were imaged around the ring fault boundary, and 3) a basement structure with low resistivity and high density, at a depth of 3-5 km, was inferred by the SI analysis.