• Title/Summary/Keyword: 재 부착파

Search Result 34, Processing Time 0.025 seconds

Treatment of crown-root fracture with a modified crown fragment reattachment technique (변형된 치관부 파절편 재부착술식을 이용한 치관치근파절의 치료)

  • Song, Chang-Won;Song, Min-Ju;Shin, Su-Jung;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • The development of adhesive dentistry has allowed that the crown fragment reattachment can be another option in the treatment of crown fracture. However, additional crown lengthening procedure or extrusion of the tooth may be necessary in the treatment of crown root fracture because subgingival fracture line in close proximity to the alveolar bone leads to challenges for restorative procedure and the violation of the biologic width. This case report presents a modified crown fragment reattachment technique of crown root fracture with pulp exposure, which was done without additional crown lengthening procedures. After the endodontic treatment, the patient was treated using a post insertion and the fragment reattachment technique, which made it possible to preserve the space for the biologic width and maintain a dry surgical field for adequate adhesion through the modification of the fractured coronal fragment. Since a coronal fracture was occurred and reattached afterward, it was observed that the coronal fragment was well maintained without the additional loss of periodontal attachment through 2-year follow up.

Fracture Resistance of Incisal Tooth Fragment reattached with different Materials and Preparation (레진재료와 치아형성 방법에 따른 파절편 재부착치아의 파절저항성)

  • Kim, Jongsung;Kim, Gimin;Lee, Jaesik;Kim, Hyunjung;Nam, Soonhyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.104-112
    • /
    • 2022
  • The purpose of this study is to analyze the fracture resistance of reattached tooth according to the resin materials and tooth preparation type under physiological conditions. Uncomplicated crown fracture in the oblique direction was reproduced on the extracted 64 anterior teeth. Depending on the composite resin material, reattachment was performed using a flowable resin and a packable resin. Depending on retentive forms, reattachment was performed using simple reattachment, 1.0 mm × 1.0 mm labial chamfer bevel, 1.0 mm × 1.0 mm lingual chamfer bevel and 1.0 mm × 1.0 mm circumferential bevel. A load was applied to the palatal surface of the tooth using a universal testing machine at an angle of 125 degree, which is the interincisal angle of normal children. Under the masticatory pressure condition, fracture resistance of lingual chamfer groups was 28.28 ± 7.41 MPa and 27.54 ± 4.45 MPa, which was significantly higher than those of simple reattachment groups, 17.21 ± 5.87 MPa and 20.10 ± 6.00 MPa, in both flowable and packable resin groups. When considering the lingual force similar to masticatory pressure, the fragment retention was significantly improved when the lingual chamfer was formed compared to the simple reattachment. Clinicians may consider the design of the lingual chamfer in order to improve fracture resistance to masticatory pressure during fragment reattachment.

Long-Term Outcome of Reattached Tooth Fragment in Permanent Anterior Teeth of Children and Adolescents (소아 및 청소년의 영구치 치관 파절시 파절편 재부착술의 추적 관찰)

  • Kang, Hoyeon;Chae, Yongkwon;Lee, Koeun;Lee, Hyo-seol;Choi, Sungchul;Nam, Okhyung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.42-49
    • /
    • 2021
  • This study aimed to evaluate the long-term outcomes of teeth treated with reattachment technique in children and adolescents. Twenty seven permanent anterior teeth from 21 patients treated with fragment reattachment were evaluated. Clinical photos and medical records were used to assess treatment outcomes. Effect of pulp treatment and the ratio of fragment on success rate were statistically analyzed. Detachment of fragment was observed in 17 teeth, and their duration of retention was 21.41 ± 23.39 months. Repeated trauma was found to be the most frequent causes of failure. Pulp treatment before reattachment did not affect the success rate (p > 0.05). The mean ratio of fragment was 0.482 ± 0.147, and the success rate was affected by the ratio of fragment (p = 0.018). The median retention time of the teeth was 72 months if the ratio was under 0.5, and 8 months for that of the others. A significant correlation was found between the ratio of fragment and retention time (p = 0.003). Reattachment can be a predictable treatment option for crown fracture in anterior teeth in children and adolescents when a fracture involves less than 50% of the clinical crown.

EDISON_CFD를 이용한 초음속 이중압축램프에서 난류 모델에 따른 유동현상 비교

  • Sin, Ho-Cheol
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.585-589
    • /
    • 2015
  • 본 연구에서는 이중압축램프의 초음속 유동에서 발생하는 충격파 경계층 상호작용을 EDISON_CFD로 해석하기로 한다. 이중압축램프에선 역압력 구배로 인하여 경계층이 박리가 일어나게 되고 박리된 경계층이 다시 이중압축램프에 부착되어 생겨난 박리영역을 관찰할 수 있다. 박리영역의 앞뒤로 유동의 방향이 바뀌게 되면서 압축 팬(compression fan)과 재부착 팬(reattachment fan)이 충격파를 발생시키고 이중압축램프전방의 충격파와 만나서 복잡한 유동 구조를 가지게 됨을 확인하였다. 이와 같은 층류에서 난류, 박리와 재부착의 영역에서의 해석하기 위해선 해석자의 난류모델이 중요하다. $15^{\circ}-30^{\circ}$, $15^{\circ}-45^{\circ}$의 두 종류의 이중압축램프를 $k-{\omega}$ SST 난류 모델과 ${\gamma}-Re_{\theta}$ 천이 모델로 계산을 EDISON_CFD로 수행하였다. 난류 모델의 차이를 표면마찰계수, 압력계수, 마하수로 비교하여 차이점을 분석하였다.

  • PDF

Conservative and esthetic approach in crown fracture of maxillay anterior tooth: tooth fragment reattachment (상악 전치부 치관 파절의 보존적이고 심미적인 접근법: 파절편 재부착)

  • Jung, Kyoung-Hwa;Kwon, Eun-Young;Kim, So-Yeun;Jeon, Hye-Mi;Son, Sung-Ae;Park, Jeong-Kil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.105-112
    • /
    • 2019
  • Crown fractures are the most frequent traumatic injuries to permanent teeth and mainly involve the maxillary incisors due to their exposed position in the dental arch. One option for managing crown fractures, when the tooth fragment is present and in good condition, is reattachment of the fragment to its original position. This paper reports on three crown fracture cases in which successful esthetic and functional results were achieved by reattachment of the tooth fragment.

Management of complicated crown fracture by tooth fragment reattachment with fiber post: a case report (섬유 강화형 포스트를 이용한 치관 파절된 치아의 재부착: 증례보고)

  • Kim, Yu-Ri;Jung, Kyoung-Hwa;Son, Sung-Ae;Park, Jeong-Kil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.251-258
    • /
    • 2021
  • Dental trauma is very common in children and relatively young people, with the line of treatment depending on the time elapsed, age of the child, and tooth maturity. If the fractured segment is available and there is close approximation of the segment to the remaining tooth, reattachment of the fractured segment is a feasible option. This treatment offers several advantages, including the reestablishment of function, aesthetics, shape, shine and surface texture, in addition to the original contour and alignment of the teeth. The following cases present two different complex crown fracture cases that were treated using tooth fragment reattachment with fiber-reinforced composite post.

One-visit Apexification Using MTA and Reattachment of a Crown-root Fractured Tooth with Severe Coronal Damage: A Case Report (심한 치관 손상이 발생한 치관-치근 파절 치아의 일회 내원 치근관형성술 및 파절편 재부착 : 증례 보고)

  • Park, Youngjun;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.521-527
    • /
    • 2018
  • In dental trauma, reattachment of the original tooth fragment improves the reproduction of original tooth shape, texture, color, and radiolucency; thus, it provides good aesthetics. A 9-year-old boy was referred due to complicated crown-root fracture of the maxillary right central incisor. Although it had poor prognosis due to severe coronal damage and subcrestal fracture, reattachment of the tooth fragment was chosen due to the patient's age. One-visit apexification with mineral trioxide aggregate (MTA) was performed, followed by osteotomy and reattachment of the tooth fragment with post placement. Regular observation revealed no clinical signs or symptoms and no radiologic complications.

Measured Effect of Shock Wave on the Stability Limits of Supersonic Hydrogen-Air Flames (충격파가 초음속 수소-공기 화염의 안정한계에 미치는 영향)

  • Hwanil Huh
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.86-94
    • /
    • 1999
  • Measured shock wave effects were investigated by changing shock strength and position with particular emphasis on the stability limits of hydrogen-air jet flames. For this purpose, a supersonic nonpremixed, jet-like flame was stabilized along the axis of a Mach 2.5 wind tunnel, and wedges were mounted on the sidewall in order to interact oblique shock waves with the flame. This experiment was the first reacting flow experiment interacting with shock waves. Schilieren visualization pictures, wall static pressures, and flame stability limits were measured and compared to corresponding flames without shock-flame interaction. Substantial improvements in the flame stability limits were achieved by properly interacting the shock waves with the flameholding recirculation zone. The reason for the significant improvement in flame stability limits is believed to be the adverse pressure gradient caused by the shock, which can elongate the recirculation zone.

  • PDF

A Study on the Effect of Hull Appendages of High-Speed Catamarans with Modified-reverse bow on the Running Performance (반전형 선수부 형상을 갖는 고속 쌍동선의 부가물이 주행성능에 미치는 영향에 관한 연구)

  • Kim, Do-jung;Na, Hyun-ho;Kim, Jung-eun;Oh, Do-won;Choi, Hong-sik
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.601-608
    • /
    • 2019
  • In this study, the effect of hull appendages on the high-speed catamarans with reverse bow shapes is compared and analyzed by numerical analysis and circulating water tank model test. The reverse bow shape showed an improved wave shape by shifting the generation position of forward divergent wave to the stern direction and was effective in resistance and stable running posture (Kim et al., 2019). In the model test results of the running performance as the wave patterns and the change of the running posture due to the fin fitted with the inner side of the inverted bow and the interceptor, 1) Trim characteristics of the inverted bow 2) Improvement of superposition of inner wave by Fin 3) The trim control by the fin and the interceptor is considered to be effective in reducing the impact of the two hull connection decks (wetdeck).

Performance analysis of the axisymmetric mufflers by BEM (BEM을 이용한 축대칭 소음기의 성능해석)

  • 임정빈;정갑철;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.306-311
    • /
    • 1994
  • 본 연구에서는 축대칭 형태의 음향문제를 해석할 수 있는 경계요소 프로그램을 개발하여 소음기의 투과손실(transmission loss)의 계산에 적용하였다. 우선 단순팽창관 소음기에 대해서는 경계요소법에 의해 투과손실을 구한 후 평면파이론 및 실험으로 구한 값과 비교 평가하였다. 또한, 평면파이론을 적용할 수 없는 경우로서 흡음재를 부착한 팽창관 소음기에 대해서는 경계요소법으로 구한 투과손실을 실험결과와 비교 고찰하였다.

  • PDF