• Title/Summary/Keyword: 재질 시험

Search Result 447, Processing Time 0.03 seconds

A Study of Life about Naturally Aged Nitrocellulose by Storage (자연 노화된 니트로셀룰로오스의 수명에 관한 연구)

  • Kim, Dong-seong;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.595-601
    • /
    • 2020
  • During the safety inspection of nitrocellulose-made explosive containers stored for more than 10 years, cracks were found in the containers. Therefore, a failure cause analysis test was performed. First, the cause of failure through the failure tree analysis was conducted to select the factors that influenced failure. The changes in the properties of the container caused by the acceleration of the reaction were found to be the cause of the failure by confirming the influence on the environment and internal/external factors that may occur during storage. To confirm this, environmental tests, such as thermal shock test and vacuum thermal stability test, were performed using a naturally aged container to analyze the cause of failure, and an accelerated aging test was performed to reproduce the failure. Through this, the chemical reaction was accelerated by heat and charge, as in the result of the fault tree analysis, and it was confirmed that the physical properties of the container were changed. In addition, the service life of the container was estimated using the Arrhenius model for the storage life due to thermal aging.

Reliability Demonstration Test Method for Electromagnetic Shielding Doorset with a Sub-Unit Subjected to Preventive Replacement (예방교체부품을 가지는 전자파차폐용 문세트의 신뢰성입증시험법)

  • Shin, Jung-Hun;Lee, Hyo-Kyung;Jang, Jin;Kim, Do-Sik;Nam, Tae-Yeon;Jung, Dong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1171-1177
    • /
    • 2014
  • An electromagnetic shielding doorset must satisfy requirements associated with both mechanical strength/durability and electromagnetic shielding. Among the primary components of the doorset, a finger strip-a leaftype spring normally made of beryllium copper-is a core part to shield electromagnetic waves as well as to endure repetitive dry sliding friction. This study presented a reliability demonstration test method for the doorset system and, by a simple and simultaneous implementation, of the replacement interval of the finger strip. A rigorous evaluation for the qualification of maintenance or replacement interval is included in the reliability demonstration test of any series system that holds critical maintenance sub-units.

An Experimental Study on Fire-Resistant Boom (내화용 오일붐의 내화성에 대한 실험적 연구)

  • Yu J.S.;Sung H.G.;Oh J.H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.2
    • /
    • pp.25-32
    • /
    • 2000
  • Fire-resistant boom is one of the most important facilities in in situ homing of spilled oil. Thermal response of a fire-resistant boom to turning is experimentally investigated in this paper by using an electric furnace and a burning test facility. This test facility is composed of a test tank, a fire boom, a hood for inhaling smoke, an incinerator for burning up gases and thermocouples, etc. Thereby a systematic method of approach in small laboratory scale is developed to study the performance of a fire-resistant boom. Burning test is carried out for the fire boom model which has been developed through the present study. It is shown that the present fire boom model has capability to withstand the high temperature around 800℃ and high rate of heat flux on it due to homing. For more realistic experimental environments, larger dimensions in devices and longer time in experiments are recommended in near future.

  • PDF

The Study on Structural Strength Test Technique by Using Compressed Air Type Loading Method (공기압식 외력부가방법을 이용한 구조강도 시험기법 연구)

  • Kim, Jong-Hwan;Lee, Kee-Bhum;Kim, Ho-Yeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.376-381
    • /
    • 2010
  • The structural strength tests are usually performed to evaluate the structural strength and to verify the structural design and analysis of the vehicle structures. In this paper, the development of a compressed loading type apparatus to load distributed force over the surface of vehicle structure subjected to external loads was described. This apparatus is for structural materials which are easily to fail because of concentrated stresses. This apparatus can apply loads to specimens without any damage on the test specimen's surfaces by using flexible membrane and can be applicable to several kinds of surface profile of structures. The structural strength tests for the flat structure and curved structure with this apparatus were successfully performed, and the test results showed that this type of loading apparatus can be adequate to verify the structural integrity of the fragile structures.

Burning Tests for Interior Flooring Materials (건축용 바닥재의 연소성능 시험)

  • Lee, Bong-Woo;Lee, Jang-Won;SaKong, Seong-Ho;Kim, Hee-Soo;Lee, Byoung-Ho;Kim, Hyun-Joong
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.30-37
    • /
    • 2008
  • We have performed the inflammability test for various flooring materials through a radiant heat panel tester by using the specification KSISO 9239-1 (an examination method of flooring materials) that has been set as an international standard for the fire prevention means of interior flooring materials. We have measured the flame spread distance, critical heat flux and smoke density generated by the fire of various flooring materials while using the radiant heat panel tester. The measurement result has shown the burning characteristics different from each other by the respective flooring materials and we could see that the surface materials and construction elements influence greatly on the heat release and smoke generation. We could see that the evaluation method above is an important test method in evaluating the critical heat flux, smoke generation and flame spread distance that are Important factors in studying for fire risks and it is judged that setting and applying a fire evaluation method of flooring materials suitable for the domestic construction use would be relevant.

Estimation of Vertical Load Capacity of PCFT Hybrid Composite Piles Using Dynamic Load Tests (동재하시험을 통한 긴장력이 도입된 콘크리트 충전 강관말뚝을 사용한 복합말뚝의 연직지지력 평가)

  • Park, Nowon;Paik, Kyuho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.3
    • /
    • pp.31-38
    • /
    • 2019
  • To determine the optimum dynamic load test analysis for PCFT (Prestressed Concrete Filled steel Tube) hybrid composite piles that PCFT piles are connected to the top of PHC piles, the dynamic load tests and CAPWAP analyses were performed on two hybrid composite piles with steel pipe and PCFT piles as upper piles. The results of the dynamic load tests and CAPWAP analyses showed that the particle velocity measured in PCFT hybrid composite piles was equal to the wave speed of PHC piles when the strain gauges and accelerometers are attached to the surface of inner composite PHC pile after removing the steel pipe in the upper PCFT pile. In addition, when assuming that the material of that upper PCFT pile was the same as that of the lower PHC pile and the cross-sectional area of the steel pipe in upper PCFT pile was converted to that for concrete through the pile model (PM) in CAPWAP analysis, the accuracy of the CAPWAP analysis result for PCFT hybrid composite piles was very high.

Fracture Study due to Various Core at Compact Tension Specimen Made of Carbon Fiber Reinforced Plastic (탄소성유강화플라스틱으로 만들어진 소형 인장 시험편에서 여러 종류의 심재에 따른 파손 연구)

  • Kim, Jae-Won;Cho, Jae-Ung
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.3
    • /
    • pp.589-596
    • /
    • 2018
  • Transportation or structure has the important role at clothing, food, and housing at modern society. If even the small crack happens and propagates at transportation or structure, the parts are fractured and they can cause a disaster. CT specimen was used in order to investigate the damage trend due to the crack propagation at this study to prevent this situation. As the material of CT specimen, the unidirectional carbon fiber reinforced plastic of the composite material in the limelight nowadays. The laminate angle designated in order of [60/-60/60/-60] was applied to the specimen model with the unidirectional fiber. As the analysis condition, the forced displacement was applied to the hole of upper part after fixing the hole of lower part. At the result of this study, the equivalent stress and shear stress was shown to be higher in order of the structural steel, copper, titanium and aluminum. This study result is thought to be utilized usefully at verifying the damage of CT specimen made of inhomogeneous material.

Research of Electrical Safety Test Construction about Structure under 765kV Transmission Lines (765kV 송전선로 선하 건조물 전기안전 실증시험 구축 연구)

  • Mun, Seong-duk;Maeng, Jong-ho;An, Ho-sung;Ahn, Heesung;Lee, Ho-guen
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.410-411
    • /
    • 2015
  • 765kV 송전선로와 선하 건조물은 최하단 도체의 높이 28m를 적용하고 대지저항률은 $100{\Omega}m$, IEEE 변전소 설계지침인 Std-80에 따라 건조물에 접촉하는 사람의 인체저항은 $1000{\Omega}m$, 대지를 딛고 있는 사람의 한쪽 발 접지저항은 직경 8cm의 원판 접지저항을 적용한다. 이렇게 구성된 모델에서 선로중심에서 건조물까지 이격거리 변동에 따라 인체 유도전류를 측정하고자 한다. 본 연구에서는 전기안전 실증시험을 위해 765kV 가공송전선로 직하에 목조 및 샌드위치 판넬 2가지 시험용 가옥을 설치하였다. 전기설비기술기준에 의거하여 선하직하 이격거리가 28m일 때 발생할 수 있는 전자계 특성과 재질에 따른 전자계가 미치는 영향을 비교 분석하고 장기 유도장해 실측 데이터를 확보하고자 그림 1과 같이 구축 설계하였다. 이를 통해 송전선로에 의해 선로중심으로부터 구축된 모의가옥까지 이격거리에 따라 유도되는 전류를 측정하고 그 크기가 인체에 미치는 유도전류 한계치 초과 여부에 대해 검토함으로써 안전성 여부에 대해 측정 및 검토하고자 시험게획을 수립하였다. 또한 선로 고장 시 대지전위상승에 의한 선하 건조물 안정성 검토 및 낙뢰서지 유입에 의한 전기안전 시험 구성을 하였다.

  • PDF

Numerical Simulation of Triaxial Compression Test Using the GREAT Cell: Preliminary Study (GREAT 셀을 이용한 삼축압축시험의 수치모사: 예비연구)

  • Park, Dohyun;Park, Chan-Hee
    • Tunnel and Underground Space
    • /
    • v.32 no.3
    • /
    • pp.219-230
    • /
    • 2022
  • The Geo-Reservoir Experimental Analogue Technology (GREAT) cell was designed to recreate the thermal-hydro-mechanical conditions of deep subsurface in the laboratory. This apparatus can generate a polyaxial stress field using lateral loading elements, which rotate around the longitudinal axis of a sample and is capable of performing a fluid flow test for samples containing fractures. In the present study, numerical simulations were carried out for triaxial compression tests using the GREAT cell and the mechanical behavior of samples under different conditions of lateral loading was investigated. We simulated an actual case, in which triaxial compression tests were conducted for a polymer sample without fractures, and compared the results between the numerical analysis and experiment. The surface strain (circumferential strain) of the sample was analyzed for equal and non-equal horizontal confining pressures. The results of the comparison showed a good consistency. Additionally, for synthetic cases with a fracture, we investigated the effect of the friction and type of fracture surface on the deformation behavior.

An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service (PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구)

  • Park, Jeong-Hwa;Oh, Cheon-Young;Kwark, Ji-Heon;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • In this study, to determine whether it is possible to apply Polyethylene (PE) compound pipe, which was developed to solve the problem caused by the corrosion of the fire protection piping currently in usein water based fire extinguishing systems, we performed an actual mockup fire test. Since no test standard was available related to the developed compound pipe, we compared and analyzed domestic and international technical materials and test standards and selected suitable fire test standards to evaluate the performance of the PE compound pipe. we applied two fire test standards to the PE compound pipe, viz. those for CPVC and metallic pipes, and conducted a total of 6 experiments to evaluate its performance. According to the results of the first and second fire tests based on the test standard for the CPVC pipe, neither the fitting nor the piping was damaged or deformed and no leakage was observed in the pressure test, which was performed for 5 minutes. For the fire test based on the metallic pipe test standard, a total of 4 experiments were conducted. The first two experiments were conducted to simulate the wet piping system. In the results of this fire test, neither leakage nor rupture was observed from the PE compound pipe and no damage was caused, such as the secession of the PE material. However, in the next two experiments, which simulated the dry system, the PE compound pipe suffered damage and rupture, including deformation before the fire fighting water was discharged. Therefore, we found that the piping performance of the PE compound pipe did not undergo any deterioration, including fusion, deformation, or damage, in the wet piping system simulated fire test.