DOI QR코드

DOI QR Code

Examination of Tensile and Adhesion Performance According to Components and Application Environment of Cement-mixed Polymer-based Waterproofing

시멘트 혼입 폴리머계 방수재의 구성요소 및 적용환경에 따른 인장·부착성능 평가

  • Received : 2021.09.02
  • Accepted : 2021.11.08
  • Published : 2021.12.31

Abstract

Cement-mixed polymer-based waterproofing materials are generally used in the form of application by mixing in the field, and it is necessary to supplement the construction ability for air bubbles and uneven coating thickness due to irregularities during construction. The final purpose of this study is to improve the waterproofing performance by adding a sheet attaching process to the composite construction rather than the single process of painting and applying the construction method when applying the polymer waterproofing material to the field. In this regard, the applicability was evaluated by examining the material, environment, and manufacturing method.

시멘트 혼입 폴리머계 방수재는 일반적으로 현장에서 배합하여 도포 형태로 사용되는 경우로 시공 시 발생되는 기포, 요철로 인한 불균일한 도막두께 등에 대한 시공능력을 보완해야 할 필요가 있다. 본 연구의 최종 목적은 폴리머 방수재의 현장 적용 시 시공방법을 도장·도포하는 단일공정에 그치지 않고 시트를 부착하는 공정을 추가하여 이에 대한 성능을 검토하는 것이다. 이에 대하여 재료, 환경, 제작방법 등을 검토하여 적용성을 평가하였다.

Keywords

References

  1. Park, H. M., Choi, J. Y., and Kim, S. W. (2006), Characteristics of Waterproofing System on Concrete Bridge Deck. Journal of the Korea Concrete Institute, 18(3), 20-25. (In Korean)
  2. Lee, B. D., and Ahn, T. S. (2006), Causes and Improvements of Deterioration of Waterproofing Systems in Concrete Bridge Decks. Magazine of the Korea Concrete Institute v.18 no.3, 42-50. (In Korean)
  3. Mun, K. J., Lee, C. W., Choi, N. W., Yang, S. W. and Soh, Y. S. (2005), Experimental Study on the Physical of Properties of Redispersible Polymer Powder-Modified Cementious Waterproof Coating Materials, Journal of the Architectural Institute of Korea Structure & Construction 25(1), 273-276. (In Korean)
  4. Chang, S. J. (2004), Application of Cement-polymer Modified Waterproof Membrane Coatings. Journal of the Architectural Institute of Korea. April. 131-141. (In Korean)
  5. Kim, Y. G., Oh, S. K. and Park, B. K., (2003), A Study on Physical Properties of Cement-Polymer Modified Waterproof Membrane Coatings. Journal of the Architectural Institute of Korea Structure & Construction 19(9), 79-86. (In Korean)
  6. Yun. S. H. (2015), A Fundamental Study on The Physical Properties of Polymer-Modified Paste-Applied Membrane Waterproofing Materials by Amount of Alumina Cement. Master Thesis, Seoul National University of Science & Technology. (In Korean)