• Title/Summary/Keyword: 재부착

Search Result 957, Processing Time 0.026 seconds

층류 박리된 관유동에 관한 실험적 연구

  • 이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.4
    • /
    • pp.937-944
    • /
    • 1990
  • 본 연구에서는 파이프내에 부분 오리피스판을 장착하여 이 장애벽 전후에서 발생하는 유동현상을 박리 전단층의 유동구조와 재부착 경계층을 중심으로 실험적으로 연구하였다. 측정방법으로 유동의 속도장변화를 구하기 위하여 NMR 위상 영상법을 사용하였고, 과망간산칼륨을 염료로 가시화 실험을 수행하여 그 결과를 비교 검토하였 다.

A Study on Boundary Layer Behavior of an NACA 0012 Airfoil (NACA 0012 에어포일의 경계층 거동에 관한 연구)

  • 양재훈;장조원
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.16-23
    • /
    • 2006
  • A study on the boundary layer behavior of an NACA 0012 airfoil at low Reynolds numbers was investigated in order to gain knowledge of a boundary layer that might be employed in a turbine blade and MAVs. A hot-wire anemometer was used to measure the boundary layer of an NACA 0012 airfoil at static angles of attack ${\alpha}$=$0^{\circ}$, $3^{\circ}$, and $6^{\circ}$, and Reynolds Numbers Re=$2.3{\times}10^4$, $3.3{\times}10^4$, and $4.8{\times}10^4$. The results of this study show that the laminar boundary layer on the airfoil surface is attached to the surface at ${\alpha}$=$0^{\circ}$, and the laminar separation of the boundary layer on the airfoil surface occurs at ${\alpha}$=$3^{\circ}$. Furthermore, the reattachment of the boundary layer in the present study occurs for the cases of Re=$3.3{\times}10^4$ and Re=$4.8{\times}10^4$at ${\alpha}$=$6^{\circ}$.

Avulsion of Aortic Commissure: Rare Cause of Aortic Regurgitation - 2 case reports - (교련부 분리에 의해 발생한 대동맥판 역류 - 치험 2예 -)

  • Choi, Jae-Woong;Hwang, Ho-Young;Choi, Eun-Suk;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.777-780
    • /
    • 2009
  • We reported here on 2 cases of aortic regurgitation (AR) that were due to avulsion of the aortic valve commissure. Aortic valvuloplasty was attempted in both cases. In the 1st case, valvuloplasty was performed with reattaching the commissure using the 5-0 polypropylene continuous suture technique. However, aortic regurgitation recurred and this lead to reoperation on the postoperative $14^{th}$ day. The intraoperative finding revealed a completely re-detached commissure that required mechanical valve replacement. In the second case, we attempted to reattach the commissure using pledgetted multiple transverse mattress sutures with 5-0 polypropylene. Because the leaflet coaptation was incomplete, the aortic valve was replaced with a tissue valve.

Evaluation of Adhesion Performance of High-Fireproofing Alumino-silicate Inorganic Mortar (알루미노 실리케이트계 고내화성 모르타르의 부착성능 평가)

  • Cho, Hyeon-Seo;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.569-576
    • /
    • 2018
  • In modern society, a huge number of the buildings have been constructed with RC structure. RC structures have many structural instabilities due to earthquake, typhoon, construction fault, design phase errors. Therefore, many reinforcement methods are being implemented to solve this problem. In the reinforcement method, the organic epoxy adhesive used in the FRP reinforcing method is abruptly damaged when exposed to high temperature, which is directly connected to the fall of the reinforcing material. Therefore, the present study was conducted to develop inorganic refractory mortar with a certain level of adhesion ability to reduce the heat transferred to FRP reinforcement when exposed to high temperatures. As a result of the test, it showed high adhesion strength at room temperature condition with the inclusion of EVA resin, and showed no performance deterioration up to about $300^{\circ}C$ even under heating conditions. Also, it was confirmed that the backside temperature was lower as the thickness increased, and converged to a constant temperature of about $780^{\circ}C$ after 2 hours of heating.

Numerical Simulation of Turbulent Heat Transfer in Locally-Forced Separated and Reattaching Flow (국소교란에 의한 박리 재부착 유동에서의 난류 열전달 수치해석)

  • Ri, Gwang-Hun;Seong, Hyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.87-95
    • /
    • 2001
  • A numerical study was made of heat transfer in locally-forced turbulent separated and reattaching flow over a backward-facing step. The local forcing was given to the flow by means of sinusoidally oscillating jet from a separation line. A Rhee and Sung version of the unsteady $\kappa$-$\varepsilon$-f(sub)u model and the diffusivity tensor heat transfer model were employed. The Reynolds number was fixed at Re(sub)H=33,000 and the forcing frequency was varied in the range 0$\leq$fH/U(sub)$\infty$$\leq$2. The condition of constant heat flux was imposed at the bottom wall. The predicted results were compared and validated with the experimental data of Chun and Sung and Vogel and Eaton. The enhancement of heat transfer in turbulent separated and reattaching flow by local forcing was evaluated and analyzed.

Numerical Simulation of Turbulent Separated and Reattaching Flows by Local Forcing (국소교란에 의한 난류박리 재부착 유동의 수치해석)

  • Rhee, Gwang-Hoon;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.467-476
    • /
    • 2000
  • An unsteady numerical simulation was performed for locally-forced separated and reattaching flow over a backward-facing step. The local forcing was given to the separated and reattaching flow by means of a sinusoidally oscillating jet from a separation line. A version of the $k-{\varepsilon}-f_{\mu}$ model was employed, in which the near-wall behavior without reference to distance and the nonequilibrium effect in the recirculation region were incorporated. The Reynolds number based on the step height (H) was fixed at $Re_H=33000$, and the forcing frequency was varied in the range $0{\leq}St_H{\leq}2$. The predicted results were compared and validated with the experimental data of Chun and Sung. It was shown that the unsteady locally-forced separated and reattaching flows are predicted reasonably well with the $k-{\varepsilon}-f_{\mu}$ model. To characterize the large-scale vortex evolution due to the local forcing, numerical flow visualizations were carried out.

Investigation on the Turbulence Structure of Reattaching Separated Shear Layer Past a Two-Dimensional Vetrical Fenc(I) (2次元 垂直壁을 지니는 再附着 剝離 斷層 의 亂流構造 에 관한 硏究 (I))

  • 김경천;정명균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.403-413
    • /
    • 1985
  • Hot-wire measurements of second and third-order mean products of velocity fluctuations have been made in the separated, reattached, and redeveloping boundary layer behind a vertical fence. Mean velocity, wall static pressure distributions have also been measured in the whole flow field. Upstream of the reattachment point, the separated shear layer developes as a free mixing layer, but the gradient of the maximum slope thickness, turbulent intensities and the Reynolds shear stress are higher than that of the mixing layer due to initial streamline curvature and the effects of highly turbulent recirculating flow region. In the reattachment region, Reynolds shear stress and triple products near the surface is far more rapid than the decrease of the shear stress; that is the presence of the solid wall has a marked effect on the apparent gradient diffusivity of intensity or shear stress and throws doubts upon the usefulness of the simple gradient diffusivity model in this region.

Examination of Tensile and Adhesion Performance According to Components and Application Environment of Cement-mixed Polymer-based Waterproofing (시멘트 혼입 폴리머계 방수재의 구성요소 및 적용환경에 따른 인장·부착성능 평가)

  • Lee, Jin-Yong;Choi, Jeong-Kyun;Kim, Seong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.41-49
    • /
    • 2021
  • Cement-mixed polymer-based waterproofing materials are generally used in the form of application by mixing in the field, and it is necessary to supplement the construction ability for air bubbles and uneven coating thickness due to irregularities during construction. The final purpose of this study is to improve the waterproofing performance by adding a sheet attaching process to the composite construction rather than the single process of painting and applying the construction method when applying the polymer waterproofing material to the field. In this regard, the applicability was evaluated by examining the material, environment, and manufacturing method.

Structural Capacity of RC Beam Retrofitted by CFS with Bond Loss (탄소섬유로 휨보강된 RC 보의 부착 손실에 대한 거동 특성)

  • Seo, Soo-Yeon;Yun, Hyun-Do;Choi, Ki-Bong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.795-802
    • /
    • 2007
  • Recently, various strengthening methods using carbon fiber sheets (CFS) have been developed for the rehabilitation of structures and applied to the concrete member. However, still research need arises in order to verify the structural capacity of RC member which experienced bond loss between concrete and CFS after strengthening. This is because previous research has focused on the development of design process and evaluation of structural capacity only for retrofit. The appearance of this loss may be initiated at just after retrofit construction. And it will be more serious when the layer number of CFS increases. In order to minimize above mistake in retrofit design using CFS, more exact evaluation process to predict the bond loss of CFS is required. The objective of this research is to study the variation of flexural structural capacity of beam which has experienced bond loss after strengthening using CFS. Experimental and analytical study are performed and evaluation of the previous formula is conducted. Test result showed that the significant strength deterioration was not found until the bond loss of 20%. Overall structural behavior of the beams can be predicted by nonlinear sectional analysis.

Field Application of a Precast Concrete-panel Retaining Wall Adhered to In-situ Ground (원지반 부착식 판넬옹벽의 현장 적용성 평가)

  • Min, Kyoung-Nam;Lee, Jae-Won;Lee, Jung-Gwan;Kang, In-Kyu;Ahn, Tae-Bong
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.51-61
    • /
    • 2016
  • New building methods are needed to aid increased inner-city redevelopment and industrial construction. A particular area of improvement is the efficient use of cut slopes, with the minimization of associated problems. A retaining wall of precast panels can resist the horizontal earth pressure by increasing the shear strength of the ground and reinforcing it through contact with the panels. Precast panels allow quick construction and avoid the problem of concrete deterioration. Other problems to be solved include the digging of borrow pits, the disposal of material cut from the slope, and degradation of the landscape caused by the exposed concrete retaining wall.This study suggest the methods of improvement of an existing precast panel wall system by changing the appearance of the panels to that of natural rock and improving the process of adhering the panel to a vertical slope. The panels were tested in the laboratory and in the field. The laboratory test verified their specific strength and behavior, and the field test assessed the panels' ground adherence at a vertical cutting. Reinforcement of the cutting slope was also measured and compared with the results of 3D numerical analysis. The results of laboratory test, identified that the shear bar increase the punching resistance of panel. And as a results of test construction, identified the construct ability and field applicability of the panel wall system adhered to in-situ ground. In addition to that, extended measurement and numerical analysis, identified the long-term stability of panel wall system adhered to in-situ ground.