• Title/Summary/Keyword: 재실자특성

Search Result 26, Processing Time 0.016 seconds

A Study on the Main Characteristics and Factors of the Process of Beginning Egress during the Fire at the Buildings - Focus on Overseas Fire Cases including the Japanese - (건축물 화재 시 피난개시과정의 주요 특성 및 요소에 관한 연구 - 일본 등 해외 화재사례를 중심으로 -)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.59-68
    • /
    • 2012
  • Predicting occupants' behaviors from the start of the fire to egress and reducing the time required for such process are critical matters that can decide success and failure of safe egress. In this research, research literatures and theories and fire cases were compared and analyzed so as to prepare logical grounds that could predict the process of beginning egress. As a result of this research, there was a significant difference in the time elapsed until people start evacuating due to spatial positions and quarantine from the place from which the fire originated and their auditive and olfactory signs did not recognize the fire instantly and they showed a strong tendency to recognize the fire by visual sign, warning announcement for egress and notice by others. And the results also showed that only a very small minority of occupants evacuated as soon as they perceived the fire and that variation in the time elapsed until evacuation begun for occupants were wider as the size of building was bigger and that accommodations such as hotel had wider variation in the time elapsed regardless of the size of buildings.

A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System (기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.31-37
    • /
    • 2012
  • This paper describes to analyze the ventilation performance of a room air conditioner for indoor comfort control. An experimental apparatus consists of a test room, the room air conditioner, a tracer gas measurement system, a supply fan and a controller. Ventilation performance as a function of human occupancy is evaluated with supply ventilation air using a tracer gas technique of CO2 gas in the test room. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 and is found to increase with increasing supply ventilation rate. The CO2 gas concentration is decayed rapidly without human occupancy. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570 lpm comparing with a natural reduction after one hour. A modeling for ventilation performance of a room air conditioner in a test room is presented using experimental datum.

Smartphone-based Wavelength Control LED Lighting System according to the Sleep-Wake Cycle of Occupants (재실자의 수면-각성 주기에 따른 스마트폰 기반 파장제어 LED 조명시스템)

  • Kim, Yang-Soo;Kwon, Sook-Youn;Hwang, Jun;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Melatonin hormone involved in human's circadian rhythm adjustment sensitively responds to light's specific short wavelength ratio. A shift worker's circadian rhythm disturbance and sleep disorder are caused by the existing lighting conditions, whose short wavelength ratio is fixed. The life pattern of a shift worker changes irregularly because of irregular working hours and the same lighting environment; thus, his/her concentration is reduced. For such a reason, negative effects ensue to the detriment of healthy everyday life, including a high risk of accidents or having unsound sleep after leaving work. A smartphone-based wavelength control LED lighting system that targets shift workers and that can easily measure and control lighting suitable for wake-sleep cycle, according to working hours and closing hours, is proposed in this paper. First, after the light characteristics of LED lighting that changes depending on light control ratio are measured through the color sensor installed on the smartphone and the externally-linked Mini-Spectrometer, they are stored in the database. Based on the stored optical characteristics data, the measurement module and light control module are implemented. Lighting is offered using a control ratio having the maximum rate of short wavelength in consideration of the target illuminance, classified according to work type by identifying working hours as time when waking is required for shift workers. After a shift work leaves work, the amount of lighting is varied, using a control ratio having a minimum short wavelength rate so that a shift worker can enter the sleep state naturally.

A Study on Fire and Evacuation simulation analysis for use of Disaster Vulnerable Personal Evacuation Device (재난약자 대피 도움장치 활용을 위한 화재 피난 시뮬레이션 분석 연구)

  • Choi, Doo Chan;Hwang, Hyun Soo;Ko, Min Hyeok;Lee, Si Yu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.824-831
    • /
    • 2020
  • Purpose: In fire case, nursing hospitals are subject to considerable restrictions on evacuation due to the characteristics of occupants and vulnerable elements of buildings, it is important to make evacuation device for vulunerabale person, and need how to intend to increase the efficiency of evacuation by fire and evacuation simulation with helper Method: The smoke characteristics were analyzed by time through fire simulation, finally, the number of helpers according to the day and night was entered, and the evacuation completion time was compared and analyzed using the evacuation simulation. Result: It was found that the evacuation time was shortened by more than 20% when the evacuation assistance device was used for the vulnerable, and the evacuation time was delayed by almost 70% in case of a fire at night compared to the daytime. Conclusion: If the horizontal and vertical evacuation device are effectively utilized in actual fire situations, a strategy appropriate to the situation is deemed necessary. It is expected that evacuation efficiency will increase based on the use of horizontal evacuation evacuation device and vertical evacuation device by developing evacuation manuals

Evaluation of the acoustic environments of open-plan offices in Korean public buildings (국내 공공건축물 개방형 사무실 음환경 평가)

  • Sang Hee Park;Hye-Kyung Shin;Seung-Min Lee;Kyoung Woo Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.42-49
    • /
    • 2023
  • Poor indoor acoustic environments negatively affect occupants. Previous research has shown that indoor acoustic environments affect not only task performance and job satisfaction of the occupants, but also their health and well-being. This study aimed for evaluating indoor acoustic environments of open-plan offices located in public buildings in Korea. It also aimed to review the matters that need to be considered in order to improve occupants' acoustic comfort. Indoor noise levels were measured in 13 sites; the measurements were conducted for five consecutive working days from Monday to Friday. The noise levels were evaluated based on the levels recommended by the ISO and the EU ALDREN project. The study found that most of the indoor noise levels measured in the sampled sites during the working hours met the ISO standard. In the case of the levels under unoccupied conditions at night, those at three sites did not meet the recommendation of the ALDREN. In addition, some characteristics of the sites had significant effects on the noise level. Since the exact acoustic performance of the building envelope could not be identified, future research is needed for investigating the relationship between accurate building performance and indoor acoustic environments.

Impact of Indoor Air Quality on the Eye Conditions of Occupants in Newly-built University Buildings (새 학교 건물 내 실내공기질이 재실자의 안구에 미치는 영향)

  • Kim, Woo-Jae;Kim, Sun-Duk;Kim, Hyojin;Kim, Ho-Hyun;Lee, Cheol-Min;Kim, Yoon-Shin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.201-207
    • /
    • 2011
  • Purpose: This study was to find out the influence on eyes of indoor air quality in college students taking course, such as Sick-building syndrome symptoms and effects on the eye in new-built university buildings. Methods: We selected a new building in a university located in Metro Seoul and college students in a department for the study. The number of total participants was 33, to whom questionnaire surveys were conducted in advance to check individual traits (gender, age, whether to smoke, whether to wear contact lenses, or whether to drink). The first questionnaire surveys and checking of ocular symptoms to first indoor hazardous materials were conducted in October and two months later the second surveys and checking were carried out in December. The indoor air quality was measured when conducting the first questionnaire surveys and the second questionnaire surveys; especially measurements of gaseous materials such as aldehydes and VOCs in the indoor air were conducted. Results: Indoor air quality of the new building was as follows: formaldehyde level was 22.90 ${\mu}g/m^3$ in the first measurement and 16.79 ${\mu}g/m^3$ in the second measurement. In addition, most materials showed higher value in the first measurement. The level of TVOC was statistically significant (p<0.05) decreased on 448.54 ${\mu}g/m^3$ in the first and 62.55 ${\mu}g/m^3$ in the second. In clinical assessments to check ocular symptoms caused by eye irritations, dry eye syndrome was found in the first and second exposures. When comparing the first and second assessments, dry eyes deteriorated in the morning of the second attempt compared to the first one. Conclusions: In the survey of ocular symptoms and the measurement of indoor air quality, the level of formaldehyde was measured higher in the second attempt than the first; thus, it was confirmed the influence of indoor air quality in a new building upon ocular symptoms of occupants.