• Title/Summary/Keyword: 저항저감

Search Result 367, Processing Time 0.045 seconds

Characteristics of Flow-Induced Noise in the Suction Nozzle of a Vacuum Cleaner with a Double-Blade Fan (이중 블레이드 팬이 장착된 진공청소기 브러쉬의 유동소음 특성)

  • Park, I-Sun;Sohn, Chae-Hoon;Oh, Jang-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.205-213
    • /
    • 2011
  • The characteristics of noise generation in the suction nozzle of a vacuum cleaner are analyzed numerically and experimentally. First, the flow resistance induced by each element in the suction nozzle of a vacuum cleaner with a double-blade rotary fan is investigated numerically and its relation with flow-induced noise and suction performance is examined in an anechoic room. The flow resistance and vorticity in the suction nozzle are calculated, and it is found that they are closely related to flow-induced noise and that the upper limit of noise reduction is only 4 dBA. This upper limit can be achieved by changing the design of the brush nozzle. Two methods for noise reduction by enlargement of flow-inlet area and by optimization of the number of blades are tested. Finally, the effects of each method are verified experimentally.

Determination of Optimal Mixture Proportion of Segregation Reducing Type Superplasticizer for High Fluidity Concrete (고유동 콘크리트용 분리저감형 유동화제의 최적배합비 결정)

  • 한천구;김성수;손성운
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.275-282
    • /
    • 2002
  • High fluidity concrete needs high dosage of superplasticizer to acquire sufficient fluidity and high contents of fine powder and viscosity agents to prevent segregation. But it requires high manufacturing cost and has difficult in quality control. Therefore, in this paper, determination of optimal mixture proportion of segregation type superplasticizer for high fluidity concrete and manufacturing high fluidity concrete by applying developed segregation reducing type superplasticizer are discussed using flowing concrete method. According to test results, as dosage of superplasticizer increases, it shows that fluidity and bleeding increase, while air contents and ratio of segregation resistance decrease. It also shows that adding viscosity agent into it reduce bleeding and improve segregation resistance. Dosage of AE agent into it containing viscosity agent recovers loss of air contents during flowing procedure. Combination of proper contents of superplasticizer, viscosity agent and AE agent make possible to develope segregation reducing type superplasticizer Compressive strength of high fluidity concrete applying flowing method with it is higher than that of base concrete. No differences of compressive strength between compacting methods are found.

Optimal Design for the Nose Shape of Commercial High-speed Train Using Function of Train Configuration (열차형상함수를 이용한 상용 고속열차 전두부 형상 최적설계)

  • Kwak, Minho;Yun, Suhwan;Park, Choonsoo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.4
    • /
    • pp.279-288
    • /
    • 2015
  • Using the Vehicle Modeling Function, which can model various 3D nose shapes, nose shape optimization is performed to reduce the aerodynamic drag of the KTX Sancheon. 2D characteristic shapes of the KTX Sancheon nose were extracted and a base model of the KTX Sancheon was constructed for design optimization using the Vehicle Modeling Function. The design space was constructed with the base model and does not violate the shape constraints of commercial trains. Through nose shape optimization with the Broyden-Fletcher-Goldfarb-Shanno algorithm, the aerodynamic drag of the optimized shape was reduced by 6% compared to that of the base model. The longer nose and sharper edge of the optimized shape weaken the vortices behind the last car and can reduce the aerodynamic drag.

Estimation of Stator Resistance by Kalman Filter (칼만 필터를 이용한 전동기의 고정자 저항값 검출 방법)

  • Hwang, Sang-Jin;Shin, Dong-Cheol;Lee, Dong-Myung
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.493-494
    • /
    • 2018
  • 전동기 제어에 있어서, 전동기의 상수 추정이 필요한 경우가 있다. 예를 들면 고정자 자속기준 벡터제어시에는 고정자 저항의 정보가 필요하다. 본 논문에서는 전동기의 고정자 저항값을 검출 기법을 제안한다. 데드타임의 영향을 제거하기 위하여, 차동 성분의 전압, 전류값을 사용하며, 측정 노이즈 둥에 따른 오차를 저감시키기 위해 Kalman Filter 알고리즘을 적용한다. 시뮬레이션을 통해 알고리즘의 타당성을 보인다.

  • PDF

A Study on Characteristics of Drag Reduction Additive under High Temperature Range (고온영역에서 계면활성제의 마찰저감 성능 특성에 관한 연구)

  • Cho, Sung-Hwan;Ryu, Jae-Sung;Jung, Sang-Hoon
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • Overall total length of hydraulic pipe to transport the hot water in the domestic district heating network is above 3,000 Km approximately. This long pipe network requires a lots of the transport pumping power by surface friction of fluid. In this study, the drag reduction(DR) of Amin Oxide $C_{18}$ as non-ionic surfactant according to the fluid velocity, temperature and surfactant concentration under the condition of above $80^{\circ}C$ fluid temperature were investigated experimentally. Results showed that new amin oxide $C_{18}$ surfactant had DR of maximum 30% in fluid temperature of $80^{\circ}C$ and had 15% DR in fluid temperature over $100^{\circ}$ under short time test condition. And amine oxide had 155 hours duration time to keep the DR characteristic in the fluid temperature of $80^{\circ}$ and 1000 ppm concentration. But duration time of DR was decreased when fluid temperature increased.

Electrical resistivity characteristics for cement specimens with TiO2 according to activated carbon content (활성탄 함유량에 따른 광촉매(TiO2) 시멘트 시편의 전기비저항 특성)

  • Kong, Tae-Hyun;Lee, Jong-Won;Ye, Ji-Hun;Ahn, Jaehun;Oh, Tae-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.5
    • /
    • pp.591-610
    • /
    • 2020
  • Concrete with activated carbon and titanium dioxide (TiO2) has been used to reduce the particulate matter (PM) in underground structures (e.g., tunnels) due to the high performance of nitrogen oxides (NOx) abatement. Damage (e.g. crack, spalling, or detachment) can be caused by the environmental and ageing effects on the surface of the particulate matter reduction concrete, installed on the tunnel lining. Therefore, it is important to evaluate the existence of spalling on the concrete surface for maintaining performance of NOx reduction. In this study, a basic research was performed for feasibility of spalling evaluation using electrical resistivity characteristics. Given the test results, the electrical resistivity was decreased as the ratios of activated carbon (0~15%) and TiO2 (0~25%) were increased for specimens. Under a dry condition, electrical resistivity of cement specimens, mixed with activated carbon and TiO2, was decreased up to 2.3 times, compared with the normal cement specimen. In addition, under saturation conditions (degree of saturation: 85~98%), electrical resistivity of cement specimens with activated carbon, was decreased up to 3.5 times, compared with the normal cement specimen. Regardless of the condition (dry or saturated), the difference of electrical resistivity values shows the range of 2.3~2.8 times between the mixing specimen (with activated carbon (15%) and TiO2 (25%)) and the normal cement specimen. This study can help to provide basic knowledge for spalling evaluation using the electrical resistivity on the surface of the particulate matter reduction concrete in tunnels.

Evaluation on Durability of High Performance Concrete with Expansive Additive and Shrinkage Reducing Admixture (팽창재와 수축저감제를 사용한 고성능 콘크리트의 내구성 평가)

  • Koh, Kyung-Taek;Kang, Su-Tae;Park, Jung-Jun;Ryu, Gum-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.205-211
    • /
    • 2006
  • The objective of this study was to evaluate the durability of low shrinkage high performance concrete(LSHPC), which was combined with expansive additives and shrinkage reducing admixtures. We tested for not only LSHPC but also high performance concrete(HPC) and normal concrete(NC) to be compared with the durability of LSHPC. HPC was made in the same water-binder ratio of LSHPC without expansive additives and shrinkage reducing admixture. As a result, it was found that LSHPC had higher compressive and tensile strength than that of HPC. LSHPC showed more excellent performance than HPC and NC in the case of resistance to chloride ion penetration and resistance to carbonation and also showed nearly 100 durability factor in the freeze-thawing test with 500 cycles. From the examination about the watertightness and the pore distribution, it was found that the durability of LSHPC was improved because its hardened cement paste is organized closer. So we can conclude that when LSHPC is applied to structures in field, it is possible to reduce the shrinkage and crack in concrete and improve the durability.

Determination of Passive Damping Resistor for Stability Improvement of Grid-Connected Inverter using an LCL Filter (LCL 필터를 사용하는 계통연계형 인버터의 안정도 향상을 위한 수동댐핑 저항 산정)

  • Jo, Jongmin;Shin, Chang-hoon;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.34-35
    • /
    • 2017
  • 본 논문은 LCL 필터를 사용하는 계통연계형 인버터의 전류제어 안정도 향상을 위해 수동댐핑 기법을 적용하였으며, 안정도 해석기법을 기반으로 댐핑저항을 산정하였다. 전류제어기는 동기좌표계 PI 제어를 적용하였고, 인버터 $1.5T_s$ 시지연 특성을 고려한 전류제어 모델링을 수행하였다. 개루프 함수의 이득특성을 통해 필터공진을 0dB로 저감하는 최소 댐핑저항을 도출하였으며, 보드선도와 근궤적법을 기반으로 전류제어 안정도를 보장할 수 있는 적용 가능한 댐핑저항을 산정하였다. 댐핑저항을 적용한 7kW 인버터 시뮬레이션 및 실험을 통해 안정도 향상 및 댐핑저항 산정의 타당성을 검증하였다.

  • PDF

A Basic study on the LLCL filter to Reduce Harmonic Current of Grid Connected Power Inverter (계통연계형 인버터의 고조파 전류저감을 위한 LLCL 필터에 관한 연구)

  • Hong, Chang-Pyo;An, Byoung-Woong;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk;Shin, Hee-Kuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.501-503
    • /
    • 2013
  • 계통 연계형 인버터에는 고조파 전류 저감을 위한 필터를 필요로 한다. 고조파 저감을 위한 필터로는 LCL 필터가 주로 사용되고 있다. 하지만 최근에 연구되고 있는 LLCL 필터의 경우 LCL 필터의 캐패시터 단에 직렬로 L을 추가한 형태로 LC 직렬공진을 통하여 LCL 필터에 비해 PWM 주파수 대역의 고조파를 좀 더 효과적으로 저감 할 수 있는 장점을 가지고 있다. 하지만 기존연구에서는 LLCL 필터의 공진을 억제하기 위한 댐핑 방법 및 효과가 고려되어 있지 않다. 본 논문에서는 PWM 주파수 고조파 저감효과는 댐핑저항이 없는 경우와 동일한 효과를 얻으면서, LLCL 필터의 공진을 효과적으로 억제하는 LLCL 필터를 제안하고, 그 타당성을 시뮬레이션을 통해 입증하였다.

  • PDF

Experimental Assessment of the Drag Reduction Efficiency of the Outer-layer Vertical Blades (외부경계층 수직 날의 저항저감효과에 대한 실험적 연구)

  • An, Nam-Hyun;Chun, Ho-Hwan;Lee, In-Won
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.5
    • /
    • pp.487-494
    • /
    • 2008
  • An experimental assessment has been made of the drag reducing efficiency of the outer-layer vertical blades, which were first devised by Hutchins (2003). The drag reduction efficiency of the blades was reported to reach as much as 30%. The assessment of the drag reducing efficiency is mainly restricted to the downstream region of the blades. Indeed, sufficient care has not been taken to such adverse effects as the increase in the wetted surface area and the flow disturbances due to the presence of the blades. In the present study, a series of drag force measurements in towing tank and circulating water channel has been performed toward the assessments of the total drag reduction efficiency of the outer-layer vertical blades.