• Title/Summary/Keyword: 적재하중

Search Result 70, Processing Time 0.026 seconds

Study on Live Loads in Office Buildings (사무실 적재하중의 통계적 조사 연구)

  • 김상효;조형근;배규웅;박홍석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.10a
    • /
    • pp.25-28
    • /
    • 1989
  • Live load data in domestic office buildings have been collected in a systematic manner. Based on surveyed data, equivalent uniformly distributed load intensities, which produce the same load effect as the actual spatially varying live load, have been obtained for various structural members(such as slab, beam, column, etc.). Influence surface method has been employed to compute load effects under real live load, inclucing beam moment, slab moment as well as axial force and moments in column. The results have been examined to find probabilistic characteristics and relationship between influence area and load intensity(or coefficient of variation). The results were also compared with other survey results and found to be reasonable.

  • PDF

Probabilistic Analysis of Design Live Loads on A Refrigeration Store (냉동 창고 상시 적재하중에 관한 확률론적 연구)

  • Kim, Dai-Ho;Jeong, Jae-Hun;Won, Young-SuI;Joo, Kyung-Jai
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.109-120
    • /
    • 2001
  • Live load data were collected with a systematic manner from a survey of a refrigeration stores. Using the collected floor live load survey data, the basic statistics, a histogram of the uniformly distributed loads, and the equivalent uniformly distributed loads are computed for various structural members. Based on the above results, the maximum values of a combined live loads during the design life have been estimated and compared with current design live loads. The ultimate goals of this study are to develop probabilistic live load models to analyze survey data of domestic refrigeration stores, and to propose design live loads for structural types.

  • PDF

Ultimate Strength Prediction Formula Estimation of Aluminium Alloy Plate Girders Subjected to Patch Loading (패치로딩을 받는 알루미늄 합금 플레이트 거더의 최종강도 예측식 추정)

  • Oh, Young-Cheol;Seo, Kwang-Cheol;Ko, Jae-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.5
    • /
    • pp.543-551
    • /
    • 2015
  • In this paper, Used on the bridge and ship, investigate the physical relationship of aluminium plate girders(A6082-T6) considering the marine environment. Plate girder will experience the patch loading such as moving load, surcharge in the product life cycle. The ultimate strength of aluminum plate girders subjected to these loads applied multiple numerical model and performed the elasto-plastic large deflection series analysis and was proposed the predicted formula for regression analysis. The predicted formula was shown by the relationship of ultimate strength and slenderness. If the slenderness is low(0-2.3), it causes a 9 % error, and If the slenderness is higher(2.3-4.0), it causes a 1-2 % error. Therefore, the propriety of proposed prediction formular was found to be assess rationally.

Establishment of Testing Method for Abutment Scour Stability by Real-scale Model Test (실대형 교각 실험을 통한 교각 세굴안정성 평가 실험 기법 정립)

  • Lee, Myungjae;Yoo, Mintaek;Kim, Kihyun;Lee, Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.7
    • /
    • pp.5-14
    • /
    • 2019
  • In this study, a prototype abutment was constructed to establish a safety assessment technique of pier and a series of non-destructive tests using impact load. The surcharge load was loaded from 0 tonf to 2.5 tonf on the prototype abutment, and maximum surcharge load was up to 25 tonf. To analyze the behavior of the piers according to the direction of impact, a total of three types of analysis were performed: the direction of the pier, the direction perpendicular to the pier, and the outer direction of the pier. The height of the impact was also tested at each top and bottom. The measuring instrument used an accelerometer to measure the acceleration response when impacted. Based on the series of experimental results, specific values were calculated according to the direction of an impact and the surcharge load using the Fast Fourier Transform (FFT). In addition, the phase difference was used to analyze the pier from the primary 1st mode to the 4th mode.

A Study on the Fire Resistance Performance of RC Structure Void Slab Using The Lightweight Hollow Sphere (경량 중공체를 적용한 RC조 중공슬래브의 내화성능에 관한 연구)

  • Cho, Bum-Yean;Yeo, In-Hwan;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.89-97
    • /
    • 2011
  • This study is for evaluating the fire resistance performance (1~2 h) of the RC Structure void slab using the Lightweight Hollow Sphere, which can reduce the unnecessary dynamic part of removing the central concrete. For this experiment, we set up depth of concrete cover, live load, and span length as the factors. The result comes out with all the slabs under those conditions can ensure the goal fire resistance performance (120 min). And among these factors, the resisting capability changes more sensitively with the live load rather than the thickness of cover. And the shorter span length could assure the better the fire resistance performance. The result observing the character in high temperature of the Lightweight Hollow Sphere which does not used as existing RC structure slab, a delay section in temperature change is occurred due to the Glass Transition in $100^{\circ}C$. And heat transfer by conduction does not occur at lightweight hollow sphere because the polystyrene in EPS (Expanded Polystyrene) melts point in $185^{\circ}C$. Therefore temperature at lightweight hollow sphere is lower than the concrete and rebar.

Study of Small Craft Resistance under Different Loading Conditions using Model Test and Numerical Simulations (모형시험과 수치해석을 이용한 하중조건 변화에 따른 소형선박의 저항성능 변화에 관한 연구)

  • Jun-Taek, Lim;Michael;Nam-Kyun, Im;Kwang-Cheol, Seo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.672-680
    • /
    • 2023
  • Weight is a critical factor in the ship design process given that it has a substantial impact on the hydrodynamic performance of ships. Typically, ships are optimally designed for specific conditions with a fixed draft and displacement. However, in reality, weight and draft can vary within a certain range owing to operational activities, such as fuel consumption, ballast adjustments, and loading conditions . Therefore, we investigated how resistance changes under three different loading conditions, namely overload, design-load, and lightship, for small craft, using both model experiments and numerical simulations. Additionally, we examined the sensitivity of weight changes to resistance to enhance the performance of ships, ultimately reducing power requirements in support of the International Maritime Organization's (IMO) goal of reducing CO2 emissions by 50% by 2050. We found that weight changes have a more significant impact at low Froude Numbers. Operating under overload conditions, which correspond to a 5% increase in draft and an 11.1% increase in displacement, can lead to a relatively substantial increase in total resistance, up to 15.97% and 14.31% in towing tests and CFD simulations, respectively.

Structural Behavior of Slab in the Partial Demolition for the Apartment Remodeling (아파트 리모델링을 위한 부분해체에서 슬래브의 구조적 거동)

  • Choi, Hoon;Joo, Hyung Joong;Kim, Hyo Jin;Yoon, Soon Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.19-30
    • /
    • 2012
  • Due to the fact that the social environment is improved and the urban development is stabilized, the demand of new construction of apartment becomes slowdown. Accordingly, there are many researches to lengthen the service life of the existing apartment through the remodeling and its importance is continuously rising. However, reliable design specifications and guidelines for the design of remodeling with partial demolition are not provided yet in Korea. Specially, in the apartment remodeling, slab collapse accidents take major portion in all accidents that reported by Korean Government. It is very important to prevent intial crack of slab because intial crack could cause severe accident like collapse of all structure in a short period of time. The purpose of this study is to develop structural guidelines that could guarantee the structural safety and serviceability of slab structure and could be adopted in Korean remodeling with partial demolition. There are mainly two components to determine structural behavior of slab structure. One is the shape of slab structure and the other is load which is resisted by the slab structure. In this study, the weight per unit volume of concrete debris and concrete strength are estimated through the analysis of previous researches to recognize the relationship between the shape of slab and load that loaded on the slab. Accordingly, approximately 300 pieces of floor plan are collected and analyzed. The finite element analysis is conducted using these analyzed and estimated results. From the finite element analysis results, the limited stacking height of debris is suggested and the stacking method is also discussed. In addition, to find the relationship between movement of demolition equipment and structural behavior of slab, the static and dynamic loading tests are conducted. From the results of loading tests, the impact factor which will be considered in the remodeling design could be estimated.

Development of Connection Model based on FE Analysis to Ensure Stability of Steel Storage Racks (적재설비 안정성 확보를 위한 FE 해석 기반의 연결부 모델 개발)

  • Heo, Gwanghee;Kim, Chunggil;Yu, Darly;Jeon, Jongsu;Lee, Chinok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.349-356
    • /
    • 2018
  • This paper attempts to develop a connection model based on FE analysis that can be applied to the evaluation of earthquake fragility of Steel Storage Racks lacking research in Korea. In order to accomplish this goal, shaking table tests, modal tests, and various member tests (8 case, push-over test) for structural members have been conducted to understand the behavior of steel storage racks. Based on the experimental results, detailed modeling of the joints was conducted using the NX-Nastran program in order to develop a connection model for Steel storage racks to be applied to the seismic vulnerability assessment. Especially, surface to surface contact element and spring element are applied to simulate the connection between the column member and the beam member connected by the simple latch method. Spring element model developed and applied ARX (Auto Regressive eXogenous) based mathematical model. The simulation results based on the FE model showed excellent reliability with a mutual error rate of less than 8% when compared with the member test results. As a result, it was confirmed that the FE model based connection model developed in the study can be applied to the analytical model for the seismic vulnerability assessment of Steel storage racks.

The Study on Table Deflection by Stationary State and Feedrate at Loaded (하중 적재시 정지상태 및 이송시 하중에 따른 테이블 처짐에 관한 연구)

  • Lee Seung Soo;Kim Min Ju;Kim Soon Kyung;Seo Sang Ha;Jeon Eon Chan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.6
    • /
    • pp.41-47
    • /
    • 2004
  • This study is aimed to measure the deflection of loaded table on machine tool. The deflection rate is measured then the table is in a stationary state and is moved. In conclusion we have found that the more load increases, the more the table deflections. Also, we have found that the deflection rate increases in accordance with the speed of movement. Therefore, we have concluded that inspection of machine tool should be done considering the weight of load and the speed of movement. However, since the condition of accuracy test for domestic brand of machine tool is defined as unloaded case, measures should be explored only for loaded case.

Development of the 6-DOF Electrical Motion Platform System for Helicopter Simulator (헬리콥터 시뮬레이터용 6자유도 전기식 운동구현장치의 개발)

  • Han, Dong-Ju;;Kim, Guk-Jae;Kim, Ok-Gu;Jeon, Hyang-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.12
    • /
    • pp.75-81
    • /
    • 2006
  • In this paper, the 6-dof electric motion platform system designed for the helicopter simulator satisfying the class of the CASA(Civil Aviation Safety Authority) level 2 is presented. From the kinematic, dynamic and structural analyses for motion base and electrical actuator systems, we show the feasibility of the developed motion platform system by producing the acceptable results of the test and evaluation according to the requirements specified in the CASA level 2. Furthermore through this development we suggest newly the adaptability of the electrical actuator system up to 10 ton class motion platform system, whose usage will be broaden rapidly, substituting with the advantage over the conventional hydraulic system.