• Title/Summary/Keyword: 저층건축물

Search Result 59, Processing Time 0.024 seconds

The Inelastic Behavior of High Strength Reinforced Concrete Tall Walls (고강도 철근콘크리트 고층형 내력벽의 비탄성 거동에 관한 실험 연구)

  • 윤현도;정학영;최창식;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.139-148
    • /
    • 1995
  • The test results from three one fourth scale models using high strength Reinforced Concrete $f_x=704\;kg/cm^2,\;f_y=5.830\;kg/cm^2$ are presented. Such specimens are considered to represent the critical 3 storics of 60-story tall building of a structural wall system in area of high seismicity respectively. They are tested under inplane vertical and horizontal loading. The main varlable is the level of axial stress. The amounts of vertical and horizontal reinforcement are identical for the three walls testcd. The cross-section of all walls is barbell shape. The aspectratio($h_w/I_w$) of test specimen is 1.8. The aim of the study is to investigate the effects of levels of applied axial stresses on the inelastic behavior of high-strength R /C tall walls. Experimental results of high strength R /C tall walls subjected to axial load and simulated sels rnic loading show that it is possible to insure a ductlle dominant performance by promotmg flex ural yielding of vertical reinforcement and that axial stresses within $O.21f_x$ causes an increase in horizontal load-carrying capacity, initial secant st~ffness characteristics, but an decrease in displacement ductility. energy dissipation index and work damage index of high strength K /C tall walls

Test Results on the Type of Beam-to-Column Connection using SHN490 Steel (SHN490강종의 보-기둥 접합부 형태에 따른 실험적 연구)

  • Kim, So Yeong;Byeon, Sang Min;Lee, Ho;Shin, Kyung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.311-321
    • /
    • 2015
  • In this study, an experimental study to evaluate the seismic performance of beam-to-column connection for medium and low-rise building was conducted. Five connections using SHN490 steel were made with test variables such as flange welded or bolted, web welded or bolted. Specimen SHN-W-W is web welded and flange welded type. Specimen SHN-W-B is web welded and flange bolted type. Specimen SHN-B-W is web bolted and flange welded type. Specimen SHN-B-B is web bolted and flange bolted type. Specimen SHN-EP is a connection with the end plate to the beam ends. Cyclic loadings was applied at the tip of beam following KBC2009 load protocol. The load vs rotation curves for different connection are shown and final failure mode shapes are summarized. The connections are classified in terms of stiffness and strength as semi-rigid or rigid connection. Energy dissipation capacities for seismic performance evaluation were compared.

Behavior of Hybrid Stud under Compressive Load (복합스터드의 압축 좌굴 거동)

  • Lee, Sang Sup;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.609-619
    • /
    • 2004
  • An investigation was conducted on the activities around Europe in order to solve the problem of the thermal bridging of steel studs, which had caused a significant disadvantage. This study included the following: diminishing the contact area between the studs and the sheathing, lengthening the heat transfer route, replacing the steel web with a less conductive material, and placing foam insulation in locations where the thermal shorts are most critical. Although energy efficiency is usually the focus of such foreign cases because their stud application is mostly limited to low-rise residential buildings, both structural and thermal performance are taken into consideration in this study because these target middle-story buildings. A hybrid stud composed of steel and polymer was also developed. This hybrid stud, which is 150 SL in size, is made of a galvanized steel sheet (SGC58) and a glass fiber reinforced polymer (GFRP) withepoxy bonding. A total of 32 specimens were manufactured. Its parameters comprise two types of connection detail,s: the thickness of steel (1.0mm and 1.2mm) and of the GFRP (4mm-4ply and 6mm-6ply), and the ratio of the length to the depth (L/D = 3, 6, 9, 12). Steel stud specimens with the same conditions were compared to the hybrid stud. The test revealed that in the case of the steel specimen with a thickness of 1.0mm, the maximum load of hybrid studs increased an average of 1.62 times comparedto that of the steel stud. In the case of the steel specimen with a thickness of 1.2mm, on the other hand, the average increase was 1.46times. All specimens showed full composite action until the collapse.

Seismic Performance Evaluation of Masonry Walls Retrofitted with Semi-buried Lattice Reinforcement (조적식 구조물의 부분 매입식 격자철근 보강기법의 내진 성능 평가)

  • Kim, Sang Hyo;Choi, Moon Seock;Park, Se Jun;Ahn, Jin Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.88-98
    • /
    • 2011
  • Masonry structure is a style of building which has been widely applied as residential facilities of low and middle stories, commercial and public facilities etc. But it is possible to destroy by loss of adhesive strength or sliding when lateral forces, such as earthquake, occurs. This study proposes a seismic retrofit method for masonry structure and its seismic performance is demonstrated by shaking table test. Two specimens per each shaking direction were made, having out-of-plane(weak axis) and in-plane(strong axis) direction. External load of 1 ton was also applied for each specimen during the test, to model the behavior of reinforced masonry wall. As a result of shaking table tests, it is shown that the specimen applying the proposed seismic retrofit method showed acceptable behaviors in both of Korea building design criteria(0.14g) and USA seismic criteria suggested by IBC(0.4g). However, it was observed that stiffness of the specimen toward out-of-plane was rapidly decreasing when seismic excitations over 0.14g were loaded. In comparison of relative displacements, maximum relative displacement of specimens which were accelerated toward out-of-plane with 0.4g at once was 29~31% of maximum relative displacement when specimens were gradually accelerated from 0.08g to 0.4g, while the maximum relative displacement of specimens accelerated toward in-plane has similar value in both cases. Therefore, it is concluded that the wall accelerated toward out-of-plane is more affected by hair crack or possible fatigues caused by seismic excitation.

Collapse Capacity Evaluation of Steel Intermediate Moment Frames Using Incremental Dynamic Analysis (비선형 증분동적해석을 통한 철골 중간모멘트 골조의 붕괴성능 평가)

  • Shin, Dong-Hyeon;Kim, Hyung-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.9-20
    • /
    • 2014
  • Steel intermediate moment frames (IMFs) have been generally used as seismic load resisting systems (SLRSs) of a building to provide resistances against strong ground shaking. However, most of low and mid-rise steel buildings in Korea were constructed during pre-seismic code era or before the introduction of well-organized current seismic codes. It has been recognized that the seismic performance of these steel IMFs is still questionable. In order to respond to such a question, this study quantitatively investigates the seismic capacities of steel IMFs. Prototype models are built according to the number of stories, the levels of elastic seismic design base shear and the ductilities of structural components. Also, the other prototype models employing hysteretic energy dissipating devices (HEDDs) are considered. The collapse mechanism and the seismic performance of the prototype models are then described based on the results obtained from nonlinear-static and incremental-dynamic analyses. The seismic performance of the prototype models is assessed from collapse margin ratio (CMR) and collapse probability. From the assessment, the prototype model representing new steel IMFs has enough seismic capacities while, the prototype models representing existing steel IMFs provide higher collapse probabilities. From the analytic results of the prototype models retrofitted with HEDDs, the HEDDs enhance the seismic performance and collapse capacity of the existing steel IMFs. This is due to the energy dissipating capacity of the HEDDs and the redistribution of plastic hinges.

Seismic Behavior of a Five-story RC Structure Retrofitted with Buckling-Restrained Braces Using Time-dependent Elements (시간종속요소를 이용한 5층 RC건축물의 비좌굴가새 보강에 대한 내진거동)

  • Shin, Ji-Uk;Lee, Ki-Hak;Lee, Do-Hyung;Jeong, Seong-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.11-21
    • /
    • 2010
  • This study presents seismic responses of 5-story reinforced concrete structures retrofitted with the buckling-restrained braces using a time-dependent element. The time-dependent element having birth and death times can freely be activated within the user defined time intervals during the time history analysis. The buckling-restrained brace that showed the largest energy dissipation capacity among the test specimens in previous research was used for retrofitting the RC buildings in this study. It was assumed that the first story of the damaged building under the first earthquake was retrofitted with the buckling-restrained braces considered as the time-dependent element before the second of the successive earthquakes occurs. Under this assumption, this paper compares seismic responses of the RC structures with the time-dependent element subjected to the successive earthquake. Subjected to the second earthquake, it was observed that activation of the BRB systems largely decreases deformation of the moment frame where the damage was concentrated under the first earthquake. However, damages to the shear wall systems were increased after activation of the BRB systems. Since the cumulative damages of the shear wall systems were infinitesimal compared with the retrofit effect of the moment frame, the BRB system was effective under the successive earthquake.

Luminance distribution of Illuminated Bridges by View Point (교량의 조망점에 따른 휘도분포 특성분석)

  • Choi, Yoon-Seok;Kim, Jeong-Tai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.73-78
    • /
    • 2005
  • 본 연구에서는 서울시 한강에 위치한 교량을 대상으로 다양한 조망점에 따른 경관조명의 물리량을 측정하고 그 특성을 분석함으로써 동일한 연구대상에 대하여 조망점이 달라졌을 때 나타나는 물리적 변화를 통해 경관조명분야의 물리량평가방법론의 새로운 접근방법론을 제시하는 것이 목적이다. 이를 위하여 연구대상의 선정은 교량구조형식에 따라 분류하고. 경관조명이 설치된 교량 17개소 중 다양한 조망점과 현장측정의 편리성 등을 고려하여 광진교(거더교), 올림픽대교(사장교), 동작대교(트러스교), 동작대교(아치교)를 연구대상으로 선정하였다. 조망점은 한강둔치를 이용하는 방문객들이 바라보는 투시뷰, 교량주변 건축물에서 바라보는 건물뷰 그리고 교량 위를 이동하면서 바라보는 주행뷰로 구분하였다. 이러한 연구방법으로 도출된 결과는 동일한 경관조명연출을 토대로 교량별 조망점에 따른 휘도측정 및 분석에서 측정되는 각도, 거리, 방향에 따라 정형화된 비율은 아니지만 휘도값에 있어서 차이가 있다는 것을 확인 할 수 있었으며, 투시뷰와 건물뷰는 동일한 교량 구성요소를 갖고 있어 상호간 비교 분석이 가능하고 경관조명평가 요소로서 그 기능을 담당 할 수 있다고 판단되며, 주행뷰는 교량형식과 가로등의 영향을 많이 받으므로 평가요소로써 조망점을 활용하기에는 조금 더 깊은 연구가 선행되어야 할 것으로 보인다. 따라서 경관조명을 평가함에 있어 다양하게 바라보는 조망점은 조명연출로 인한 시각적 인식에 차이를 유발시킬 수 있어 경관조명을 평가할 때 다양한 조망점의 설정이 보다 객관적이고 정확한 분석이 가능할 것으로 판단된다.ridinium의 분포는 chlorophyll-a농도와 밀접한 관련성이 있었다. 담수적조의 현존량은 상류지역에서 $8.5\;{\times}\;10^3\;cell\;mL^L{-1}$로서 많았고, 댐부근의 하류지역($4.4\;{\times}\;10^2\;cell\;mL^L{-1}$)으로 갈수록 감소하는 양상을 보였다. 또한, 담수적조의 원인종으로 규조류 Synedra acus와 남조류 Microcystis aeruginosa도 소량관찰되었다. 저수지의 수질 부영양화 현상은 기존 경사사면형 농경지를 기반으로 조성되었으므로 저층으로부터 풍부한 영양환경을 내재하고 있었고, 담수 초기에 발생할 수 있는 가능성을 포함하고 있었다. 또한 유입수량의 부족과 현재 수질개선을 위해 적용하고 있는 수중폭기시설등의 물리적인 영향도 직 ${\cdot}$ 간접적으로 작용하였을 것으로 추정되었다 따라서 향후 이에 대한 중장기적인 모니터링이 필요하였고 유역과 저수지의 통합적인 수질관리계획 이 요구되었다.group으로, 용존산소량, 전기전도도, pH, 인산염이 정점 3, 4, 5에서 같은 group으로 묶였다.유의적인 CAT 활성 증가효과가 나타났고, 간조직의 시토졸 1획분에서는 대조군 대비 15${\sim}$27%의 CAT 활성 증가효과가 인정되었다. 이상의 결과에서 목초액의 장기간 투여는 간조직 중의 활성산소의 억제효과뿐만 아니라 방어시스템으로서 활성산소 제거효소의 역할도 충실히 수행하여 노화를 효과적으로 예방하고 억제할 수 있을 것으로 기

  • PDF

Study on the Nonlinear Analysis Model for Seismic Performance Evaluation of School Buildings Retrofitted with Infilled Steel Frame with Brace (철골 끼움가새골조로 보강된 학교건물의 내진성능평가를 위한 비선형 해석 모델에 관한 연구)

  • Yoo, Suk-Hyeong;Ko, Kwan-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.65-72
    • /
    • 2022
  • Recently, damage to buildings due to earthquakes in Korea occurred mainly in school buildings and Piloti-type multi-family houses, highlighting the need for seismic retrofit for buildings of the same type. In the early days of the seismic retrofit project for school facilities, various patented methods using dampers as a ductile seismic retrofit method were applied without sufficient verification procedures. However, in 「School Facility Seismic Performance Evaluation and Retrofit Manual, 2021」, when the patented method is applied, it must be applied through a separate strict verification procedure, and instead, the strength/stiffness retrofit method was induced as a general method. In practice,when evaluating seismic performance for retrofit by infilled steel frame with brace, the analysis model is constructed by directly connecting only the steel brace to the existing RC member. However, if the frame is removed from the analysis model of the infilled steel frame with brace, the force reduction occurring on the existing RC member near the retrofit is considered to be very large, and this is judged to affect the review of whether to retrofit the foundation or not. Therefore, in this study, preliminary analysis with variables such as whether or not steel frame is taken into account and frame link method for the analysis model of RC school building retrofitted by infilled steel frame with brace and nonlinear analysis for actual 3-story school building was performed, and basic data for rational analysis model setting were presented by comparing preliminary analysis and pushover analysis results for each variable.

The Facade Improvement of Complexed Commercial Building Considering Open Signboard - Focused on Commercial district in Chnagwon - (옥외광고물 설치를 고려한 복합상업건물 입면개선 - 창원시 일반상업지구를 중심으로 -)

  • Yu, Jin-Sang;Seo, You-Seok
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.191-202
    • /
    • 2007
  • In these days, open signboard system is controlled by administrative policy and law, but there is no consideration for different types of building. As such, this study aims to propose planning criteria for streetside commercial buildings, such as elevation and mass design of buildings, layout of signboard attached to the building elevation with consideration for streetscape. In mass planning for streetside commercial buildings, the building type with front open space keeps lower open signboard density than the building type directly leading to the street. It is desirable that open signboard of lower floor part is attached by a horizontal type, open signboard of low medium floor part by a projected vertical type, open signboard of high medium floor part and roof part with a minumum attachment of open signboard. As for elevation planning relative to open signboard, it is desirable that an irregular wall type is more useful than a regular wall type to control open signboard. And in all cases, horizontal element facade has a handicap to control the quantity of signboard. If the building has a corner, the piloti should be used in the corner of lower story for smooth circulation of pedestrians and emphasizing the transparency of elevation. Specially, in the case of a round corner, the corner should be emphasized by the composition of high transparent mass.

  • PDF