• 제목/요약/키워드: 재실자

Search Result 99, Processing Time 0.03 seconds

A Comparative Study on the Occupant Evacuation Behavior Model of Domestic and Foreign in Long Term Care Hospital (국내·외 요양병원의 재실자 피난행동 모델에 관한 비교연구)

  • Choi, Yun-Ju;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.166-167
    • /
    • 2021
  • The elderly population in Korea is constantly increasing. As the number of Long-Term Care hospitals increases, many fires have occurred in related facilities. In this facilities, due to the characteristics of the occupants, self-evacuation is difficult, resulting in a number of casualties. It is necessary to Life safety design that reflects the characteristics of the occupants of domestic long-term hospitals. The study attempted to suggest improvements to the standards of evacuation behavior model for occupants of domestic and overseas long-term care hospitals. As a result of the study, patients living in long-term hospitals have a problem that is difficult to evacuate on their own. It is judged that there is a need to present an evacuation behavior model database by setting evacuation priorities and evacuation plans. In addition, it is necessary to more the design factors that affect the evacuation model as well as the characteristics of the occupants of the long-term care hospital.

  • PDF

Case Study about Performance Based Design through Fire & Egress Simulation for Atrium of A Hotel & Casino (A 호텔 & 카지노 아트리움의 화재 및 피난시뮬레이션을 통한 성능위주설계 사례연구)

  • Park, Chang-Bok;Lee, Yong-Ju;Kim, Min-Ju;Yoon, Myong-O;Choi, Young-Hwa;Park, Jae-Sung;Kim, Hwan-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.13-19
    • /
    • 2009
  • This study is related with fire risk assessment for occupant of the area adjacent to not enclosed atrium through the computer modeling and application of enhanced fire protection systems depending on the result. Fire scenario is intended to evaluate the impact of a fire from atrium base within the corridor adjacent to the atrium and to compare with egress time depending on the warning system. The major purpose of this study is to figure out fire life safety for occupant adjacent to atrium through the computer simulation and to suggest alternative option in case the occupant safety is not guaranteed.

A Study on the Necessity of an Addressable Emergency Broadcasting System to Improve Evacuation Performance (피난성능향상을 위한 주소형 비상방송시스템의 필요성에 관한 연구)

  • Kim, Si-Kuk;Lee, Min-Yong;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.14-22
    • /
    • 2015
  • This thesis is based on the study of necessity of an addressable emergency broadcasting system to improve evacuation performance in order to minimize human casualty by avoiding the initial evacuation after fires such as the multi-unit dwelling fire in Euijeongbu in 2015. To minimize the damage from fire generated in a complex internal structure such as modern buildings, introduction of adaptable emergency broadcasting system, could increase the efficiency of evacuation by preventing of initial mistaken evacuation directions by alerting the accurate location of fire to the occupants, is needed. As such, this study designed and fabricated the addressable emergency broadcasting system using the existing addressable system. Its performance was compared with a conventional emergency broadcasting system to confirm the necessity of the addressable emergency broadcasting system to improve evacuation performance. The test result showed that the addressable emergency broadcasting system decreased the evacuation time by up to 30.3% in a small-scale model evacuation performance experiment, up to 54.6% in a hallway evacuation performance experiment compared to the conventional emergency broadcasting system.

A Study on the BEMS Installation and performance Evaluation Method for Energy Monitoring(Measuring) of New Building (신축건물 에너지효율관리를 위한 환경 및 에너지모니터링(계측) 방법론)

  • Kwon, Won Jung;Yoon, Ji Hye;Kwon, Dong Myung
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.32-48
    • /
    • 2018
  • Monitoring of energy use should be a priority in order to efficiently manage building energy use. Energy use in buildings can be managed by dividing them into energy sources, uses, and ZONE. By energy source, electricity, gas, fuel, and district heating are supplied to run the building's facilities. The purpose can be divided into five main applications, including cooling, heating, lighting, hot water and ventilation, but not many elevators and electric heaters that are difficult to include in the five applications are classified. ZONE Star refers to the comparison or separate management of areas for which the purpose of the building is similar or different. In addition, energy efficiency management requires control of the temperature, humidity, and people who will be measuring energy in the building, and the recent problem of fine dust should directly affect the ventilation of the building.

A Study on the Main Characteristics and Factors of the Process of Beginning Egress during the Fire at the Buildings - Focus on Overseas Fire Cases including the Japanese - (건축물 화재 시 피난개시과정의 주요 특성 및 요소에 관한 연구 - 일본 등 해외 화재사례를 중심으로 -)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.59-68
    • /
    • 2012
  • Predicting occupants' behaviors from the start of the fire to egress and reducing the time required for such process are critical matters that can decide success and failure of safe egress. In this research, research literatures and theories and fire cases were compared and analyzed so as to prepare logical grounds that could predict the process of beginning egress. As a result of this research, there was a significant difference in the time elapsed until people start evacuating due to spatial positions and quarantine from the place from which the fire originated and their auditive and olfactory signs did not recognize the fire instantly and they showed a strong tendency to recognize the fire by visual sign, warning announcement for egress and notice by others. And the results also showed that only a very small minority of occupants evacuated as soon as they perceived the fire and that variation in the time elapsed until evacuation begun for occupants were wider as the size of building was bigger and that accommodations such as hotel had wider variation in the time elapsed regardless of the size of buildings.

Estimating occupied university classroom acoustical parameters from unoccupied values (대학 강의실의 공석 시 측정값을 이용한 만석 시 음향지표의 예측)

  • Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.343-348
    • /
    • 2018
  • This paper proposes a simple procedure for estimating the acoustical parameter values in an occupied classroom from measurements in the unoccupied classroom. The total sound absorption in an unoccupied classroom can be calculated from measured reverberation times in the room. The expected occupied absorption can be calculated using equation that was obtained in a previous study (Choi, 2016) by fitting a linear regression line to a plot of total occupied absorption versus the corresponding unoccupied total absorption values measured in 12 university classrooms. The ratios of occupied-to-unoccupied sound absorption are used to predict increments in the values of acoustical parameters when occupants are added to the rooms. Occupied values of acoustical parameters can be estimated from unoccupied values and the change in total room absorption due to adding occupants.

A Study on Eco-friendly Indoor Space of Domestic Eco-certified (LEED)Building through the Cases Analysis & User's Satisfaction (LEED인증 건축물 분석을 통한 실내공간의 친환경성 개선방안에 관한 연구)

  • Na, Min-Hee;Han, Hae-Ryon
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.233-240
    • /
    • 2013
  • The building construction sector has been blamed as the main culprit of environmental contamination worldwide. So, there shall be some constructive alternatives in architectural engineering. As one of the alternatives, the LEED ("Leadership in Energy and Environmental Design") has been introduced since 1990s and has been well recognized in saving the resources and energy. "LEED" has also been introduced in Korea since 2002 but it has not put priority on the eco-friendliness of indoor space. In this study, the international and domestic green systems were analyzed and compared in order to restructure the checklist for indoor space. Using the restructured checklists, the questionnaire were sent to 180 people using 6 office buildings which passed the domestic "LEED" certification. LEED certification system put priority on the air quality and heating/cooling environment in its evaluation section and items. However, according to the results of the study, it was found that the people using the buildings were not satisfied enough with the air environment of buildings along with their other indoor environment items. This shows that even though the office buildings are designed according to the requirements of LEED, the buildings do not meet the occupier's needs. In addition, it showed that the evaluation items should be improved so that they are useful to enhance the satisfaction of the occupiers' needs. The paper could be useful in establishing standard for eco friendliness of indoor space of office buildings which pass the LEED certification as the basic data for increasing energy efficiency and working efficiency of occupiers of the buildings.

Evacuation Behaviors under the Corridor and Stair Width Variations in Evacuation Experiments (복도·계단 폭 변화를 통한 피난실험에서 피난행태에 미치는 영향요인 분석)

  • Lee, Jeong-Soo;Kwon, Heung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2374-2381
    • /
    • 2012
  • The aims of this study are to verify the effecting factors in evacuation behavior under the corridor and stair width variation in evacuation experiments at university education facilities. To achieve these purposes, the present conditions of university education facilities were analyzed, and the evacuation experiment settings were established under different width of corridor and stairs. After the experiments, we asked the effecting variables to the evacuation behaviors under the variation of corridor, stair width and density of evacuee. The results of this study are as follows ; First, we found 3 main factors which affecting the evacuation behaviors ; environmental factors on building conditions, psychological factors on evacuee's characteristics and personal factors on evacuee's physical conditions. Second, the environmental factors such as the location of stairs for evacuation, recognition of wayfinding in fire condition are mainly affects the evacuation behaviors, but evacuee behaviors have little relations with fire extinguishing facilities and personality.

A Study on the Evacuation Performance Review for the Office Buildings (업무용 빌딩의 피난 성능 검토에 관한 연구)

  • 오혁진;백승태;김우석;이수경
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.1-6
    • /
    • 2003
  • In this study, it reviewed about evacuation performance of a specified Office Building. assessment tools is FAST 3.1.7 (Estimation of Flash Over, Estimation of Layer Height Down Flow Time), SIMULEX 32-bit (Estimation of Evacuation Time), JASMINE 3.25d. (Smoke Flow Assessment of a specified time) Result from Fire Scenario # 1, Flash Over is not generated in Compartment. Evacuation Time is estimated 25.2 sec by SIMULEX 32-bit. layer height until this time (25.2 sec) was estimated 2.4 m by FAST 3.1.7. After ignition until this time (25.2 sec), smoke was not release to the a corridor. In consequence, We concluded that people in building are completing the safe evacuation without the damage of smoke. Result from Fire Scenario # 1, Flash Over generated 6 min 33.2 sec in Compartment. Evacuation Time is estimated 1 min 25.5 sec by SIMULEX 32-bit. layer height down flow time is 1 min 40.8 sec by FAST 3.1.7 and 5 min 23 sec by theoretical calculation. Also, total building evacuation time was estimated 2 min 26.6 sec. After ignition until this time (2 min 26.6 sec), smoke released to the a corridor but it amount was few little. Therefore, generated smoke in compartment not effected to the people in buildings.

A Study for the Fire Hazard Evaluation through the Fire Simulation of an Apartment Fire Accident (아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.69-78
    • /
    • 2010
  • In this study, Fire Hazards were evaluated through computer simulation using FDS program for an apartment fire accident. The results of fire simulation showed that the maximum heat release rate in the case of no sprinklers activation was 7,700 kW which was about 16 times of that in the case of sprinklers activation, 497 kW and there was a very high fire hazard due to the backdraft phenomenon when the door of fire room was forced to open. Regarding the hazard time of fire room temperature and detection time of detectors, available evacuation time was 32.5 seconds of minimum to 53.5 seconds of maximum. In the case of sprinklers activation, fire hazard in the apartment was showed to be very low due to the fire control by the spray cooling of sprinklers. This study shows that what a important function for fire safety is the activations of fire sprinkler system and emergency alarm system and what a large loss can cause if these systems don’t activate in fire accidents.