• Title/Summary/Keyword: 저농도 오수

Search Result 8, Processing Time 0.026 seconds

Design and Operation of the Rainwater-Greywater Hybrid System : SNU No. 39 Building (빗물-저농도 오수 하이브리드 시스템의 설계 및 운전 평가 : 서울대 39동)

  • Shim, In-tae;Park, Hyun-ju;Kim, Tschung-il;Jung, Sung-un;Han, Moo-young;Namkung, Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.676-682
    • /
    • 2016
  • In this study, rainwater-greywater hybrid system was installed and operated for 1 year in order to evaluate its water quantity, water quality, and economic efficiency in building no. 39. This system was expected to overcome each disadvantages of and maximize each advantages. Low-greywater that was washed up from shower room was treated by MBR (Membrane Bioreactor) and ozone oxidation. Rainwater that was collected from the rooftop was stored in a reservoir, and then transferred to the storage tank that was mixed with treated greywater. After 1 year operating in building no. 39, rainwater and greywater was used to supply $2,599m^3$ of toilet flushing water. In terms of water quality, rainwater was satisfied far the greywater reuse standards except for E.coli. Moreover, low greywater quality was acceptable except for E. coli, BOD, SS, and turbidity. In addition, economic analysis was obtained from benefit-cost ratio (B/C) with 1.11. It implies that the feasibility of the project was reasonable. Furthermore, various research and policy to improve the economic efficiency of water recycling facilities is required to expand the use of water recycling facilities.

Effects of Detention Time and Disc Speed on the Treatment Efficiencies of RBC (체류시간(滯留時間)과 원판회전속도(圓板回轉速度)가 회전원판생물막법(回轉圓板生物膜法)의 처리효율(處理効率)에 미치는 영향(影響))

  • Kim, Sang Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.3
    • /
    • pp.1-9
    • /
    • 1984
  • A mult-stage rotating biological contactor process was evaluated by using the mixtures of nightsoil and sewage as influent substrate. An emphasis was concentrated on the BOD removal efficiency at each stage of the process with respect to hydraulic detention times, rotating speeds of the disc and influent organic substrate concentrations. The results indicated that the process was found to be economically feasible when operated at hyduraulic detention time of 2 hours and disc rotating speed of 3 RPH. As to treatment efficiency, BOD removal efficiency of 40 to 50 percent could be obtained at the first stage regardless of influent organic substrate concentrations. The overall BOD removal efficiency of the process was found to be 88 to 90 percent at even high organic loading of $2.0kgBOD/m^3{\cdot}day$.

  • PDF

Fouling Control Technique of Membrane Using Simultaneously Washing Process (동시세정방식을 이용한 막의 fouling 억제기술)

  • Choi, I-Song;Son, Chang-Sun;Kim, Sung-Yoon;Lim, Byung-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1637-1641
    • /
    • 2009
  • 본 연구는 막공정을 이용하는 수처리기술에 있어서 최대 난점 중의 하나인 fouling 현상을 억제하기 위하여 여과방향의 반대방향에서 여과수를 지속적으로 분사하여 줌으로써 여과와 세정이 동시에 일어나는 동시세정방식을 평가하기 위한 것이다. 실험은 성균관대학교 환경플랜트 내에 pilot 실험지를 조성하여 실시하였으며, 실험원수는 오수처리방류수를 저류하는 연못수와 오수원수를 혼합하여 농도를 조절한 후에 저농도와 고농도 조건에서 실험을 실시하였다. 저농도 조건(SS 10$\sim$20 mg/L)에서는 연못의 HRT를 고려하여 일일 5시간 씩 8일간 가동하였고, 고농도 조건(SS 200 mg/L 이상)에서는 8시간씩 가동하였다. 저농도의 경우에는 가동기간 중 배수가 일어나지 않았고, 일일 운전 종료 후 유지관리를 위한 강제배수만 실시하였다. 고농도에서는 초기에 배수가 짧은 term으로 자주 일어났지만, 20분 이상의 비교적 긴 여과지속시간을 유지하였고 유입수 농도가 낮아지면서 배수타임이 점점 늘어나는 경향을 보였다. 이러한 결과는 동시세정방식에 의한 여과기술에 있어 유입수 농도가 fouling 발생빈도에 크게 영향을 미친다는 것을 의미하며, $5\;{\mu}m$의 미세막에서도 고농도 운전이 가능하다는 사실을 보여준다. 동시세정방식은 Rum Filter의 fouling을 억제하고 지속적인 운전을 가능하게 해주는 핵심기술이다. 세정 시 세정압력설정은 매우 중요한 운전인자 중 하나인데, 세정압력이 너무 클 경우에는 소요되는 동력이 많아져 효율적인 설계 및 운전에 장애요인이 될 수 있고, 너무 낮을 경우에는 세정이 제대로 되지 않고 여과막 내부와 외부의 압력차를 크게 가져와 배수타임이 빨라지는 결과를 초래한다. 따라서 적절한 세정압력을 파악하고 설정하기 위하여 세정압력을 변화시켜가면서 이에 따른 차압의 변화를 관측하여 보았다. 여과막의 공극과 세정압력에 변화를 주면서 실험을 한 결과, 세정압력이 커지면 여과막에 작용하는 부하가 약간 증가하는 것으로 나타났지만, 그 차이가 $0.02\;kg_f/cm^2$으로 나타나, $4.0\;kg_f/cm^2$ 이상의 세정압력에서 적용이 가능한 것으로 나타났다. 또한, 유입유량을 설정하기 위하여 $4.5\;kg_f/cm^2$의 세정압력을 유지한 상태로 유입유량을 점진적으로 증가시키면서 압력의 변화를 관측하였다. $5\;{\mu}m$에서는 180 LPM 및 200 LPM에서, $8\;{\mu}m$에서는 200 LPM에서 자체적으로 설정한 배수차압 상승분인 $0.1\;kg_f/cm^2$를 초과한 것으로 나타났고, $10\;{\mu}m$ 이상에서는 모두 200 LPM이상 처리해도 배수압력에 걸리지 않는 것으로 나타났다. 이러한 결과는 현재 본 시스템에 적용하고 있는 유입유량 기준치를 2배 이상 상회하는 결과로서 추가적인 실험을 통하여 기존 여과기술보다 여과지속시간이길고, 여과 flux가 높은 기술을 개발할 수 있을 것으로 판단된다.

  • PDF

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

The Effect of Reclaimed Sewage Irrigation on the Rice Cultivation (벼 재배시 생활오수 처리수 관개 효과)

  • Yoon, Chun-Gyeong;Kwun, Soon-Kuk;Chung, Ill-Min;Kwon, Tae-Young
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.3
    • /
    • pp.236-244
    • /
    • 1999
  • A feasibility study was performed to examine the agronomic application of treated sewage on paddy rice culture by field experiment. The domestic sewage was treated by the constructed wetland system which was in subsurface flow type and consisted of sand and macrophyte. The effluent of the wetland system was adjusted to maintain the total nitrogen concentration below $25mgL^{-1}$ and used for irrigation water. Four treatments include (1) irrigation of treated sewage after concentration adjusted with conventional fertilization (TWCF), (2) irrigation of treated sewage after concentration adjusted with half of the conventional fertilization (TWHF), (3) irrigation of treated sewage after concentration adjusted without fertilization (TWNF), and (4) irrigation of treated sewage as it was without fertilization (SWNF). These cases were compared to the control case of tap water irrigation with conventional fertilization (Control). Generally, addition of the treated sewage to the irrigation water showed no adverse affect on paddy rice culture, and even improvement was noticed in both growth and yields. TWCF showed the best result and the yields exceed the Control in about 10%. Overall performance of the treatments was TWCF, Control, TWHF, TWNF, and SWNF in decreasing order. From this study, it appears that reuse of treated sewage as a supplemental irrigation water could be feasible and practical alternative for ultimate sewage disposal which often causes water quality problem to the receiving water body. For full scale application, further study is recommended on the specific guidelines of major water quality components and public health.

  • PDF

Adsorption and Degradation of Alkylbenzenesulfonate by Soils (Alkylbenzenesulfonate의 토양(土壤)에 의한 흡착(吸着)과 분해(分解))

  • Ha, Sang-Keon;Joo, Jin-Ho;Um, Myung-Ho;Lim, Hyung-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.2
    • /
    • pp.169-175
    • /
    • 1988
  • A laboratory experiment was conducted to investigate the effects of pH, organic matters and anion on the adsorption and degradation of surfactant by different soils; Anmi series (limestone region), Gangseo series (alluvial soil). For this study, Alkyl Benzene Sulfonate (ABS ; Sodium Dodecylbenzenesulfonate) was used as a surfactant. The results were as follows: 1. Adsorption of ABS by soils was correlated positively with the equilibrium concentration of ABS in a soil suspension. (Anmi seris : r=0.9855, Gangseo series : r=0.9931). 2. Adsorption rate of ABS by soils was about 70% of the treated concentration ($600{\mu}g$ ABS/g soil) in a range of pH 4 to pH 5, and about 20% for pH 8. 3. Addition of electrolytes increased ABS adsorption by soils in a soil suspension; the higher concentration, the higher adsorption. But the influence among electrolytes was not significant. 4. Adsorption of ABS by soils was not affected by soil organic matter content in this experiment. 5. Degradation rate of ABS in a soil suspension was about 85% at $30^{\circ}C$, and about 10 to 15% at $10^{\circ}C$. Addition of sewage accelerated the degradation rate regardless of temperature and reached about 85% in a week.

  • PDF

Treatment of Animal Wastewater Using Woodchip Trickling Filter System and Physical and Microbial Characteristics of Wood Chip Media (목편살수여상조를 이용한 축산뇨오수 처리와 목편여재의 물성 및 부착미생물 특성)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.71-80
    • /
    • 2011
  • Trickling filter has been extensively studied for the domestic wastewater treatment especially for the small scale plants in rural area. The purpose of this research is to survey the physical and microbial characteristics of wood chip media and the removal efficiency of animal wastewater using wood chip trickling filter system. The trickling filtration system comprises a filtration bed packed with wood chip media having a particle dia. of 5~7cm. The method comprises natural air from the bottom of the bed. The system also comprises a control mechanism including a time a constant discharge pump for controlling supply of the wastewater into the bed. The following conclusions were obtained from the results of this research. 1. The specific surface area of wood chip was 0.4123 $m^2$/g, pore volume was 0.0947 $cm^3$/g, density was 0.49 g/$cm^3$. It has forms of parallelogram and oblong which have numerous small pore space. This wood chip has been good condition for microorganism's habitat, having very larger specific surface area by complex the three dimension structure of cellulose at wood's major ingredients. 2. The total counts of in attached aerobic microbes were ranged from $10^6$ to $10^8$ CFU/g, and anaerobes microbial numbers were from $10^4$ to $10^7$. The aerobic microbial numbers appeared to be much more than those of anaerobic microbial numbers. 3. The average efficiency of $BOD_5$ and CODcr were 74.5% and 51.5%, respectively. The removal efficiency of T-N and T-P were 61.4%, 56.2%, respectively. But SS removal levels remain 19.3%.

Smart Manhole Device for Underground Facility Management (지중 시설물 관리를 위한 스마트 맨홀 디바이스)

  • Kim, Jong-Duk;Han, Seung-Heon;Kim, Yong-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.996-1003
    • /
    • 2019
  • The undergrounding of diverse ground facilities has led to a decrease in issues, such as foul smell of water supply systems and wastewater, a fall of telephone poles, electromagnetic waves and breaking of wires caused by a railway work. On the other hand, there are new issues, including a fall accident, explosion affected by flammable gas, a choking accident by harmful gas and a lack of oxygen concentration, a fire coming from high-tension wire heating and flooding in the manhole. Besides, these issues damage the civil society and are an anxiety to public safety. Therefore, this paper is focused on a smart manhole device for stable communication environments inside and outside the manhole and wireless communication with various devices for managing facilities in the manhole, and aims to make a contribution to public safety by suggesting a direction of future underground facility management.