• Title/Summary/Keyword: 적절한 보강방법

Search Result 164, Processing Time 0.023 seconds

Development of Countermeasure Expert System for Tunneling Failure (터널 붕락특성과 시공 중 보강공법 선정방법 개발)

  • 김창용;박치현;배규진;홍성완;오명렬
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.171-181
    • /
    • 2000
  • Many Studies of tunnel and tunnelling safety have been developed continuously based on the increasing social interests in underground space since 1990's in Korea. Because the growth of population in metropolitan has been accelerated at a faster pace than the development of the cities, underground facilities have been created as a great extent in view of less land space available. In this study, a lot of types of tunnel failure were surveyed and the detail causes were studied after many cases of tunnel failure were collected. There were suggested brief countermeasure of tunnel failure through case study. An expert system was developed to predict the safety of tunnel and choose proper tunnel reinforcement system using fuzzy quantification theory and fuzzy inference rule based on tunnel information database. The comparison result between the predicted reinforcement system level and measured ones was very similar. In-situ data were obtained in three tunnel sites including subway tunnel under Han river. This system will be very helpful to make the most of in-situ data and suggest proper applicability of tunnel reinforcement system developing more resonable tunnel support method from dependance of some experienced experts for the absent of guide.

  • PDF

Development of Countermeasure Expert System for Tunneling Failure (터널 붕락특성과 시공 중 보강공법 선정방법 개발)

  • 김창용;박치현;배규진;홍성완;오명렬
    • Tunnel and Underground Space
    • /
    • v.10 no.3
    • /
    • pp.418-429
    • /
    • 2000
  • Many Studies of tunnel and tunnelling safety have been developed continuously based on the increasing social interests in underground space since 1990's in Korea. Because the growth of population in metropolitan has been accelerated at a faster pace than the development of the cities, underground facilities have been created as a great extent in view of less land space available. In this study, a lot of types of tunnel failure were surveyed and the detail causes were studied after many cases of tunnel failure were collected. There were suggested brief countermeasure of tunnel failure through case study. An expert system was developed to predict the safety of tunnel and choose proper tunnel reinforcement system using fuzzy quantification theory and fuzzy inference rule based on tunnel information database. The comparison result between the predicted reinforcement system level and measured ones was very similar. In-situ data were obtained in three tunnel sites including subway tunnel under Han river. This system will be very helpful to make the most of in-situ data and suggest proper applicability of tunnel reinforcement system developing more resonable tunnel support method from dependance of some experienced experts for the absent of guide.

  • PDF

A Study on Brace-height Ratio for Seismic Retrofit of School Building (학교 건축물의 내진 보강을 위한 가새 - 높이비에 관한 연구)

  • Lee, Hwa-Jung;Byon, Dae-Kun;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.10-17
    • /
    • 2020
  • The recent earthquake in Korea caused large and small damages to many school building. School building is an important building that is used as a shelter in the event of disaster. Among the seismic retrofit methods, the internal steel braced frame type method is used for its relatively easy construction and excellent performance. In this study, the maximum shear force and displacement were compared and examined by applying the brace frame to existing concrete school buildings. As a result, we verified the adequacy of the analytical model and compared and examined the effect of brace-height ratio on the span of the existing school buildings. The adequacy of the maximum shear force and displacement relationship can be confirmed in the model with a length of 0.3. In addition, seismic frame was applied to the actual non-seismic reinforced concrete school building, and the seismic performance was evaluated by nonlinear static analysis(Push-over analysis) according to the ratio of brace-height. As a result, the increase of the brace-height according to the brace-height ratio has the effect of increasing the maximum shear force and maximum load at the performance point. But the collapse of the braced frame due to the increase in the lateral stiffness occurred, indicating that seismic retrofit according to the proper brace-height is necessary. Therefore, in the seismic retrofit design of brace frame of existing school building, it is necessary to select the proper brace-height after retrofit analysis according to the brace-height ratio.

Stability Analysis of Soil Nailed Slope by Discrete Element Method (개별요소법을 이용한 지반네일에 의해 보강된 굴착사면의 안정해석)

  • 김주용;김준석
    • Geotechnical Engineering
    • /
    • v.11 no.4
    • /
    • pp.49-62
    • /
    • 1995
  • Soil nailing has been widely rosed during the last two decades to stabilize sheep excavated slopes in several countries. In thin study, the discrete element method has been applied to evaluate the stability of the reiuorced slope. This method is capable of not only estimat ins tensile and sheer stresses mobilized in nails but also providing individual safety factors of soil and nails, It has been assumed that the nailed slope be comprised of slices connected with elastoplastic twinkler springs. A reasonable mechanism is applied for representing the behavior between nails and adj scent soils. Taking into account for the bequence of construction the developed method well predicts the measured tensile forces developed in nails so that it is possible to appropriately evaluate the overall safety factor.

  • PDF

Optimum Design of Stiffeners in the Stiffened Cylindrical Shells Based on Structural Stability (좌굴을 고려한 원통쉘 보강재의 최적설계에 대하여)

  • 장창두;한성곤
    • Computational Structural Engineering
    • /
    • v.6 no.3
    • /
    • pp.81-88
    • /
    • 1993
  • An efficient approach to the buckling analysis of stiffened cylindrical shells with rings and stringers under the axial and the lateral pressure loadings is presented. By this approach, the local buckling as well as overall buckling behavior has been investigated considering the discreteness of stiffeners and appropriate adoption of displacement functions. Some design criteria based on structural stability to determine optimum scantlings of stiffeners are also suggested. It is shown that the optimum scantlings of stiffeners can be designed from the condition of equal local and overall buckling strength.

  • PDF

Load transfer test of circular anchorage system according to ETAG 013 (ETAG 013 규정에 따른 원형 정착구의 하중전달실험)

  • Kim, Bum-Joon;Kim, Hyun-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.167-175
    • /
    • 2018
  • Load transfer experiments have been carried out to evaluate the performance of the anchorage and it has been stated that the specimens were manufactured and tested according to ETAG 013. On the other hand, the amount of spiral reinforcement and auxiliary reinforcement exceeded the amount specified in ETAG 013. In this study, the load transfer test method and the criteria specified in ETAG 013 were considered and the PT anchorage system was applied to manufacture specimens with high strength concrete and a high tensile prestressing strand. A load transfer test according to ETAG 013 was performed to evaluate the performance of the circular anchorage. As a result, it was confirmed that ETAG 013 is a very strict specification that does not satisfy the performance of an anchorage unless the specimens of an appropriate size and spiral reinforcement are used. To assess the stability of the specimens, increasing the size of the specimen by 15%, rather than increasing the amount of auxiliary reinforcement, is considered to be the correct method in accordance with ETAG 013.

An Experimental Study on Flexural Strength of Modular Composite profiled Beams (휨 보강된 모듈단면 합성 프로파일보의 휨 내력에 관한 실험적 연구)

  • Ahn, Hyung Joon;Ryu, Soo Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.323-333
    • /
    • 2007
  • This paper presents a study that attempted to improve the site applicability of profile sheets and check the effects of bending reinforcement in composite profiled beams, and consequently, to suggest an improved modular-type CB2 and two types of bending reinforcement methods. As a result of the reinforcing and reforming modular profiled beam experiment conducted, CBIIshowed an adequate deformation capacity as well as a sufficient plastic plateau at the maximum load and thereafter. For all the specimens, an insignificant modular slip occurred while linear relations were kept constant, at up to approximately 50% of the maximum load and at constant linear relations. The experimental values were very low. Probably, due to the small-scale experiment, the area of the concrete for the concrete filling and covering might have been insufficient, which might have led to the failure to improve the strength. Comparing the results with the standard design stress, all the specimens-except for T16 and B16-indicated more than 0.9. Based on the standard design stress, the reinforced modular profiled beam was consideredto have positive applicability.

Structural Restoration for the Electric Power Transmission Tower Damaged by Foundation Settlements (기초침하에 의해 손상된 송전철탑 구조물의 구조성능개선)

  • Lee, Ho Beom;Park, Jong Kwon;Kim, Il Soo;Jang, Il Young;Song, Jae Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.83-93
    • /
    • 2013
  • Generally the capacities of electric power transmission tower's members are improved by increasing their stiffness nature through injection of grout or attachment of other structural stiffeners. Those are for upgrading their axial strength by fulfillment of proper materials into pipe members, increment of member dimension by addition of section, or a combination of the two. However the use of innovative and unusual procedures would be positively recommended for getting more stable state. It is that buckled members are replaced with lengthened and strengthened members. In providing the structural restoration procedures for the existing electric power transform tower whose main members have been damaged due to unequal foundation settlement, structural damage inspection works and numerical analyses for the damaged one and the restored one were done in detail at first. secondarily member-exchanging works using a newly-generated jacking system and strengthened members were achieved. This figures are to point clearly to inherent advantages attending the management of the towers.

Seismic Behavior and Performance Assesment of a One-story Building with a Flexible Diaphragm (유연한 지붕으로 된 단층 구조물의 지진 거동과 성능 분석)

  • ;;Donald W. White
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.4
    • /
    • pp.377-386
    • /
    • 2003
  • The proposed simplified MDOF model is applied to a half-scale single-story reinforced masonry test building with a single diagonally-sheathed diaphragm. Comparisons of analytical studies to experimental tests can be valuable for understanding the seismic response of these types of buildings and for determining the qualities and limitations of the simplified models. A model calibration process is performed in this paper to determine the required structural properties based on the elastic and inelastic test responses for test building. This approach is necessary since established methods to determine the in-plane and out-of-plane stiffness, strength, and hysteresis do not exist.

Steel Fiber Reinforcing Effect Analysis of Slab Panel Structure and Assessment Technics of Toughness (강섬유보강 패널구조의 보강효과 분석 및 인성평가 기법)

  • Jeon, Chan-Ki;Park, Sun-Kyu
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.209-220
    • /
    • 1999
  • This paper is aimed to evaluate the effectiveness of flexural toughness of slab panel structures($60{\times}60{\times}10$) reinforced by steel fiber instead of wire mesh. Steel fiber used in this study is double hooked Dramix type fiber. And the fiber length is 60mm, diameter is 0.8mm, Various assessment methods of toughness index are used to estimate the proper effectiveness. In this experimental study, we find that Johnston, JCI-SF4 and EFNARC method are more effective to assess the flexural toughness of slab panels than the others. And the steel fiber is very effective alternative material to reinforce slab panel structures instead of wire mesh. Fiber volume fraction of 0.5~0.75% is more useful than the others in enhancing the post-peak energy absorption and toughness index by Johnston's $I_{5.5}$ assessment method. And the slab panels reinforcing with steel fiber are more resistant to crack propagation than wire mesh reinforcing slabs.