• Title/Summary/Keyword: 재하속도

Search Result 134, Processing Time 0.034 seconds

Crack Growth and Debonding Behaviors of the Pre-cracked RC Beams Repaired with Carbon Fiber Sheets (사전균열로 손상된 RC 보의 탄소섬유시트 보수 후의 균열성장 및 박락거동)

  • Kim, Chung Ho;Ko, Sin Woong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.121-129
    • /
    • 2006
  • This study look into the mechanisms of growth and magnification of the cracks and delamination in the pre-cracked RC beams repaired with carbon fiber sheets. The experimental parameters were loading type, loading speed and crack. In the experiments, it was confirmed that a failure of beams began with development and propagation of the stepped delamination in the below the loading point due to the rapid change of shear force, but mechanisms of the failure were not influenced with loading type, loading speed and pre-cracks. Particularly, in the case of beams having the pre-cracks, growth of crack concentrated at the special crack below the loading point and led to failure of the beam by delamination due to magnification of crack.

Loading Rate Effect on the Lateral Response of H-Shape Steel Column (재하속도가 H-형강 기둥부재의 횡방향 거동에 미치는 영향)

  • Park, Minseok;Kim, Chul-Young;Han, Jongwook;Chae, Yunbyeong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.637-644
    • /
    • 2021
  • Dynamic response of structures can be evaluated experimentally by conducting cyclic loading tests. It has been known that steel materials are rate-dependent and the lateral response of a structure is significantly affected by the presence of axial force. However, the rate-dependency of steel column structures subjected to both axial and lateral loads has not been sufficiently studied yet due to the difficulty of controlling the axial force in a real-time manner during test. This study introduces an advanced way to apply the axial load in real-time to a column specimen using the adaptive time series (ATS) compensator and the flexible loading beam (FLB), where the H-shape steel columns made of SS275 are used for monotonic and cyclic loading tests with various loading rates with axial loads. The lateral strength and post-yield response of the steel columns are compared for each of monotonic and cyclic loading tests. The estimating equation of yield stress of various strain rate has proposed and finite element analysis were performed for comparison.

A Simple Method for Predicting Lateral Earth Pressure in Consideration of Construction Speed of Embankment (성토 재하속도를 고려한 측방토압의 간이예측법)

  • Im, Eun-Sang;Kim, Hyoung-Soo;Kim, Tae-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1055-1060
    • /
    • 2005
  • In evaluating the stability of underground structures and designing prevention methods against the lateral flow, it is necessary to predict the amount and the distribution of the lateral earth pressure acting on these retaining structures. However, because the lateral deformation of real ground is a very complex phenomenon influenced by interaction between volumetric deformation bringing an increase of stability of ground and shear deformation causing failure of ground, any appropriate methods for estimating the lateral earth pressure in consideration of the geotechnical properties of ground and the construction conditions in embankment have not been developed as yet. Therefore, a prediction method, which considers effects of a construction speed of embankment, using the Boussinesq's solution based on the elasticity theory without using complex numerical analyses such as finite element analyses is proposed in this research.

  • PDF

A Study on the Sensitivity of Reinforced Concrete Element Design Factors (변형율속도변화에 대한 철근콘크리트부재 설계인자의 민감성 연구)

  • Sim, Jong Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.4
    • /
    • pp.9-14
    • /
    • 1989
  • A strain rate-dependent element model was used to study the loading rate-sensitivity of R/C beams and columns with different design factors. Conclusions were derived regarding the differences between the element axial/flexural performance under impulsive and quasi-static loads. Practical design formalas for predicting the loading rate-dependent axial and flexural strengths of R/C elements were also suggested.

  • PDF

Response Analysis of PSC-I Girder Bridges for Vehicle's Velocity (재하차량 속도에 따른 PSC-I 거더 교량의 거동분석)

  • Park, Moon-Ho;Kim, Ki-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.127-134
    • /
    • 2008
  • The response of a bridge can be influenced by span length, bridge's surface condition, vehicle's weight, and vehicle's velocity. It is difficult to predict accurate behavior of a bridge. In the current standard of specifications, such dynamic effect is defined by impact factor and prescribed to consider live load as to increase design load by means of multiplying this value by live load. However, it is not well understood because the Impact factor method differs from every country. Dynamic, static and pseudo-staitic field loading tests on PSC-I girder bridges were carried out to find out the dynamic property of the bridge. This paper is aimed to figure out actual dynamic property of the bridge by using field loading test. An empirical method based on impact factor is widely used and also argued. Displacement and strain response measured from the tests was compared with one from the empirical method. The former seems to be reasonable since it can consider actual response of a bridge through field tests.

Lateral Earth Pressure Caused by Action on Earth Retaining Wall in Clay Foundation Ground with Consideration of Construction Speed (지중 구조물에 작용하는 측방토압에 대한 성토 재하 속도의 영향)

  • Im Eun-Sang;Lee Kang-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.57-68
    • /
    • 2004
  • When an embankment is constructed on soft clay ground, the lateral displacement generally called as lateral flow is generated in the foundation ground. It strongly affects stabilities of structures, such as foundation piles and underground pipes, in and on the foundation ground. The lateral earth pressure induced by the lateral flow is influenced by the magnitude and construction speed of embankment, the geometric conditions and geotechnical characteristics of the embankment, and the foundation ground, and so on. Accurate methods for estimating the lateral earth pressure have not ever been established because the lateral flow of a foundation ground shows very complicated behavior, which is caused by the interaction of shear deformation and volumetric deformation. In this paper, a series of model tests were carried out in order to clarify effects of construction speed of an embankment on the lateral earth pressure in a foundation ground were design. It was found that the magnitude and the distribution of the lateral earth pressure and its change with time are dependent on the construction speed of the embankment. It was found that a mechanism for the lateral earth pressure was generated by excess pore water pressure due to negative dilatancy induced by shear deformation under the different conditions of construction speeds of embankments.

Effect of Loading Rate to Bearing Capacities (지지력에 미치는 재하속도에 관한 해석적 연구)

  • 박중배
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.147-158
    • /
    • 1997
  • In this study, it is examined that partial drain has an effect of bearing capacities and deformations on intermediate soils. To compare the numerical and experimental results, this study uses CRISP90 which is composed of Modify Cam-Clay Model for calculation and Geotechnical Centrifuge in model test. As the results of analysis, we can classify relative loading rate into three ranges which are drain, undrain and partial drain. Besides it is proved that partial drain range is about 103.

  • PDF

Determination of Proper Loading Speed for Deformation Strength Test of Asphalt Concretes (아스팔트 콘크리트 변형강도 시험에서의 적정 하중재하속도 선정 연구)

  • Cho, Byung-J.;Park, Tae-W.;Doh, Young-S.;Kim, Kwang-W.
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.225-234
    • /
    • 2008
  • This study was carried out to select proper loading speed for deformation strength ($S_D$) of asphalt mixtures. Kim test using loading head of diameter(40mm) with radius(10mm) was conducted to measure $S_D$ in different loading speed (10mm/min, 30mm/min, 50mm/min, 70mm/min) and wheel tracking test was also conducted. The regression analyses between the So values and WT results were carried out by loading speeds. Higher $S_D$ was observed as increasing loading speed. This means that loading speed is a high influencing factor on $S_D$. The loading speed of 30mm/min was found as an optimum for better correlation with WT results than any other speeds from the regression analysis between $S_D$ and wheel tracking test results. $S_D$ value measured at other loading speed than 30mm/min has to apply the conversion coefficients.

  • PDF

Investigating the Influence of Rate Dependency and Axial Force on the Seismic Performance Evaluation of Isolation Bearing (면진받침의 내진성능평가를 위한 실험 시 속도의존성과 수직하중의 영향)

  • Minseok Park;Yunbyeong Chae;Chul-Young Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.22-29
    • /
    • 2023
  • In the evaluation of seismic performance for structural materials and components, the loading rate and axial force can have a significant impact. Due to time-delay effects between input and output displacements, It is difficult to apply high-rate displacement in cyclic tests and hybrid simulations. Additionally, the difficulty of maintaining a consistent vertical load in the presence of lateral displacement has limited fast and real-time tests performed while maintaining a constant vertical load. In this study, slow, fast cyclic tests and real-time hybrid simulations were conducted to investigate the rate dependency and the influence of vertical loads of Isolation Bearing. In the experiment, the FLB System including an Adaptive Time Series (ATS) compensation and a state estimator was constructed for real-time control of displacement and vertical load. It was found that the vertical load from the superstructure and loading rate can have a significant impact on the strength of the seismic isolation bearing and its behavior during an earthquake. When conducting experiments for seismic performance evaluation, they must be implemented to be similar to reality. This study demonstrates the excellent performance of the system built and used for seismic performance evaluation and enables accurate and efficient seismic performance evaluation.

An Improved Analytical Model for Considering Strain Rate Effects on Reinforced Concrete Element Behavior (변형률 속도를 고려한 철근콘크리트부재 거동 예측을 위한 개선된 해석모델)

  • Sim, Jong Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.23-29
    • /
    • 1989
  • The strain rate-sensitive constitutive models of steel and concrete were incorporated into a refined analytical procedure for loading rate-dependent axial/flexural analysis of reinforced concrete beam-columns. The predictions of the analytical technique compared well with both quasi-static and dynamic test results on reinforced concrete elements.

  • PDF