Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.

Verification of Dose Evaluation of Human Phantom using Geant4 Code (Geant4 코드를 사용한 인체팬텀 선량평가 검증)

  • Jang, Eun-Sung;Choi, Ji-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.529-535
    • /
    • 2020
  • Geant4 is compatible with the Windows operating system in C++ language use, enabling interface functions that link DICOM or software. It was simulated to address the basic structure of the simulation using Geant4/Gate code and to specifically verify the density composition and lung cancer process in the human phantom. It was visualized using the Gate Graphic System, i.e. openGL, Ray Tracer: Ray Tracing by Geant4 Tracing, and using Geant4/Gate code, lung cancer is modeled in the human phantom area in 3D, 4D to verify the simulation progress. Therefore, as a large number of new functions are added to the Gate Code, it is easy to implement accurate human structure and moving organs.

Effects of Ionizing Radiation on Sprout Inhibition and Nutritive Value of Potato Tubers (방사선(放射線) 조사(照射)가 감자 괴경(塊莖)의 맹아억제(萌芽抑制) 및 영양가(營養價)에 미치는 영향(影響))

  • Lee, Mie-Soon;Kim, Hong-Lyour
    • Korean Journal of Food Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.29-35
    • /
    • 1972
  • Effects of various dosages of gamma ray ranging from 0 to 16 krad on sprout inhibition and nutritive value of potato tubers were investigated with Irish Cobbler variety. Sprout growth was gradually suppressed with increasing dosage, and completely inhibited with 16 krad treatment. Under this optimum dosage, weight loss of tubers was markedly reduced and tubers kept firm throughout the 2 month storage period. Irradiation had no adverse effects on the cooking quality of potato tubers. Moisture content of stored potato tubers was shown to be in inverse proportion to sprout growth. Tubers treated with 16 krad tended to contain somewhat higher percentage of total carbohydrate than those treated with lower dosages. Significantly larger amounts of ascorbic acid were retained in 8 and 16 krad treatments than in 0 and 2 krad treatments.

  • PDF

Effect of Irradiation Time after Harvesting and Irradiation Dose on its Storability of Potatoes (감자 수확후(收穫後) 방사선(放射線) 조사시기(照射時期) 및 조사선량(照射線量)이 그 저장성(貯藏性)에 미치는 영향(影響))

  • Cho, Han-Ok;Byun, Myung-Woo;Kwon, Joong-Ho;Yang, Ho-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.11 no.4
    • /
    • pp.53-59
    • /
    • 1982
  • In order to determine the optimun condition for the long term storage of potatoes by irradiation combined with natural low temperature, the dose range and irradiation time after harvesting of two varieties were investigated. Although optimum dose of potatoes and was different according to the variety 12.5krad seemed optimum untill 15-30 day after harvesting and 15krad was for later than 45 day after harvesting. The sooner the irradiation was efficient after harvesting. Optimum dose irradiated group were better in change of sprouting, rotting, weightloss and shrivelling and was extended the storage period more than four months compared with control at natural low temperature storage room.

  • PDF

Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation (필름을 사용한 세기변조치료법에 대한 선량측정)

  • Ju Sang Gyu;Yeo Inhwan Jason;Huh Seung Jae;Choi Byung Ki;Park Young Hwan;Ahn Yong Chan;Kim Dae Yong;Kong Young Kun
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.172-178
    • /
    • 2002
  • Purpose : X-ray film over responds to low-energy photons in relative photon beam dosimetry because its sensor is based on silver bromide crystals, which are high-Z molecules. This over-response becomes a significant problem in clinical photon beam dosimetry particularly in regions outside the penumbra. In intensity modulated radiation therapy (IMRT), the radiation field is characterized by multiple small fields and their outside-penumbra regions. Therefore, in order to use film dosimetry for IMRT, the nature the source of the over-response in its radiation field need to be known. This study is aimed to verify and possibly improve film dosimetry for IMRT. Materials and Method : Modulated beams were constructed by a combination of five or seven different static radiation fields using 6 MeV X-rays. In order to verify film dosimetry, we used X-ray film and an ion chamber were used to measure the dose profiles at various depths in a phantom. In addition, in order to reduce the over-response, 0.01 inch thick lead filters were placed on both sides of the film. Results : The measured dose profiles showed a film over-response at the outside-penumbra and low dose regions. The error increased with depths and approached 15% at a maximum for the field size of $15{\times}15cm^2$ at 10 cm depth. The use of filters reduced the error to 3%, but caused an under-response of the dose in a perpendicular set-up. Conclusion : This study demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy Photons. The use of filers can enhance the accuracy in film dosimetry for IMRT. In this regard, the use of optimal filter conditions is recommended.

Fabrication and characteristics of Hybrid-type radiation detector using $HgI_2$ (혼합형 구조를 적용한 $HgI_2$ 기반의 방사선 센서 제작 및 특성)

  • Jang, K.Y.;Kang, H.G.;Lee, G.H.;Kim, S.Y.;Park, J.K.;Choi, H.K.;Nam, S.H.;Lim, J.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.460-463
    • /
    • 2004
  • 본 논문은 고에너지 방사선 검출을 위한 흔합형 구조의 방사선 센서를 제작, 반응 특성을 평가하였다. 먼저, 스크린 인쇄법을 이용하여 형광체 필름을 제작하였으며, 발광스펙트럼(PL, Photoluminescence) 및 잔광 시간(decay time) 측정을 통하여 형광체의 발광 특성을 조사하였다. 제작된 혼합구조의 방사선 센서는 $2{\mu}m$ 두께의 $HgI_2$$150{\mu}m$ 두께의 형광체 필름으로 제작되었으며, 면적은 $2\;cm\;{\times}\;2\;cm$이다. 방사선에 대한 전기적 검출 신호의 특성을 조사하기 위해 인가전압에 따른 암전류 및 방사선민감도, 선량에 따른 검출신호를 측정하였다. 측정결과, 제작된 $HgI_2$ 필름은 방사선에 의해 형광체에서 방출된 가시광 파장을 잘 흡수하였으며, 진단영역의 저에너지 방사선에 의해 직접 전기적 신호를 발생시켜 높은 방사선 민감도를 보였다. 뿐만 아니라, 인가전압에 대해 $10\;pA/mm^2$이하의 낮은 암전류를 가졌으며, 넓은 조사선량에서 우수한 선형성을 보였다.

  • PDF

Study on The Technical Improvement in Wireless Power Communication System with Low Power (무선전력통신 시스템의 저전력화를 위한 기술적 개선방안)

  • Chung, Sung-In;Lee, Seung-Min;Lee, Hyo-Sung;Lee, Hug-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.53-57
    • /
    • 2010
  • This study proposes the algorithm which drives the powerless without battery. The exiting wire or RF type dosimeter, which is the computation of the real time with battery on the dose radiation exposure, In the Wired dosimeter, it is trouble to need the maintenance and management by periods. Besides, the case of the RF typed dosimeter with battery, it is requested to size bigger and to replace battery frequently and so on. Especially RF typed dosimeter has trouble to need for the embody with large power consumption on the contactless typed dosimeter. As the method for the low power, the study designed to be down the operating clock of the MPC, to improve the efficiency of the rectifier, to eliminate the external memory and the DC-DC converter for the simplification of the circuit We convince our research contributes not only to understand the simplified circuit and miniaturization, but also to help the design and application technology of the powerless dosimeter.

Radioresistance of Acorus calamus to Gamma Ray Irradiation

  • Lee, Ja-Hyun;Kang, Si-Yong;Lee, Geung-Joo;Lee, Seong-Gene;Kim, Sun-Kook;Han, Tae-Ho
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.2
    • /
    • pp.119-125
    • /
    • 2011
  • Acorus calamus is an indigenous hydrophyte used as phytoremediation and water purification as well as medicinal herb. Irradiation of gamma ray was performed to investigate the effect on radioresistance of A. calamus on in vitro. Various doses (20-500 Gy) of gamma rays were irradiated to in vitro plantlets. The effect of irradiation was studied on survival rate, shoot formation and growth rate. The survival and multiplication rate was remarkably decreased with the increase of radiation dose. The growth of plantlets was significantly increased in comparison to the control at low doses. The hermetic effect of radiation was appeared in A. calamus. It was significantly decreased or interrupted above 250 Gy. The mean 50% lethal dose ($LD_{50}$) was extremely high as 240 Gy. We conclude that A. calamus had remarkably high radioresistance compared with other plant species.

A STUDY OF THE LOW LEVEL RADIATION EFFECT ON THE MITOTIC INDEX OF THE BASAL CELLS IN THE BUCCAL POUCH OF HAMSTERS (저선량방사선이 햄스터의 협낭 기저세포 분열지수에 미치는 영향에 관한 연구)

  • Kang Byung-Cheol;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.215-226
    • /
    • 1993
  • The purpose of this study was to investigate the effects of the low level irradiation on the mitotic index of the basal cells in the buccal pouch of hamsters{golden hamster: APG strain). After colchicine was administrated to the hamsters through the intraperitoneal, the low level radiation{5460mR) was exposed on the buccal pouch of hamsters. The mitotic index of the basal cells was estimated 2 hours after irradiation. The results were as follows: 1. The mean mitotic index of the control group was 4.32. 2. The mean mitotic index of the irradiated group was 2.46. 3. T-test of data in the irradiated group showed significant difference from the mitotic index in the control group. These results suggested the lowered mitotic index of the irradiated group resulted from the low level irradiation.

  • PDF

The Effect of Low Dose Radiation on the Neuronal Cell Proliferation in Diabetic Rats (당뇨병 유발 쥐에서 신경 세포 증식에 대한 저선량 방사선의 효과)

  • Kim Doo Soon;Kang Jin Oh;Hong Seong Eon;Kim Sang Ki;Lee Taeck-Hyun;Kim Chang-Ju
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.157-160
    • /
    • 2005
  • Purpose: To investigate the effect of low dose radiation on neuronal cell proliferation In diabetic rats. Materials and Methods: A group of rats (first group) were divided into three subgroups (nondiabetic control, nondiabetic 0.1 Gy and nondiabetic 10 Gy groups) to determine the effect of radiation on normal hippocampal neuronal ceil proliferation. A further group of rats (second group) were divided into six subgroups (nondiabetic control, diabetic control, diabetic 0.01 Gy, diabetic 0.1 Gy, diabetic 1 Gy and diabetic 10 Gy groups) to determine the effect of radiation on hippocampal neuronal cell proliferation under diabetic conditions. Using immuno-histochemistry for 5-bromo-2'-deoxyuridine (BrdU), the number of neuronal cells in the dentate gyrus of all the groups was counted. Results: The number of BrdU-positive cells in the dentate Gyrus of the nondiabetic control, nondiabetic 0.1 Gy and nondiabetic 10 Gy subgroups of the first group were $45.95{\pm}3.42,\;59.34{\pm}5.20\;and\;19.26{\pm}2.98/mm^2$, respectively. The number of BrdU-positive cells in the dentate gyrus of the diabetic control, diabetic 0.01 Gy, diabetic 0,1 Gy, diabetic 1 Gy and diabetic 10 Gy subgroups of the second group were $55.44{\pm}8.57,\;33.33{\pm}6.46,\;67.75{\pm}10.54,\;66.63{\pm}10.05,\;23.59{\pm}6.37\;and\;14.34{\pm}7.22/mm^2$, respectively. Conclusion: Low dose radiation enhances cell proliferation in the dentate gyrus of STZ-induced diabetic rats.