• Title/Summary/Keyword: 적외선열화상 이미지

Search Result 8, Processing Time 0.028 seconds

Evaluation of Improvement of Detection Capability of Infrared Thermography Tests for Wall-Thinning Defects in Piping Components by Applying Lock-in Mode (적외선열화상 시험에서 위상잠금모드 적용에 따른 배관 감육결함 검출능력 개선 평가)

  • Kim, Jin Weon;Yun, Kyung Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1175-1182
    • /
    • 2013
  • The lock-in mode infrared thermography (IRT) technique has been developed to improve the detection capability of defects in materials with high thermal conductivity, and it has been shown to provide better detection capability than conventional active IRT. Therefore, to investigate the application of this technique to nuclear piping components, lock-in mode IRT tests were conducted on pipe specimens containing simulated wall-thinning defects. Phase images of the wall-thinning defects were obtained from the tests, and they were compared with thermal images obtained from conventional active IRT tests. It showed that the ability to size the detected wall-thinning defects in piping components was improved by using lock-in mode IRT. The improvement was especially apparent when detecting short and narrow defects and defects with slanted edges. However, the detection capability for shallow wall-thinning defects did not improve much when using lock-in mode IRT.

A Study on the Leakage Evaluation for Power Plant Valve Using Infrared Thermography Method (적외선열화상에 의한 발전용 밸브 누설명가 연구)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.110-115
    • /
    • 2010
  • This study was conducted to estimate the feasibility using thermal image measurement that is applicable to internal leak diagnosis for the power plant valve. Abnormal heating of valve surface associated with high temperature steam f10w toward valve outlet side in the condition of low temperature is a primary indicator of leakage problems in high temperature and pressure valves. Thermal imaging enables to see the invisible thermal radiation that may portend impending damage before their condition becomes critical. When steam flow in valve outlet side in the condition of low temperature is converted into heat transmitted through the valve body due to the internal leakage in valve. The existence of abnormally increasable leakage rate in the valve will result in abnormally high levels of heat to be generated that can be quickly identified with a thermal image avoiding energy loss or damage of valve component. From the experimental results, it was suggested that the thermal image measurement could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

The Study of Micro Crack Detection in Dissimilar Metal Weld Using a Variable Ultrasound Infrared Thermography (가변초음파 적외선열화상을 이용한 이종접합용접부의 미세균열 검출 연구)

  • Park, Jeong-Hak;Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.3
    • /
    • pp.215-220
    • /
    • 2015
  • As a nondestructive inspection technology currently in use, infrared thermography has gradually expanded its application range to industry. The method detects only defect areas by grafting ultrasound on a technique of detecting infrared energy emitted from all objects with absolute temperature of 0 K and converting this energy into thermography for inspection. Ultrasound infrared thermography has merits including the ability to inspect a wide area in a short time without contacting the target object. This study investigated the applicability of the technique for defect detection using variable ultrasound excitation inspection methods on samples of Terfenol-D, a magnetostrictive material with a tunable natural resonant frequency.

NDE of the Internal Hole Defect of Dental Composite Restoration Using Infrared Lock-In Thermography (위상잠금 열화상기법을 이용한 치과용 복합레진 수복재의 내부 홀 결함에 대한 비파괴평가)

  • Gu, Ja-Uk;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.40-45
    • /
    • 2013
  • The purpose of this study was to detect the pin hole defect of dental composite restoration using lock-in thermography method. Amplitude and phase images of the composite resin specimens were analyzed according to the lock-in frequency and the diameter of defect area. Through the amplitude image analysis, at lock-in frequency of 0.05 Hz, defect diameters 2-5 mm exhibited the highest amplitude contrast value between defective area and sound area. The lock-in frequency range of 0.3-0.5 Hz provided good phase angle contrast for the defect area. At lock-in frequency range of 0.5 Hz, defect diameter of 5 mm exhibited the highest phase contrast value. It is concluded that the infrared lock-in thermography method verified the effectiveness for detecting the pin hole defect of dental composite restoration.

Non-Destructive Diagnosis of Rotational Components of a Railway Vehicle Using Infrared Thermography and Pattern Recognitions (적외선열화상 이미지법과 패턴 인식을 이용한 철도차량 회전기기의 비파괴 진단)

  • Kwon, Seok Jin;Kim, Min Su;Seo, Jung Won;Kang, Bu Beong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.300-307
    • /
    • 2016
  • The faults in railway vehicle components may result in either the stoppage of the service and the derailment of the vehicle. Therefore, it is important to diagnose and monitor the main components of a railway vehicle. The use of temperature is one of the basic methods for the diagnosis of abnormal conditions in the rotational components of a railway vehicle, such as bearings, reduction gears, brake discs, wheels and traction motors. In the present study, the diagnose of the rotational components using infrared thermography and a pattern recognition technique was carried out and a field test was performed. The results show that this method of diagnosis using infrared thermography can be used to identify abnormal conditions in rotational components of a railway vehicle.

Defect Detection of Impacted Composite Tubes by Lock-in Photo-Infrared Thermography Technique (위상잠금 열화상기법을 이용한 복합재 튜브 충격 손상 결함 측정)

  • Kim, Kyoung-Suk;Jeon, So-Young;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.139-143
    • /
    • 2011
  • The problem of delamination of composite tubes by impact has been acknowledged in aerospace and automobile industry. Non-destructive testing(NDT) methods in composite material structure are important to evaluate reliability of composite structure. There are many kinds of NDT methods which can detect the inside defect of the composite material such as Infrared Thermography(IRT). Infrared thermal imaging of object is different from that of a defect, in heated composite tubes with an internal defect, and then location and size of a defect can be measured by the analysis of thermal imaging pattern. In this study, Lock-in Infrared thermography detect internal defects of Impacted composite tubes by the inspection of infrared lay radiated from the surface of composite tubes.

Measurement Uncertainty on Subsurface Defects Detection Using Active Infrared Thermographic Technique (능동 적외선열화상 기법을 이용한 이면결함 검출에서의 측정 불확도)

  • Chung, Yoonjae;Kim, Wontae;Choi, Wonjae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.341-348
    • /
    • 2015
  • Active infrared thermography methods have been known to possess good fault detection capabilities for the detection of defects in materials compared to the conventional passive thermal infrared imaging techniques. However, the reliability of the technique has been under scrutiny. This paper proposes the lock-in thermography technique for the detection and estimation of artificial subsurface defect size and depth with uncertainty measurement.

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.