• 제목/요약/키워드: 저압 케이블

검색결과 27건 처리시간 0.027초

SSTDR에서 시간-주파수 상관을 활용한 저압 케이블의 고장 검출 (Fault Detection of Low Voltage Cable using Time-Frequency Correlation in SSTDR)

  • 전정채;김택희;유재근
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.498-504
    • /
    • 2015
  • This paper proposed an Spread Spectrum Time Domain Reflectometry (SSTDR) using time-frequency correlation analysis in order to have more accurate fault determination and location detection than classical SSTDR despite increased signal attenuation due to the long distance to cable fault location. The proposed method was validated through comparison with classical SSTDR methods in open- and short-circuit fault detection experiments of low-voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.

저압 지중케이블의 토양 열저항률 적용에 관한 연구 (A Study on the Apply to Soil Thermal Resistivity of Low-Voltage Underground Power Cables)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.65-70
    • /
    • 2012
  • The current-carrying capacities in IEC standards for underground refers to a soil thermal resistivity of 2.5[$K{\cdot}m/W$] where no measured data are available. But this value is considered too conservative and may not justifiable economically as to need precaution in using the value. In this paper, the standard practices on the application of soil thermal resistivity of some countries(UK, USA etc) are surveyed and proposed a reasonable representative value 1.0[$K{\cdot}m/W$] of soil thermal resistivity considering the domestic soil thermal properties with regard to the application of IEC standard.

맨홀용 및 핸드홀용 지중 저압케이블 접속장치 개발 (Development of connection device for underground low voltage cable of manhole and handhole)

  • 이강중;이은정;주종민;유근양
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1056-1058
    • /
    • 2005
  • It shows a tendency to increase rapidly underground of the city due to the build up of the large residential districts with industrial development, so there is required the development of the connection device for underground low voltage cable with high quality & convenient for use with consideration for installation condition of the underground. Hence, We will have the development of the connection device for underground low voltage cable, which is made waterproof perfectly under the flood of the underground for the long time, is convenient for use in spite of narrow area such as manhole or handhole, and can be able to prevent the release by the vibration.

  • PDF

ACB 기중아크의 아크전압 분석 (Analysis of Voltage of Arc in Air at ACB)

  • 송태헌;권중록;곽철희;권기정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1438-1439
    • /
    • 2007
  • 저압기중차단기의 한류성능 분석 및 개선을 위해서는 ACB에서 발생하는 아크전압에 대한 정보가 필요하다. 그러나 아크의 비선형적 특성 때문에 이론적 접근에는 한계가 있으므로, 실험적 접근을 통해 아크전압을 계측하고 분석하였다. 고온고압하의 아크 발생 환경에서 소호그리드간의 아크전압을 측정하기 위해서 열적, 절연적 특성이 우수한 테플론 피복 케이블을 적용하였다. 소호그리드의 배치를 변화시켜 가면서 입출력 단자간 전압과 소호그리드간 전압을 측정하고 분석하였다. 이와 같은 연구를 통해 소호그리드의 아크전압상승 영향에 대한 기초적인 결과를 얻을 수 있었다.

  • PDF

IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰 (Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364)

  • 김두웅;류규상;김한수;신대성;류기환;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

퍼지 분류기 기반 지능형 차단 시스템 (Intelligent Diagnosis System Based on Fuzzy Classifier)

  • 성화창;박진배;소제윤;주영훈
    • 한국지능시스템학회논문지
    • /
    • 제17권4호
    • /
    • pp.534-539
    • /
    • 2007
  • 본 논문에서는 저압 배선 진단 시스템 개발을 위한 지능형 차단 시스템을 제안한다. 제안된 배선 진단 시스템은 TFDR(Time-Frequency Domain Reflectometry) 알고리즘을 통해 배선이 어떤 상태인지를 보여 주는 시스템이다. 그리고 제안된 진단 시스템으로부터 얻은 신호를 분석하여 이상 종류에 따라 분류하는 시스템을 통해 지능형 차단 시스템을 제안한다. 일반적으로, TFDR을 통해 알아 낼 수 있는 이상의 종류는 damage, open 그리고 short 이다. 각 상황에 대한 효율적인 분류를 위하여 IF-THEN 규칙에 기반 한 분류기가 사용된다. 기존 TFDR이 수행되었던 통신선 케이블의 실험 데이터에 기반 한 실험을 통해 본 제안 내용의 우수성을 보이게 된다.

탄소섬유를 이용한 600V 이하 저압 케이블의 전자파 차폐특성 (The Electromagnetic Shield Properties of 600V class Low Voltage Cable Using Carbon Fiber)

  • 김영석;김택희;김종민;송길목;김지연;김원석;곽동순
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.243-248
    • /
    • 2017
  • This study used general carbon fibers(CF), which can be utilized for a low voltage cable screen, as well as metal-coated carbon fibers(MCF) to make cables and analyzed the properties of electromagnetic effectiveness. Both braid CF and MCF cables with 3,000 strands, 16 spindles, and braid density of 90% or over were adopted. The tape-type MCF specimens were spread into a tape(width: 15mm) using a hot melt to make a cable. The shield effectiveness was measured up to the 1GHz range in accordance with IEC 62153-4-6; braid shielded cables featured a superior shielding effect at 63dB than tape-type shielded cables. That was because the tape-type shielded cable has relatively more gaps and holes between carbon fibers than the braid type, resulting in a more inflow or emission of electromagnetic waves. In the case of braid cables, the characteristics of their electromagnetic waves were enhanced, with higher spindles and higher conductivity of carbon fibers. The shield effectiveness of the MCF shielded cable, however, was lower than that of tin-coated one.