• Title/Summary/Keyword: 저주파 피로

Search Result 23, Processing Time 0.022 seconds

Detection Performance Analysis of Underwater Vehicles by Long-Range Underwater Acoustic Communication Signals (장거리 수중 음향 통신 신호에 의한 수중 운동체 피탐지 성능 분석)

  • Hyung-Moon, Kim;Jong-min, Ahn;In-Soo, Kim;Wan-Jin, Kim
    • Journal of the Korea Society for Simulation
    • /
    • v.31 no.4
    • /
    • pp.11-22
    • /
    • 2022
  • Unlike a short-range, a long-range underwater acoustic communication(UWAC) uses low frequency signal and deep sound channel to minimize propagation loss. In this case, even though communication signals are modulated using a covert transmission technique such as spread spectrum, it is hard to conceal the existence of the signals. The unconcealed communication signal can be utilized as active sonar signal by enemy and presence of underwater vehicles may be exposed to the interceptor. Since it is very important to maintain stealthiness for underwater vehicles, the detection probability of friendly underwater vehicles should be considered when interceptor utilizes our long-range UWAC signal. In this paper, we modeled a long-range UWAC environment for analyzing the detection performance of underwater vehicles and proposed the region of interest(ROI) setup method and the measurement of detection performance. By computer simulations, we yielded parameters, analyzed the detection probability and the detection performance in ROI. The analysis results showed that the proposed detection performance analysis method for underwater vehicles could play an important role in the operation of long-range UWAC equipment.

Developments of Extremely Low Frequency Electric Field Sensor using Guided-wave Optical Modulator (광도파로형 초저주파(ELF) 전계계측 센서의 개발)

  • Choe, Yeong-Gyu;Kim, Mun-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.6
    • /
    • pp.1-7
    • /
    • 2002
  • The use of an asymmetric Mach-Zehnder interferometric amplitude modulator to measure a relatively low frequency electric field strength is described. The sensitivity of an electric field sensor using a Ti:LiNbO$_3$ optical modulator is strongly affected by the shape of a electrode(probe antenna). To measure the low frequency electric field, a probe antenna of wide effective area is more useful than the usual dipole antenna. As a proof of this, the optical modulator was fabricated with a plate-type probe antenna and the usefulness of this antenna tested for measuring low frequency electric field strength. Measurements were performed in the range 0.1V/cm to 60V/cm at 60Hz through 100KHz. Using a probe antenna of 10mm$\times$10mm, the output voltage of 10㎷ was measured with respect to the electric field strength of 0.1V/cm at 60Hz. By increasing the effective area of the probe antenna, better sensitivity is obtainable over the measured range.

Robust Controller Design and Analysis Using Disturbance Observer and Integral Control (외란 관측기와 적분제어기를 이용한 강인 제어기 설계 및 분석)

  • Park, Hong-Seob;Lee, Chung-Woo;Chung, Chung-Choo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.514-516
    • /
    • 2005
  • 압전 구동기(Piezo actuator)는 수 나노미터 수준의 위치정밀도와 고분해능을 가지고 있으나 비선형 특성인 히스테리시스(Hysteresis)는 정상상태에서 위치 오차를 발생하는 주요 원인이 된다. 현재까지 히스테리시스를 보상하기 위해 피 프 포워드 제어 방법, Pl 제어 방법, $H_{\infty}$제어 방법 등이 연구되어 왔지만 저주파 대역의 외란(disturbance)까지 고려하여 시스 템을 주파수 영역에서 설계, 분석하는 방법에 대한 연구는 미흡하였다. 본 논문은 압전 구동기의 위치 제어를 위한 제어기의 설계와 이를 주파수 영역에서 분석하는 내용을 다룬다. 제어기의 설계는 히스테리시스를 보상하기 위해 극점 배치 방법과 외란 관측기(Disturbance observer)를 기본으로 하였으며 적분제어를 적용하여 시스템 민감도(sensitivity)를 개선하였다. 시뮬레이션과 실험을 통하여 설계한 제어기가 히스데리시스에 대한 보상과 민감도의 개선에 효율적임을 검증하였다.

  • PDF

Muscle Fatigue Analysis by Median Frequency and Wavelet Transform During Lumbar Extension Exercises (요추신전운동 시 중앙주파수와 웨이브렛 변환을 이용한 근피로도 분석)

  • 장근;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.377-382
    • /
    • 2004
  • In the present study, thirteen healthy volunteers performed lumbar extension exercises at 48$^{\circ}$/s, loaded by 40, 50, 60kg(about 44, 55, 66% of maximum voluntary contraction). During the whole period of exercises, electromyographic(EMG) signal was measured in the erector spinae muscle in order to determine muscle fatigue. Using the wavelet transform, EMG signal was separated by various frequency ranges in the time-frequency domain, and muscle fatigue was analyzed, comparing with the results based on the median frequency(MDF). MDF shifted toward the lower frequency ranges with the muscle fatigue, showing a single characteristic frequency. On the other hand, wavelet transform of EMG signals resulted in increased power amplitude in lower frequency ranges(0-125Hz), and decreased power amplitude in higher frequency ranges(375-468Hz). This study reveals that the muscle fatigue during dynamic movement is explained better by wavelet analysis.

Relationships of Psychological Factors to Stress and Heart Rate Variability as Stress Responses Induced by Cognitive Stressors (스트레스에 대한 심리 반응 유형과 심박변이도의 관련성)

  • Jang, Eun Hye;Kim, Ah Young;Yu, Han Young
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.71-82
    • /
    • 2018
  • Stress involves changes in behavior, autonomic function and the secretion of hormones. Autonomic nervous system (ANS) contributes to physiological adaptive process in short durations. In particular, heart rate variability (HRV) analysis is commonly used as a quantitative marker depicting the ANS activity related to mental stress. The aim of this study is to investigate correlations between psychological responses to stress and HRV indices induced by the cognitive stressor. Thirty-three participants rated their mental and physical symptoms occurred during the past two weeks on Stress Response Inventory (SRI), which is composed of seven stress factors that may influence the status of mental stress levels. Then, they underwent the psychophysiological procedures, which are collected electrocardiogram (ECG) signals during a cognitive stress task. HRV indices, the standard deviation of R-R interval (SDNN), root mean square of successive R-R interval difference (RMSSD) and low frequency (LF)/high frequency (HF) ratio were extracted from ECG signals. Physiological responses were calculated stress responses by subtracting mean of the baseline from the mean of recovery. Stress factors such as tension, aggression, depression, fatigue, and frustration were positively correlated to HRV indices. In particular, aggression had significant positive correlations to SDNN, RMSSD and LF/HF ratio. Increased aggressive responses to stress correlated with the increases of all HRV indices. This means the increased autonomic coactivation. Additionally, tension, depression, fatigue, and frustration were positively associated with RMSSD reflecting increases in parasympathetic activation. The autonomic coactivation may represent an integrated response to specific cognitive reactions such as the orienting response.

Estimation of Motion-Blur Parameters Based on a Stochastic Peak Trace Algorithm (통계적 극점 자취 알고리즘에 기초한 움직임 열화 영상의 파라메터 추출)

  • 최병철;홍훈섭;강문기
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.281-289
    • /
    • 2000
  • While acquiring images, the relative motion between the imaging device and the object scene seriously damages the image quality. This phenomenon is called motion blur. The peak-trace approach, which is our recent previous work, identifies important parameters to characterize the point spread function (PSF) of the blur, given only the blurred image itself. With the peak-trace approach the direction of the motion blur can be extracted regardless of the noise corruption and does not need much Processing time. In this paper stochastic peak-trace approaches are introduced. The erroneous data can be selected through the ML classification, and can be made small through weighting. Therefore the distortion of the direction in the low frequency region can be prevented. Using the linear prediction method, the irregular data are prohibited from being selected as the peak point. The detection of the second peak using the proposed moving average least mean (MALM) method is used in the Identification of the motion extent. The MALM method itself includes a noise removal process, so it is possible to extract the parameters even an environment of heavy noise. In the experiment, we could efficiently restore the degraded image using the information obtained by the proposed algorithm.

  • PDF

Leak Detection and Evaluation for Power Plant Boiler Tubes Using Acoustic Emission (음향방출을 이용한 보일러튜브 누설평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.45-51
    • /
    • 2004
  • Boiler tubes in power plants are often leaked due to various material degradations including creep and thermal fatigue damage under severe operating conditions such as high temperature and high pressure over an extended period of time. To monitor and diagnose the tubes on site and in real time, the acoustic emission (AE) technology was applied. We developed an AE leak detection system, and used it to study the variation of AE signal from the on-site tubes in response to the changes in the boiler operation condition and to detect the locations of leakage based on it. Detection of leak was performed by acquiring and evaluating the signals in separate regimes of high and low frequency signal. As a result of these studies, we found that on-line monitoring and detection of leak location for boiler tubes is possible using the developed system. Thus, the system is expected to contribute to the safe operation of power plants, and prevent economic losses due to potential leak.

Effects of Temperature and Stress Ratio on Low-Cycle Fatigue Crack Growth of G91 Steel (G91강 저주파 피로균열 성장에 미치는 온도와 응력비의 영향)

  • Kim, Jong Bum;Hwang, Soo-Kyung;Kim, Bum Joon;Lee, Jong Hoon;Park, Chang Gyu;Lee, Hyeong Yeon;Kim, Moon Ki;Lim, Byeong Soo
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.4
    • /
    • pp.271-279
    • /
    • 2012
  • 9-12% Cr steels have been used in thermal power plants which repeat start and stop operations. Major factors of fatigue life are temperature, frequency, stress ratio, holding time, microstructure, and environment. Normally, fatigue life decreases at high temperature, low frequency, high stress ratio, and long holding time conditions. A Mod.9Cr-1Mo steel, called G91, was developed at ORNL (Oak Ridge National Laboratory, USA) and was adopted as a high-temperature structural material in the ASME Code in 2004. However, its low-cycle fatigue and fatigue crack growth characteristics have been rarely studied. In this work, we have investigated the low-cycle fatigue crack growth behaviors of G91 steel under various test conditions in terms of temperature and stress ratio. As temperature and stress ratio increase, the crack growth rate becomes faster and striation distance also increases. On the other hand, the number of branch cracks decreases.

Study on the control of VCM and its application to the vibration isolator (VCM의 제어 및 제진 장치 응용에 관한 연구)

  • Kim, Jin-Man;Nam, Taek-Kun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • The degradation of durability and increase of fatigue on the ship are mainly caused by vibration of the engine and rotating machineries. The damper to minimize the influence from vibration is usually attached between the machineries and its base. General damper applied on the vessel is passive damper which is designed to attenuate specified frequency signals, i.e, high frequency vibration signals. But it is hard to anticipate its performance for low frequency signals. In this research, active vibration isolator using VCM is developed to suppress wide band vibration signals. Routh-Huritz's stable condition, ultimate sensitivity method and parameter tuning are applied to derive PID parameters and 2 and 4 phase choppers are also adapted to drive VCM. Simulation and experiments are executed to confirm the effectiveness of the proposed control schemes.

Bioelectrical Impedance Analysis of Multi-frequency using Portable Small Impedance Measuring System (휴대용 소형임피던스 측정시스템을 이용한 다중주파수의 생체임피던스 해석)

  • Kim, Min Soo;Cho, Young Chang
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.2
    • /
    • pp.121-126
    • /
    • 2017
  • In this study, we measured the bioelectrical impedance of whole body in various frequency bands by non-invasive method by four electrode method using a portable small impedance measurement system developed to understand the bioimpedance characteristics of intracellular fluid and extracellular fluid components through a skin equivalent model. The measurements were performed on 10 male subjects (mean age $24{\pm}3.0$, body mass index(BMI) $20.3kg/m^2$) for four weeks and the bioimpedances were measured at multi-frequencies (1 kHz, 5 kHz, 50 kHz, 70 kHz, 100 kHz and 500 kHz). Experimental results show that the impedance is the highest in the low frequency range of 1 kHz and the lowest in the high frequency range of 500 MHz. Especially, it was confirmed through experiments that the impedance is rapidly lowered above 50 kHz band. In addition, it was confirmed that similar characteristics to the measured values of the bioimpedance measuring system were obtained in the simulations for understanding the impedance characteristics of the intracellular fluid and the extracellular fluid through the skin equivalent circuit model.