• Title/Summary/Keyword: 저시멘트콘크리트

Search Result 108, Processing Time 0.021 seconds

Properties of Low-heat Cement and Concrete (저발열 시멘트 및 콘크리트의 특성)

  • Noh, Jae-Ho;Park, Yon-Dong;Song, Yong-Soon;Kim, Hoon;Kang, Suck-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.345-351
    • /
    • 1996
  • The study on the properties of low-heat cement that hear of hydration is relatively lower than that of ordinary portland cement and concrete made of this low-hear cement has been performed to test the hear of hydration and compressive strength, chemical resistance of concrete using low-hear cement to compare with concrete using other several typers of cements.

  • PDF

An Experimental Study on the Evaluation of Hydration Heat of Low Heat Concrete (in case of Belite rich Cement) (저발열 콘크리트 수화열 평가의 실험적 연구 (Belite rich 시멘트 중심))

  • 현석훈;박춘근;신영인;김용호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.352-357
    • /
    • 1996
  • In hardening massive concrete, the heat of hydation gives rise to considerable thermal gradientsand thermal stresses, which might cause early age cracking. This paper deals with the results of evaluation of hydration heat of low hear concrete, using Belite rich cement (low heat cement) and compared with OPC, slag added cement and fly ash addedcement. Result of evaluation of hydration are presented in this paper. The concrete made with Belite rich cement gets low temperature of center point and low thermal gradients between surface and center points.

  • PDF

The Application of Super-flowing Concrete Using Low Heat Cement (저발연 시멘트를 사용한 초유동 콘크리트의 물성)

  • 노재호;한정호;송용순;최이현;천재원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.649-656
    • /
    • 1997
  • The properties of super-flowing concrete with low heat cement were experimentally investigated and compared with ordinary 25-240-15 concrete with type Vcement. The cement content of super-flowing concrete with the low heat cement was 400 kg/$\textrm{m}^3$. However the hydration heat of super-flowing concrete is relatively lower than that ordinary concrete with type V cement. Also the ability to resist chloride ion penetration of super-flowing concrete with low heat cement is 5 times better than that of the ordinary concrete.

  • PDF

A Study on Field Application of the Mass Concrete using Hydration Temperature-Reducing Binder - Focused on the Mock-up Test- (수화 온도 저감형 결합재를 이용한 매스콘크리트 현장적용에 관한 연구 -현장 Mock-up Test를 중심으로-)

  • Seo, Il;Kwon, Hae-Won;Park, Hee-Gon;Kim, Yoo-Jin;Kim, Woo-Jae;Lee, Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.371-372
    • /
    • 2010
  • This study was a result of mock-up test for the field application which was compared between low heat cement and temperature-reducing binder with the way of temperature crack reduction. The result of mock-up test was shown that the heat of hydration from the low heat cement and the temperature-reducing binder indicated 44 and $54^{\circ}C$ respectively.

  • PDF

Construction Performance of High Strength Concrete Utilizing Wasted Limestone Coarse Aggregates (석회암 폐석 굵은골재를 사용한 고강도 콘크리트의 시공)

  • Han, Cheon-Goo;Kim, Ki-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.6
    • /
    • pp.545-551
    • /
    • 2015
  • The aim of this research is suggesting application method of the wasted rock obtained from the limestone quarry of raw material for cement as a coarse aggregate for high strength concrete after crushing and sieving processes. The wasted rock has been normally wasted because of its low quality as a material for cement production. In this research, the concrete using this wasted limestone coarse aggregate was evaluated the constructability based on the performances of workability, air content, and compressive strength. From the experiment, a favorable performance was achieved with a limestone coarse aggregate for high strength concrete comparing to the high strength concrete using granite coarse aggregate.

Influence of Polycarboxylate type Superplasticizer on the Fluidity and Rate of Heat Liberation of Cement Paste (시멘트페이스트의 유동성 및 수화발열속도에 미치는 폴리카르본산계 고성능AE감수제의 영향)

  • Daiki, Atarashi;Song, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.813-816
    • /
    • 2008
  • Polycarboxylate-type superplasticizer is widely used for producing self-compacting and high-strength concrete and improving concrete durability. This paper discusses the influence of molecular structure of polycarboxylate-type superplasticizer on the fluidity and the rate of heat liberation of ordinary Portland cement paste. The fluidity of cement paste was increased by addition of polycarboxylate-type superplasticizer. The arrival time up to the maximum rate of heat liberation was increased by addition of polycarboxylate-type superplasticizer. The fluidity and the arrival time up to the maximum rate of heat liberation were more influenced by addition of polycarboxylate-type superplasticizer having shorter grafted chain than that having longer grafted chain.

  • PDF

Freeze-Thaw Resistance of Alkali Activated Ternary Blended Cement Incorporated with Ferronickel Slag (알칼리 활성화제를 첨가한 페로니켈슬래그 혼입 삼성분계 콘크리트의 동결융해 저항성)

  • Cho, Won-Jung;Park, Kwang-Pil;Ann, Ki-Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.2
    • /
    • pp.159-167
    • /
    • 2022
  • The present study assessed the micro structure and durability characteristics of ternary blended cement with different types of alkali activators. Ground granulated blast furnace slag(GGBS) and ferronickel slag(FNS) was replaced until 50 % of the weight of cement. In addition, potassuim hydroxide and sodium hydroxide were used for comparing the properties of different type of alkali activator. Ternary blended cement with alkali activators showed higher peak portlandite peak than that of OPC(Ordinary Portlande Cement) and non activated ternary blended cement. Also, there was no new hydration products in ternary blended cement or/and alkali activators. Based on the mercury intrustion porosimetry(MIP) test result, ternary blended cement increased macro pore while alkali activated ternary blended cement modified pore structure and increased microp pore as compared to OPC as control. Combination with alkali activators is desirable to enhance the compressive strength and freeze thaw resistance.

Selection of Portland Cement for Prevention of Sulfate Attack-Part 1 Sodium Sulfate Attack (황산염침식 방지를 위한 포틀랜드시멘트의 선정-Part 1 황산나트륨 침식)

  • Kim, Jong-Pil
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.441-447
    • /
    • 2009
  • This paper presents a detailed experimental study on the sulfate resistance of specimens made with portland cement exposed to sulfate attack. The mortar specimens were immersed in a 5% sodium sulfate solution for 360 days and regularly monitored for visual damage, compressive strength loss and expansion. In addition, at the end of 360 days, the products of sulfate attack and the mechanism of attack were investigated through X-ray diffraction, TG&DSC and scanning electron microscopy. The test results indicated that the sulfate deterioration data was ordinary portland cement > sulfate resistance portland cement > low heat portland cement. The microstructural studies indicated that the main reaction product of deterioration of the mortar specimens was the formation of ettringite, gypsum and thaumasite due to sulfate attack. For portland cement matrices, a low heat cement matrix containing the lowest C3A and silicate ratio (C/S) was beneficient against the sulfate attack.

A Evaluation of Manufactural Performance by Applied Quiet Pavement (저소음 포장의 현장 생산성능 평가)

  • Jun, Soon Je;Kim, Wan Sang;Kim, Young Jin;Ryu, Deug Hyun;Lee, Suck Hong
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.181-181
    • /
    • 2011
  • 도로는 국내 물류를 담당하는 중요한 기반시설로 국내 경제성장의 중추적인 역할을 담당하고 있다. 특히, 1970년대 개통된 경부고속도로는 우리나라의 대동맥으로 산업 성장의 파급효과를 가져오는 기반이 되었고, 공학적인 차원에서도 도로 포장재료를 경험 및 과학적으로 분석하여 적용하는 계기로 도로공학발전의 초석이 되었다. 과거에 적용된 도로 포장재료는 기술자의 경험에 의존하여 배합설계가 진행되었으며, 중차량의 비중이 많은 지역은 강성포장을 적용하고, 상대적으로 중차량이 적은 구간은 연성포장을 적용하는 설계를 따랐다. 하지만, 강성포장을 대표하는 시멘트 콘크리트 포장은 시공상의 복잡함과 시멘트 콘크리트 특성상 강도발현을 위해서 일정기간 이상의 양생일수가 필요하므로, 도로건설의 인프라 구축이 시급한 지역에서는 사용의 제약이 따른다. 연성포장을 대표적하는 재료로는 아스팔트 콘크리트 포장을 들 수 있다. 강성포장보다는 상대적으로 시공상의 편리함과 일정기간의 양생이 필요하지 않아 도로 포장재료로서 그 적용성이 우수하다. 과거에는 아스팔트 콘크리트 포장의 종류가 단순화되어 표층, 기층에 대표되는 몇몇 혼합물이 도로 포장재료로 사용되었다. 도로공학의 학문적 발달과 함께 도로포장의 전반적인 기술이 향상되고 있다. 과거의 도로 기능은 국가 경제발전을 위한 산업용 원자재의 운반이 주요 기능을 담당하고 있는 반면, 국민의 경제적 수준이 증대되고 자가용의 보급이 보편화되면서 도로 이용의 주체가 국민 개개인으로 변화되고 있고, 그 요구조건도 다양화되고 있다. 이에 발맞추어 도로공학의 기술적 향상으로 다양한 기능을 발휘할 수 있는 도로포장재료가 개발되고 있으며, 대표적인 제품으로는 배수성 포장, 반강성 포장, 보수성 포장, 탄성 포장, 저소음 포장 등이 있다. 본 연구에서는 기능성 포장의 하나인 저소음 포장의 특성 중 생산성능을 평가하였다. 생산성능이란 저소음포장을 현장 플랜트에서 생산하였을 경우의 특성을 분석하는 과정으로, 실내 실험으로 최적화된 재료의 배합은 이상적인 조건을 적용하여 결정된 것으로 입고된 현장 골재 및 생산 플랜트 조건에 따른 그 배합 및 물성이 변동을 가져올 수 있다. 특히, 저소음 포장은 기존의 아스팔트 포장과 달리 적용되는 골재, 아스팔트의 재료가 고성능을 발휘하기 위하여 특수한 재료를 적용해야 한다. 배합설계에서도 개립도 아스팔트 혼합물에 적용되는 내구성분석 절차를 따라야 하므로, 실내 배합설계 혼합물과 현장 생산 혼합물간의 물리적 특성에 차이를 나타낼 수 있다. 따라서, 본 연구에서는 실내 및 현장 혼합물의 전반적인 물리적 특성의 차이를 분석하여 저소음 포장의 현장 생산성능을 확인하였다. 분석요소로는 혼합물의 기초물성면에서는 밀도, 공극률을 분석하였으며, 실내 내구성면에서는 마샬안정도, 잔류안정도를 분석하여 실내 및 현장 혼합물의 물성차이를 분석하였다. 기초물성을 평가할 수 있는 밀도와 공극률에서는 생산 현장 혼합물이 실내 혼합물 보다 높은 밀도와 낮은 공극률을 나타내고 있으며, 이에 상관하여 강도특성을 분석할 수 있는 마샬안정도도 생산 현장 혼합물이 다소 높은 강도를 발휘하였다. 또한, 수분에 대한 안정성을 평가하는 인자인 잔류 안정도에서는 실내 및 현장 혼합물 모두 우수한 성능을 발휘하였다.

  • PDF

Fundamental characteristics of high early strength low heat concrete according to mineral binder and high early strength material combination (광물질 결합재 및 조강형 재료 조합에 따른 조강형 저발열 콘크리트의 기초적 특성)

  • Kim, Kyoungmin;Son, Hojung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2014
  • This study analyzed the fundamental characteristics of concrete according to a ternary system mixing in order to reduce hydration heat of mass concrete and to improve early age strength. The results are as follows. The fluidity of unconsolidated concrete satisfied the target scope regardless of the binder conditions. When the replacement ratio between FA and BS increased, the slump of low heat-A mix and low heat-B mix increased, and air content was not affected by the change of binders. As for setting time, low heat cement mix had the fastest regardless of W/B, and high early strength low heat mix achieved 6 hours' reduction compared with low heat-B mix at initial set, and 12 hours' reduction at the final set respectively. As for the simple hydration heat, the low mix peak temperature was the highest and low heat-B mix had the lowest temperature. And high early strength low heat mix was similar with that of low heat-B. The compressive strength of hardened concrete had similar strength scope in all mixes except for low heat-B mix at early ages, and had unexceptionally similar one without huge differences at long-term ages.