• Title/Summary/Keyword: 재난현장

Search Result 689, Processing Time 0.021 seconds

A study on alarm broadcasting method using public data and IoT sensing data (공공데이터와 IoT 센싱 데이터를 활용한 경보방송 방법에 관한 연구)

  • Ryu, Taeha;Kim, Seungcheon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.21-27
    • /
    • 2022
  • As society develops and becomes more complex, new and diverse types of disasters such as fine dust and infectious diseases are occurring. However, in the past, there was no PA(Public Address) system that provided accurate information to prepare for such a disaster. In this paper, we propose a public address system that automatically broadcasts an alarm by analyzing polluted air quality data collected from public data and IoT sensors. The warning level varies depending on the air quality, and the information provided by public data may show a significantly different result from the guide area due to various factors such as the distance from the measuring station or the wind direction. To compensate for this, we are going to propose a method for broadcasting by comparing and analyzing data obtained from public data and data from on-site IoT sensors.

A Study on the Method of Calculating the Deformation Coefficient According to the Horizontal Subgrade Reaction Modulus and Cohesion (수평지반반력계수와 점착력에 따른 지반변형계수 산정방법 연구)

  • Sungjae Jeon;Daeseock Jung
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.31-43
    • /
    • 2023
  • Purpose: In this study, an analysis of the differences between the elastoplastic analysis and the numerical analysis and a study of the design ground constant recalculation method to derive similar trends in the analysis results were conducted. Method: The relational expression between the ground reaction force coefficient and the ground deformation coefficient at the time when the wall displacement becomes the same according to shallow excavation and deep excavation was derived. Result: Based on the measurement results, reverse analysis was performed to re-calculate the ground properties suitable for the site ground, and as a result of comparing and verifying the wall displacement using the derived formula and the literature formula, the proposed formula showed the most similar value. Conclusion: If the proposed formula is used, it will be helpful in practice because it is possible to infer the most similar ground properties to the actual at the time of design.

A Study on the Geotechnical Characteristics of Jeju Area Using Field Tests (현장시험을 이용한 제주지역의 지질특성에 관한 연구)

  • Byung Jo Yoon;Sung Yun Park;Seung Jun Lee
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.769-777
    • /
    • 2022
  • Purpose: This study analyzes and studies the characteristics of the Jeju area and uses them as basic data such as construction method design in the future development project. Method: Based on the ground survey data of the construction conducted in Jeju, the depth, relative density, N value, function state, color tone, groundwater level, and compressive strength were analyzed and studied. Result: Studies show that Jeju has columnar joints consisting of ancient volcanic activity and rapid cooling by nearby seawater, thick sand layers found on the coast, and clinker layers and Seogwipo layers formed by Mercury volcanic activity. Conclusion: It is hoped that it will be used as data for selecting basic design and basic construction method by understanding the special ground form of Jeju area and reflecting its characteristics well when designing construction.

Effectiveness Analysis of Fire Extinguishing Agents for Metal Waste Fires (금속화재 대응 시 간이소화용구 및 약제의 소화 효과성 분석)

  • Jin-Suk Kwon;Su-Young Kim;Tae-Sun Kim;Tae-Hee Park;Tae-Dong Kim;Min-Young Park
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.644-655
    • /
    • 2023
  • Purpose: Metal fires occur in metal handling, processing, waste storage plants, etc. It is difficult for firefighters to extinguish metal fires, and it takes a long time, so caution is needed in fire suppression. Method: In this study, current statistics and problems of metal fires were introduced, and then the effectiveness was verified by experiments with using fire extinguishing agents used in Korea. Comparative suppression experiments of 5 different fire extinguishing agents for burning powders of 99.9% magnesium over 150 ㎛ were performed following the metal powder type test method of Class D fire in ISO 7165. Result: 5 fire extinguishing agents are the power types of dry sands and expanded vermiculites most commonly used in Korea, the certified class D fire extinguisher used abroad, and ochers requiring verification, and the liquid silica gel. Conclusion: The results of experiments showed expanded vermiculites were the best metal fire extinguishing agent considering effectiveness, convenience of use, and economical feasibility.

A Study on Automatically Information Collection of Underground Facility Using R-CNN Techniques (R-CNN 기법을 이용한 지중매설물 제원 정보 자동 추출 연구)

  • Hyunsuk Park;Kiman Hong;Yongsung Cho
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.689-697
    • /
    • 2023
  • Purpose: The purpose of this study is to automatically extract information on underground facilities using a general-purpose smartphone in the process of applying the mini-trenching method. Method: Data sets for image learning were collected under various conditions such as day and night, height, and angle, and the object detection algorithm used the R-CNN algorithm. Result: As a result of the study, F1-Score was applied as a performance evaluation index that can consider the average of accurate predictions and reproduction rates at the same time, and F1-Score was 0.76. Conclusion: The results of this study showed that it was possible to extract information on underground buried materials based on smartphones, but it is necessary to improve the precision and accuracy of the algorithm through additional securing of learning data and on-site demonstration.

A Study on the Improvement Plan for Reducing the Risk of Crowed Event (다중운집행사 리스크 저감을 위한 개선방안 연구)

  • Nam-Kwun Park
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.379-389
    • /
    • 2024
  • Purpose and Method: Crowed Events can lead to sudden accidents caused by unpredictable variables. Therefore, focusing on the '10.29 Itaewon accident' among the representative cases, we examined the accident as the process of occurrence. In addition, improvement measures were suggested through analysis of related legal systems. Result: In the Itaewon accident, a "colony wave phenomenon" occurred due to "ultra-high-density cluster stay". In addition, cluster destruction occurred from a weak location in the cluster due to clusters and pressures in different directions to avoid this. Looking at the laws related to the safety management of Crowed Events, the laws and regulations differ depending on the location and type. Due to the complementary nature of the approach to the legal blind spot, the legal system that uses similar terms of the same concept and is not systematic is causing uncertainty in the application and interpretation of the law. Conclusion: Crowd control and on-site management should be carried out for events when the cluster density is expected to reach 8 people/m2 or reached. Consistency should be maintained through the unified application of legislation to related legislation.

Research on Rapid Disaster Prevention Measures due to Leakage During Transport of Hydrochloric Acid Tank Lorry (염산 탱크로리 운송 중 누출에 따른 신속 방재방안 연구)

  • Byoung-chan Moon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.213-221
    • /
    • 2024
  • Purpose: The purpose is to find the optimal way to quickly block the leak in the event of a leak accident in a tank lorry transporting hydrochloric acid aqueous solution, a hazardous chemical, and to carry out effective disaster prevention work to minimize damage caused by the leak. Method: We organized the overall characteristics of hydrochloric acid and accidents that occurred during transportation by accident type and cause, and created a small tank that can be tested assuming a leak situation in a hydrochloric acid tanker, creating an environment similar to the leak situation, and leaking in various ways. I would like to experiment and organize blocking methods. Result: Through experiments, an effective leak blocking method was confirmed. We would like to summarize measures to quickly block a leak in the event of a leak and present the optimal disaster prevention plan that can be applied at the accident site. Conclusion: It has been confirmed that using a combination of adhesive tape and magnets is more effective in blocking leaks. Rapid response is possible by repeatedly training business emergency response teams and product transporters to appropriately select and respond to leak-blocking equipment. Additional research on various leak prevention methods is needed in the future.

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.

Study on the Fire Cause Analysis for Explosives Waste by Thermal Analysis Experiment (열분석 실험에 의한 화약류 폐기물의 화재원인분석에 관한 연구)

  • Koh, Jae-Sun
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.1
    • /
    • pp.89-100
    • /
    • 2018
  • when the explosive wastes to be treated as designated wastes are brought into the wastes treatment plant by mistake and lead to an explosion in the wastes disposal process, many people and property damage are involved. Waste should be treated properly. As mentioned in this paper, ignition reac- tion tests of ignitable re-burning of explosives packing material waste (solid butadiene) confirmed that ignition was easily occurred, and that even small ignition sources were easily ignited and burned quickly and explosively. In particular, when explosives are loaded into incineration wastes in large quantities and mixed with organic compound wastes, such as fire and explosion accidents caused by explosives packing materials at waste disposal sites, flammable and oxidative gases are generated due to mutual oxidation and pyrolysis It is confirmed that there is a possibility that ignition sources such as spark ignite and instantaneously lead to explosion. It is hoped that this study will be a small reference for on - site detection in the field of fire, and it is expected that the fire - fighting agency will be recognized as a fire investigation agency and will contribute to the improvement of the credibility.

Estimation of Nitrate Nitrogen Concentration in Liquid Fertilizer Contaminated Areas using Hyperspectral Images (초분광 영상을 이용한 액비 오염지역의 질산성질소 농도 추정)

  • Lim, Eun Sung;Kim, I Seul;Han, Soo Jeong;Lim, Tai Yang;Song, Wonkyong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.542-549
    • /
    • 2020
  • Purpose: As nitrate nitrogen produced during fermentation of liquid fertilizer is a pollution indicator of water, in this study, four research areas where liquid fertilizer was sprayed were selected, and a model was designed to estimate the concentration of nitrate nitrogen pollution. Method: Prior to shooting on site, a spectrum library was constructed by dividing the ratio of liquid fertilizer into 5 groups: 0%, 25%, 50%, 75%, and 100%. PLSR (Partial least squares regression) method was applied to hyperspectral images acquired in the study area based on the aspect of spectrum. Result: The behavior of nitrate nitrogen was confirmed by 1st and 2nd differentiation of the spectrum of the constructed liquid fertilizer. PLSR concentration estimation modeling was implemented using images from field experiments and compared with actual concentration of nitrate nitrogen. Conclusion: When comparing the PLSR concentration estimation model with the actual concentration of nitrate nitrogen, it was measured that the detection is possible in high concentration areas where the concentration of nitrate nitrogen is 70mg/kg or more.