• Title/Summary/Keyword: 저압 측정

Search Result 222, Processing Time 0.017 seconds

Comparison of Gas Exchange Parameters between Same Volume of $N_2-O_2$ and Heliox Inhalation (동일한 상시 호흡량의 $N_2-O_2$ 및 Heliox 투여 시 가스교환지표의 비교)

  • Sohn, Jang-Won;Lim, Chae-Man;Koh, Youn-Suck;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.169-175
    • /
    • 1998
  • Background: Heliox is known to decrease $PaCO_2$ in patients with increased airway resistance by increasing minute ventilation and reducing work of breathing(WOB). Besides these effect, heliox is expected to decrease functional anatomic dead space owing to improvement of peak expiratory flow rate(PEFR) and enhancement of gas distribution. We investigated whether heliox can decrease $PaCO_2$ even at the same minute ventilation (VE) and WOB with $N_2-O_2$ to speculate the effect of the heliox on the anatomic dead space. Material and Method: The subjects were 8 mechanically ventilated patients with asthma or upper airway obstruction(M : F=5 : 3, $68{\pm}10$years) who were under neuromuscular paralysis. The study was consisted of three 15-minutes phases: basal $N_2-O_2$ heliox and washout Heliox was administered via the low pressure inlet of servo 900C, and respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). To obtain the same tidal volume(Vt) in heliox phase, the Vt on monitor was adjusted by the factor of relative flow rate of heliox to $N_2-O_2$. Dead space was calculated by Bohr equation. Results: 1) Vt, VE, peak inspiratory pressure(PIP) and peak inspiratory flow rate(PIFR) were not different between $N_2-O_2$ and heliox. 2) PEFR was higher on heliox($0.52{\pm}0.19$L/sec) than $N_2-O_2$($0.44{\pm}0.13$L/sec)(p=0.024). 3) $PaCO_2$(mmHg) were decreased with heliox($56.1{\pm}14.1$) compared to $N_2-O_2$($60.5{\pm}15.9$)(p=0.027). 4) Dead space ventilation(%) were decreased with heliox($73{\pm}9$ with $N_2-O_2$ and $71{\pm}10$ with heliox)(p=0.026). Conclusion: Heliox decreased $PaCO_2$ even at the same VE and WOB with $N_2-O_2$, and the effect was considered to be related with the reduction of anatomic dead space.

  • PDF

Characteristics of Si Floating Gate Nonvolatile Memory Based on Schottky Barrier Tunneling Transistor (쇼트키 장벽 관통 트랜지스터 구조를 적용한 실리콘 나노점 부유 게이트 비휘발성 메모리 특성)

  • Son, Dae-Ho;Kim, Eun-Kyeom;Kim, Jeong-Ho;Lee, Kyung-Su;Yim, Tae-Kyung;An, Seung-Man;Won, Sung-Hwan;Sok, Jung-Hyun;Hong, Wan-Shick;Kim, Tae-You;Jang, Moon-Gyu;Park, Kyoung-Wan
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.302-309
    • /
    • 2009
  • We fabricated a Si nano floating gate memory with Schottky barrier tunneling transistor structure. The device was consisted of Schottky barriers of Er-silicide at source/drain and Si nanoclusters in the gate stack formed by LPCVD-digital gas feeding method. Transistor operations due to the Schottky barrier tunneling were observed under small gate bias < 2V. The nonvolatile memory properties were investigated by measuring the threshold voltage shift along the gate bias voltage and time. We obtained the 10/50 mseconds for write/erase times and the memory window of $\sim5V$ under ${\pm}20\;V$ write/erase voltages. However, the memory window decreased to 0.4V after 104seconds, which was attributed to the Er-related defects in the tunneling oxide layer. Good write/erase endurance was maintained until $10^3$ write/erase times. However, the threshold voltages moved upward, and the memory window became small after more write/erase operations. Defects in the LPCVD control oxide were discussed for the endurance results. The experimental results point to the possibility of a Si nano floating gate memory with Schottky barrier tunneling transistor structure for Si nanoscale nonvolatile memory device.