• Title/Summary/Keyword: 적외선온도계

Search Result 21, Processing Time 0.033 seconds

비접촉시 적외선 온도계의 전기설비 유지보수(Electrical Maintenance)

  • 이상덕
    • Electric Engineers Magazine
    • /
    • v.254 no.10
    • /
    • pp.41-45
    • /
    • 2003
  • 비접촉식 적외선 온도계는 전기 설비의 문제점을 사전에 진담함으로써 부품 교체로 들어가는 비용을 절감하여주고 전기적인 서비스와 유지보수를 하는데 적외선 온도계를 사용함으로서 과열되는 부분을 바로 알 수가 있어 수리 및 비 가동 시간으로 인한 비용손실을 막을 수 있다.

  • PDF

Development of Infra-red system for temperature measurement of sub units of urban train (도시철도차량 하부장치 온도 측정용 적외선 방사온도계 개발 및 시험방법에 관한 연구)

  • Kim, Yong-Keun;Huh, Sung-Bum;Kwon, Seok-Jin;Lee, Hi-Sung
    • Journal of The Korean Society For Urban Railway
    • /
    • v.6 no.4
    • /
    • pp.243-248
    • /
    • 2018
  • The abnormally high temperature of the train part is related to train accidents and monitoring is important for safe operation of trains. In case of KTX an abnormality detecting device that detects the abnormality of the axle and scans the urban railway is installed on the railroad and when there is an abnormal heat generation, a system for automatically informing the control center is installed. The IR sensors module used in this system are depend on quick response. we have conducted a study on the fast response test method through the production of experimental equipments.

Establishment of Comparison Calibration Equipment for Infrared-radiation Thermometers Below ℃ (℃ 이하 적외선 복사온도계 비교 교정장치 구축)

  • Yoo, Yong Shim;Kim, Bong-Hak
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.2
    • /
    • pp.70-76
    • /
    • 2018
  • Comparison calibration equipment for infrared-radiation thermometers below $0^{\circ}C$ has been established, using a TRT2 (transfer radiation thermometer 2, HEITRONICS) as a transfer standard and an ME30 (Model: ME30, HEITRONICS) as a variabletemperature blackbody. The TRT2 was calibrated using three fixed points (Ice ($0.01^{\circ}C$), In ($156.5985^{\circ}C$), and Sn ($231.928^{\circ}C$)) and the Planckian Sakuma-Hattori equation, and including the interpolation and extrapolation errors at $-50^{\circ}C$ in the uncertainty. The pneumatic lid is installed upon opening of the ME30 and is opened for only 30 seconds for measuring the radiation temperature, which prevents formation of ice in the ME30 and also reduces the calibration time to half. The farther away from the $0{\sim}232^{\circ}C$ region, the larger the uncertainty of the comparison calibration equipment becomes. The expanded uncertainty of the comparison calibration equipment was estimated as 0.26 K at $-20^{\circ}C$.

초전형 적외선 센서(Pyroelectric Infrared Sensor)의 기술개요

  • 남선우;이범순;김두환;강영조
    • 전기의세계
    • /
    • v.41 no.2
    • /
    • pp.40-46
    • /
    • 1992
  • 광응용 분야는 광학, 전기, 전자 기술의 진보에 따라 괄목할만한 발전을 하고 있으며 그 응용폭 또한 넓다고 할 수 있겠다. 적외선 센서의 응용은 산업, 의학, 군사, 가전제품, 통신, 방재 등 다양하며 이 응용 분야 확대에 따라 센서의 고성능화 가격의 저렴화가 요구되므로 각분야에서 이른바 Intelligent화로의 연구가 활발한 실정이며 적외선 센서의 한 종류인 초전형 적외선 센서는 유전체에 조사되는 적외선에 의해 표면 전하가 변화하는 초전효과를 이용한 센서로서 이를 사용한 제품으로는 Human Detecting을 하는 Light control, Home Automation, 도난 경보기가 있으며, 화재 경보기, 가정용 조리기구, 비접촉식 온도계 등에도 사용되고 있다. 본 고에서는 광분야 중에서도 적외선 센서의 종류와 당사에서 개발하여 상품화시킨 초전형 적외선 센서에 대한 기술적인 개요와 응용분야를 기술하고자 한다.

  • PDF

Measurement of Temperature Distribution in the Infrared Panel Heater (적외선 패널히터의 온도분포 측정)

  • Lee, Kong-Hoon;Ha, Su-Seok;Kim, Ook-Joong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1178-1183
    • /
    • 2004
  • Temperature distribution and heating characteristic of the panel heater for infrared heating have been investigated. The temperature variation with time is firstly measured with the thermocouple to figure out the response time of the heater to the power input. The heater reaches faster to the steady state in comparison to the ceramic heater. The infrared thermal imaging system is utilized to investigate the temperature distribution over the heater surface. The measured thermal images show that the thermal boundary layer induced by the free convection near the heater surface affects the temperature distribution on the surface. The images also show the fairly good uniformity of the temperature distribution in the core region of the surface.

  • PDF

A study on the method for thermal imaging of each abdominal region (복부 영역별 체열 영상 획득 방법 연구)

  • Kim, Keun Ho;Choi, Woosu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.397-399
    • /
    • 2021
  • 한의사의 복진을 모사하는 진단기기와 이를 이용하여 질환과 변증을 분류하는 알고리즘을 개발하는 연구가 진행되고 있다. 본 연구에서 적외선 체열 영상과 접촉식 온도계로부터 구성되는 복부 영역별 체열 영상 시스템을 제시하였고, 복부 영역의 절대 온도를 보정하는 방법을 살펴보았다. 접촉식 온도계를 활용해 추가로 복부표면 온도를 측정하였고, 동시에 열화상 카메라로도 영상을 촬영하여, 동일위치에서 열화상 영상의 온도값과 접촉식 체온계의 온도값을 비교해 전체 열화상 영상을 보정하였다. ICC 값이 0.96으로 나와 높은 재현성을 보였다.

Size-of-source Effect and Self-radiation Effect of an Infrared Radiation Thermometer (적외선 복사온도계의 복사원 크기효과 및 자기복사효과)

  • Yoo, Yong-Shim;Kim, Bong-Hwak;Park, Chul-Woung;Park, Seung-Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.133-138
    • /
    • 2010
  • All radiation thermometers have a size-of-source effect (SSE) and a self-radiation effect (SRE). The SSE,defined as dependence of the detector signal of a radiation thermometer on the diameter of a source, is critically dependent on the wavelength since diffraction is the main cause. In this paper, we have measured the SSE and the SRE of TRT2 (Transfer Radiation Thermometer 2, HEITRONICS) widely used as a transfer standard in low and middle temperature range. At $300^{\circ}C$, The radiation temperature difference between the 60 mm diameter blackbody and 10 mm diameter blackbody due to the SSE was estimated to be $3.5^{\circ}C$ in low temperature mode ($8-14\;{\mu}m$) and $0.5^{\circ}C$ in middle temperature mode ($3.9\;{\mu}m$). In addition, the measured radiation temperature difference of the blackbody due to the SRE was found to be 110 mK when the body temperature change of TRT2 was set at $2.6^{\circ}C$.

Using Leaf Temperature for Irrigation Scheduling in Greenhouse (온실작물의 관개계획의 수립을 위한 엽온의 활용)

  • 이남호;이훈선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.103-112
    • /
    • 2001
  • The development of infrared thermometry has led many researchers to use plant temperatures, and specifically the temperature of the crop canopy in the field, for estimating the water stress of a crop. The purpose of this study was to evaluate the role of leaf temperature in irrigation scheduling. An experiment was carried out in a greenhouse with chinese cabbage. Leaf temperature was measured with infrared thermometry and evapotranspiration of the crop was measured by lysimeters. Influence of the difference between leaf temperature and air temperature on crop evapotranspiration was evaluated under varying water stress condition. A further objective was to evaluate the effect of other climatic variables on the relationship between evapotranspiration and temperature difference between leaf and air. A statistical model for estimating evapotranspiration using the temperature difference, relative humidity. and radiation was developed and tested. Crop water stress index was calculated using vapour pressure deficit and the temperature difference. Relations between the crop water stress index and crop evapotranspiration was tested. The index was closely related with evapotranspiration.

  • PDF

기판후면 온도 모니터링을 이용한 CIGS박막 하향 증착시스템 개발 및 그 소자로서의 특성 연구

  • Kim, Eun-Do;Cha, Su-Yeong;Mun, Il-Gwon;Hwang, Do-Won;Jo, Seong-Jin;Kim, Chung-Gi;Kim, Jong-Pil;Yun, Jae-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.443-443
    • /
    • 2014
  • CIS 박막을 제조하기 위한 방법으로 셀렌화(selenization)방식, MOCVD방식, 동시진공증발(co-evaporation)방식, 전착(electrodeposition)방식 등이 있으나, 이러한 방식을 이용하여 CuInSe2 박막을 제조하는 경우 어떤 방법으로든 다원화합물의 조성 및 결정성을 조절하기가 매우 어려운 단점이 있었다. 기판의 온도를 일정 온도로 유지하도록 하고, 증발원을 가열하여 이에 내포된 물질(이원화합물 또는 단일원소)을 증발시켜 기판에 증착이 이루어지도록 하거나, 기판의 온도를 승온시키고 구리 이원화합물을 내포한 증발원을 가열해 물질을 증발시켜 기판에 증착이 이루어지도록 하는 방법으로 기판에 박막이 형성되도록 한다. 기판의 대면적화로 인해 균일한 박막의 형성이 어려워지고 있으며, 이중 15% 이상의 고효율을 보인 방법은 3-stage process를 이용한 동시진공증발방식으로, Cu, In, Ga, Se 등의 각 원소를 동시에 진공 증발시키면서 조성을 조절하여 태양전지에 적절한 전기적, 광학적 특성을 가지는 Cu(In,Ga)Se2 (CIGS)박막을 증착시키는 방법이다. 일반적으로, 실험실에서 연구되고 있는 장비의 구조는 증발원이 아래에 장착되어서 상향 증착되는 방식이다. 본 연구에서 사용된 장비는 하향 증발원이 측면에 장착되어서 하향 증착되는 방식으로 구성하였다. 증착되는 면방향으로, 적외선온도계(pyrometer)가 설치된 시창(viewport)의 오염 등으로 인하여, 지속적인 공정이 이루어지기 힘든 점을 개선하여 증착기판의 후면에 적외선 온도계를 설치하여 기판의 온도변화를 감지하여 공정에 반영할 수 있도록 하였다. 본 연구에서는 하향식 진공 증발원, 기판후면 온도모니터링모듈 등을 개발 장착하여, CIGS 박막을 제조하였으며, 버퍼층은 moving 스퍼터링법으로 ZnS를 증착하였고, 투명전극층은 PLD(Pulsed Laser Deposition)를 이용하여 제조하였다. 가장 높은 광변환효율을 보인 Al/ZnO/CdS/Mo/SLG박막시료는 유효면적 $0.45cm^2$에 광변환효율 15.65 %, Jsc : $33.59mA/cm^2$, Voc : 0.64 V, FF : 73.09 %를 얻을 수 있었으며, CdS를 ZnS로 대체한 Al/ZnO/ZnS/Mo/SLG박막시료는 유효면적 $0.45cm^2$에 광변환효율 12.45 %, Jsc : $33.62mA/cm^2$, Voc : 0.59 V, FF : 62.35 %를 얻을 수 있었다.

  • PDF

Development of Radiation Thermometer using InSb Photo-detector (인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구)

  • Hwang, Byeong-Oc;Lee, Won-Sik;Jhang, Kyung-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF