• Title/Summary/Keyword: 저선량방사선

Search Result 373, Processing Time 0.029 seconds

The Radiation Dose and The Relationship between Proof Alcohol Takju Preliminary Research (방사선 조사선량과 탁주 알콜도수와의 상관관계 사전조사)

  • Kim, Seon-Chil;Cho, Young-Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.197-200
    • /
    • 2012
  • This research investigated Takju alcohol content in the case of irradiation changes in the statistical analysis was performed to visually. Lower proof alcohol fermentation Takju traditional and largely maintained 6 degrees, from the heat sterilization process is controlled through the distribution period. Most of the existing irradiation is focused on preservation of the product, but this study of the quality characteristics of the mechanical changes in alcohol was to seek value. Takju Celsius to $15^{\circ}C$, while maintaining the experiment were kept in the state. Radiation devices Varian Clinac ix, 2010 (Max. 10MV) using the field size $150mm{\times}150mm$, SSD 100 cm at 40kVp 1, 4, 7, 10, 13, 15, 20Gy were vertical. KJELDAHL APPARATUS, C-H6 Alcohol frequency was measured using. The results according to the change of the radiation dose alcohol did not show the sudden change of frequency, were observed at similar levels decreased. This study simply due to the radiation dose to be served, but to find the change in the future with a greater sense of quality changes should be considered.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

Optimization of Non-Local Means Algorithm in Low-Dose Computed Tomographic Image Based on Noise Level and Similarity Evaluations (노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화)

  • Ha-Seon Jeong;Ie-Jun Kim;Su-Bin Park;Suyeon Park;Yunji Oh;Woo-Seok Lee;Kang-Hyeon Seo;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.39-48
    • /
    • 2024
  • In this study, we optimized the FNLM algorithm through a simulation study and applied it to a phantom scanned by low-dose CT to evaluate whether the FNLM algorithm can be used to obtain improved image quality images. We optimized the FNLM algorithm with MASH phantom and FASH phantom, which the algorithm was applied with MATLAB, increasing the smoothing factor from 0.01 to 0.05 with increments of 0.001 and measuring COV, RMSE, and PSNR values of the phantoms. For both phantom, COV and RMSE decreased, and PSNR increased as the smoothing factor increased. Based on the above results, we optimized a smoothing factor value of 0.043 for the FNLM algorithm. Then we applied the optimized FNLM algorithm to low dose lung CT and lung CT under normal conditions. In both images, the COV decreased by 55.33 times and 5.08 times respectively, and we confirmed that the quality of the image of low dose CT applying the optimized FNLM algorithm was 5.08 times better than the image of lung CT under normal conditions. In conclusion, we found that the smoothing factor of 0.043 among the factors of the FNLM algorithm showed the best results and validated the performance by reducing the noise in the low-quality CT images due to low dose with the optimized FNLM algorithm.

A Cohort Study on Cancer Risk by Low-Dose Radiation Exposure among Radiation Workers of Nuclear Power Plants in Korea (저준위 방사선 노출의 암 유발에 관한 국내 원전종사자 코호트 연구)

  • Lim, Young-Khi;Yoo, Keun-Young
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.2
    • /
    • pp.53-63
    • /
    • 2006
  • The increased risk of cancer with exposure to low-dose radiation was estimated through longitudinal study for radiation workers at the nuclear power plants in Korea. The radiation dose data were collected from the Radiation Safety Management System(RSMS) of the Korea Hydro & Nuclear Power Co., Ltd(KHNP). The cancer risks with radiation exposure were evaluated in terms of relative mortality ratios(RMR) and relative incidence ratios(RIR) to the unexposed employees at the nuclear power plants, and of the standardized mortality ratios(SMR) and standardized incidence ratios(SIR). There were no significant increases of canters of all sites in the exposed group either in RIR[1.08, 95% confidence interval(CI) 0.74-1.58] or in RMR[1.21, CI 0.70-2.08]. Neither SIR[0.81, CI 0.28-0.96] nor SMR[0.86, CI 0.66-1.10] significantly deviated from 1.0 for cancers of all sites. The trend analysis did not identify evident dose-response relationship due to insufficient numbers of the cases. Consequently, it is concluded that increases in cancer risks in the radiation worker group exposed to low doses at the nuclear power plants in Korea are not identified at this time.

Decrease of Irradiated Volume using Rotational Treatment by Avoidance Sector in Radiation Therapy for Esophageal Cancer (식도암의 방사선치료에서 부분 각도에 의한 회전 치료를 이용한 조사체적의 감소)

  • Hwang, Chulhwan;Kim, Seong Hu;Koo, Jae Heung;Son, Jong Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.583-592
    • /
    • 2018
  • In this study, plans to apply 3D conformal radiotherapy, intensity modulated radiotherapy, and volumetric intensity modulated arc radiotherapy to esophageal cancer radiotherapy were compared. In particular, arc therapy was applied to reduce irradiated volume and spread of low-dose during intensity modulated radiation therapy and volumetric intensity modulated arc radiotherapy by limiting part of irradiated angle, in order to compare target doses and dose for surrounding normal tissues of the two methods and those of 3D conformal radiotherapy. No significant difference in target dose was found among the three methods. The 5 Gy volume(V5) of the lung showed 56.53% of conformal radiotherapy, 52.03% of intensity modulated radiotherapy, and 47.84% of volumetric modulated arc therapy(CRT-IMRT p=0.035, CRT-VMAT p<0.001, IMRT-VMAT p<0.001). The 10 Gy volume(V10) showed a significant difference in conformal radiotherapy 35.12%, intensity modulated radiotherapy 34.04%, and volumetric modulated arc radiotherapy 33.28%, showing significant difference in intensity modulated radiotherapy(p=0.018), volumetric modulated arc therapy(p=0.035), no significant difference in dose was found at 20 Gy volume. The mean dose and 20 Gy volume of the heart were not significantly different according to the treatment plan, but the 30 and 40 Gy volumes were 37.16% and 22.46% in the volumetric modulated arc radiotherapy, showing significant differences(p=0.028) in comparison with conformal radiotherapy. It is believed that, by limiting part of the irradiated angle during intensity modulated radiotherapy and volumetric intensity modulated arc radiotherapy, the irradiated volume and, thereby, the 5-10 Gy area and toxicity of the lung can be reduced while maintaining dose distribution of the target dose.

The apoptotic fragment assay in rat peripheral lymphocytes and crypt cells with whole body irradiation with 60Co ϒ-rays and 50 MeV cyclotron fast neutrons (코발트-60 감마선과 50 MeV 싸이크로트론 고속 중성자선에 전신조사된 랫드의 말초 임파구와 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구)

  • Kim, Tae-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.2
    • /
    • pp.203-210
    • /
    • 2001
  • Here, we compared the effectiveness of 50 MeV($p{\to}RBe^+$) cyclotron fast neutrons versus $^{60}Co$ ${\gamma}$-rays by the apoptotic fragment frequency in both rat peripheral lymphocytes and crypt cells to check a radiobiological endpoint. The incidence of apoptotic cell death was increased in all irradiated groups, and radiation at all doses trigger rapid changes in both crypt cells and peripheral lymphocytes. These data suggest that apoptosis may play an important role in homeostasis of damaged radiosensitive target organ by removing damaged cells. The curve of dose-effect relationship for these data of apoptotic fragments frequencies was $y=0.3+(6.512{\pm}0.279)D(r^2=0.975)$ after neutrons, while $y=0.3+(4.435{\pm}0.473)D+(-1.300{\pm}0.551)D^2(r^2=0.988)$ after ${\gamma}$-rays. In addition, $y=3.5+(118.410{\pm}10.325)D+(-33.548{\pm}12.023)D^2(r^2=0.992)$ after ${\gamma}$-rays in rat lymphocytes. A significant dose-response relationship was found between the frequency of apoptotic cell and dose. These data show a trend towards increase of the numbers of apoptotic cells with increasing dose. Dose-response curves for high and low linear energy transfer (LET) radiation modalities in these studies were different. The relative biological effectiveness (RBE) value for crypt cells was 1.919. In addition, there were significant peaks on apoptosis induction at 4 and 6h after irradiation, and the morphological findings of the irradiated groups were typical apoptotic fragments in crypt cells that were hardly observed in the control group. Thus, apoptosis induction in both crypt cells and peripheral lymphocytes could be a useful endpoint of rat model for studying screening test and microdosimetic indicator to evaluate the biological effects of radiation-induced cell damage.

  • PDF

Treatment Results of Esophageal Carcinoma Treated by Radiation Therapy (식도암의 방사선치료 성적)

  • Kim Mi Sook;Yoo Seoung Yul;Cho Chul Koo;Yoo Hyung Jun;Yang Kwang Mo;Kang Jin Oh;Ji Young Hoon;Lee Dong Han;Ryoo Baek Yeol
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.182-186
    • /
    • 2000
  • Purpose : To determine treatment or이ecol for inoperable esophageal cancer patients, 껜e evaluated survival rate and prognostic factors. Materials and Methods : We evaluated esophageal cancer treated by curative or palliative am in KCCH from 1992 to 1996, retrospectively. Recurrent or underdose case below 40 Gy were excluded. The number of male and female were 35 and 5, respectively. Thirty-eight patients were squamous carcinoma and 2 patients were not biopsy proven. Ten patients were treated with radiation therapy and chemotherapy Median dose of radiation therapy was 59.4 Gy and the range was $40\~60$ Gy. Results : The median survival is 6.5 months and 1-year survival rate was $28.3\%$. Age, location, radiation dose and chemotherapy were not significant prognostic factors. Median survivals of patients with below stage III and over stage IVA were 7.6 and 6.2 months respectively, but it is not significant. Conclusions : The survival for esophageal cancer is very poor. For patients with curative aim, chemotherapy must be considered. For patients with palliative aim, short-term external beam radiation therapy and/or brachytherapy must be considered.

  • PDF

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

Dose Distribution of 3-Channel Ovoid Applicator (3-Channel Vaginal Ovoids의 선량분포 특성)

  • Kim Chang Hee;Yun Sang Mo;Kim Sung Kyu;Shin Sei One
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.134-139
    • /
    • 2004
  • This study was aimed to develop a new ovoid applicator for vaginal high-dose rate intracavitary radiation therapy, evaluate uniformity of dose distribution, and assess clinical applicability. The authors evaluated dose uniformity of vaginal mucosa according to 5-different ovoid-separation using 2-channel and modified 3-channel ovoid applicator. There were no significant differences in the dose distribution along the vaginal mucosa with 2 and 2.5 cm separations, but there were between the 2-channel and 3-channel ovoid applicator with a separation of 3 cm or more. Although a low dose area was shown between two ovoid applicators with the 2-channel ovoid applicator, the dose distribution along the vaginal mucosa with the 3-channel ovoid applicator was very uniform.

  • PDF

Irradiation Preservation of Korean Shellfish (방사선(放射線) 조사(照射)에 의한 한국산(韓國産) 패류(貝類)의 품질보존(品質保存)에 관(關)한 연구(硏究))

  • Chung, Jong-Rak;Kim, Su-Il;Lee, Min-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.147-160
    • /
    • 1976
  • Pacific oyster, hard clam and mussel were irradiated at doses up to 0.5 Mrad, the optimum dose rather than the maximum permissible was sought for in each species and post-irradiation storage characteristics studied at $0^{\circ}\;and\;5^{\circ}C$. No shellfish meat irradited at doses as high as 0.5 Mrad produced any adverse odor. However the organoleptic quality of each sample irradiated at lower doses was superior to those irradiated at the higher during the early storage period. The optimum dose was determined to be 0.2 Mrad for Pacific oyster and mussel and 0.1 Mrad for hard clam. By irradiating at the optimum dose, the storage life of Pacific oyster cculd be extend from less than 14 days to 35 days at $0^{\circ}C$ and from only 3 days to 21 days at $5^{\circ}C$. A similar storage extension was observed with mussel. The storage life of hard clam was extended from 7 days to 14 days at $0^{\circ}C$ and from 3 days to 12 days at $5^{\circ}C$. The hard clam meats were particularly susceptible to tissue softening by irradiation; an earlier onset and more extensive softening were observed with increasing dose.

  • PDF