• Title/Summary/Keyword: 장치위치

Search Result 2,748, Processing Time 0.025 seconds

MODEL EXPERIMENT OF STOW NET (안강망어구의 모형실험)

  • KO Kwan Soh;KIM Yong Hae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.201-207
    • /
    • 1979
  • The stow net now used in the Yellow Sea, are traditional bag net with the opening held by a lighter upper and a weighted lower beams standing against the current. Such bag net anchored at the bottom are known in many countries, particularly in the estuaries of large rivers, but more rarely in sea fisheries, because they are too much affected by the weather, moreover a permanent strong current is necessary. Some scientists intended to improve this fishing gear, using the shearing devices instead of a lighter upper and a weighted lower beams in order to widen mouth of the stow net however they are unsuccessful. One-fortieth scale model net of the stow net was tested in a circular water tank with an effective volume of $5.67m\times1.76m\times1.00m$ of observing the configuration and tension of the net. Experiments were carried out under the various combination including water velocity, spherical floats and elevating floats with the shearing hoods instead of the upper beam. We found those devices offered a very low resistance per net area to current compared with the spherical floats or upper beam, and had a fairly good shearing power at any velocity and direction of the current. The total resistance (R) of the model net to which shearing hoods and floats are attached can be induced by the following formula under the condition of 0.25m/sec to 0.5m/sec, $$R(kg)=3.11V^{1.54}$$ The height (h) of the improved model net (m-B) is higher than traditional model net(m-A) with upper and lower beams, m-A: h(cm)=89.22-2.42(V-15). $V\geqq15,\;cm/sec$ m-B: h(cm)=89.20-0.78V (V:cm/sec) The catch efficiency of improved model net is 1.5 times traditional model net.

  • PDF

Vector Control for Wave Power Generation System using Permanent Magnet Linear Synchronous Generator (파력발전용 선형발전시스템의 벡터제어)

  • Park, Joon Sung;Hyon, Byong Jo;Yun, Junbo;Lee, Ju;Choi, Jang-Young;Choi, Jong-Su;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.2
    • /
    • pp.120-128
    • /
    • 2016
  • This paper describes power generation from sea waves by using linear permanent magnet generator. A buoy is placed on the ocean surface and connected to the generator. The wave energy is carried out from the movement of a buoy. An electrical conversion system is needed between the generator and the grid. For an analysis of the power system, the modeling of the linear generator and converter system was proceeded. This paper proposes vector control method for wave power generation system using linear generator. In order to verify the proposed method, simulation and experiment performed and the results support the validity of the control scheme.

Study on the Visual Characteristics and Subjectivity in the Live Action Based Virtual Reality (실사기반 가상현실 영상의 특징과 주체 구성에 대한 연구)

  • Jeon, Gyongran
    • Cartoon and Animation Studies
    • /
    • s.48
    • /
    • pp.117-139
    • /
    • 2017
  • The possibility of interactivity of digital media environment is adopted in human expression system and integrates the dynamic aspect of digital technology with expressive structure, thereby transforming the paradigm of image acceptance as well as image expression range. Virtual reality images have an important meaning in that they are changing the one-way mechanism of production and acceptance of images that lead to producers-video-audiences beyond the problem of verisimilitude such as how vividly they simulate reality. First of all, the virtual reality image is not one-sided but interactive image composed by the user. Viewing a virtual reality image does not just see the camera shine, but it gets the same view as in the real world. Therefore, the image that was controlled through framing changes to be configured positively by the user. This implies a change in the paradigm of image acceptance as well as a change in the existing form of the image itself. In addition, the narrative structure of the image and the subjects that are formed in the process are also required to be discussed. In the virtual reality image, the user 's gaze is a fusion of the gaze inside the image and the gaze outside the image. This is because the position of the user as the subject of the gaze in the virtual reality image is continuously restricted by the device of the discourse such as the editing and the narration of the shot. The significance of the virtual reality image is not aesthetically perfect but it is reconstructed according to the user to reflect the existence of the user positively and engage the user in the image.

Study of 4π Compton Suppression Spectrometer by Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 4π 컴프턴 억제 분광기 연구)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.123-129
    • /
    • 2017
  • Compton suppression apparatus using the Compton scattering response, by inhibiting part of the spectrum Compton continuum Compton continuum in the area of the peak analysis of the gamma rays that enables a clearer device. In order to find out the geometry structure of high-purity germanium detector(HPGe) -NaI(TI) and to optimize the effect of movement, Monte Carlo simulation was used to grasp the behavioral characteristics of Compton suppression and compare several layout structures. And applied to the cylinder beaker used for the environmental measurement by using the efficiency according to the distance. For the low-energy source such as 81 keV, the Compton continuum is scarcely developed and the suppression effect is also insignificant because the scattering cross-section of the Compton effect is relatively low. In the spectrum for the remaining energy, it can be seen that the Compton continuum part is suppressed in a certain energy range. Compton suppression effect was not significantly different from positional shift. average reduction factor(ARF) value was about 1.08 for 81 keV and about 1.23 for 1332.4keV energy at the highest value. It can be seen that suppression over the Compton continuum region of the energy spectrum is a more appropriate arrangement. Therefore, it can be applied to various environmental sample measurement through optimized structure.

A Study on the Development of Impact Analysis Model of Roll Control System for Course Correction Munition (탄도 수정탄 롤제어시스템 충격해석 모델 개발에 관한 연구)

  • Ko, Jun Bok;Yun, Chan Sik;Kim, Yong Dae;Kim, Wan Joo;Cho, Seung Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.737-742
    • /
    • 2015
  • Course correction munition are a weapson system for precision attacks and are assembled by applying a ballistic control system to existing projectiles. The roll control system is a subsystem of the ballistic control system and is placed between the guidance and control units inside of the projectile, which undergoes a 5000g lateral acceleration. Thus, it is very important to design the system to endure this load. Many developed countries evaluate the performance and safety of course correction munitions' parts using live-fire gun launch tests or a soft recovery system. However, these methods are expensive and slow. Thus, in this study, we develop impact analysis model of the roll control system using CAE. We apply the code to simulate impact phenomenon and use Johnson-Cook material model for modeling the high strain rate effect on the materials. We also design bearings in detail to analyze their behavior and verify the reliability of CAE model through gas-gun impact tests of the roll control system.

Development of Disassembly Tool for Intermediate Examination of Nuclear Fuel Rods (핵연료봉 중간검사를 위한 장탈착 툴 개발)

  • Hong, Jintae;Heo, Sung-Ho;Kim, Ka-Hye;Park, Sung-Jae;Joung, Chang-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2014
  • To check the characteristics of nuclear fuels during an irradiation test, the nuclear fuel rod needs to be disassembled from the test rig located in the pool of the research reactor. Then, the disassembled fuel rod is delivered to the hot cell for intermediate examination. A fuel rod that passes the intermediate examination is delivered to the reactor pool to be reassembled into the test rig. The irradiation test is resumed with the reassembled test rig. Because nuclear fuel rods irradiated by neutrons are highly radioactive, all the disassembly and reassembly processes should be carried out in the pool of the research reactor to prevent operators being exposed to radiation. In particular, because a test rig is 5.4-m long and the reactor pool of HANARO is 6-m deep, special tools need to be developed for performing the disassembly and reassembly processes. In this study, a new assembly design of nuclear fuel rods for intermediate examination is introduced. Furthermore, tools for treating the irradiated fuel rod assembly are introduced, and their performance is verified by an out pile test.

Sensitivity Analysis of Nozzle Geometry Variables for Estimating Residual Stress in RPV CRDM Penetration Nozzle (원자로 상부헤드 관통노즐의 잔류응력 예측을 위한 노즐 형상 변수 민감도 연구)

  • Bae, Hong Yeol;Oh, Chang Young;Kim, Yun Jae;Kim, Kwon Hee;Chae, Soo Won;Kim, Ju Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.387-395
    • /
    • 2013
  • Recently, several circumferential cracks were found in the control rod drive mechanism (CRDM) nozzles of U.S. nuclear power plants. According to the accident analyses, coolant leaks were caused by primary water stress corrosion cracking (PWSCC). The tensile residual stresses caused by welding, corrosion sensitive materials, and boric acid solution cause PWSCC. Therefore, an exact estimation of the residual stress is important for reliable operation. In this study, finite element simulations were conducted to investigate the effects of the tube geometry (thickness and radius) on the residual stresses in a J-groove weld for different CRDM tube locations. Two different tube locations were considered (center-hole and steepest side hill tube), and the tube radius and thickness variables ($r_o/t$=2, 3, 4) included two different reference values ($r_o$=51.6, t=16.9mm).

Measurements of Greenhouse Gas from the Manure in the Piggery (축산 돈사에서 온실가스 측정 방법에 대한 연구)

  • Kam, D.H.;Park, K.H.;Choi, D.Y.;Jung, M.S.;Min, B.R.;Lee, D.W.;Kim, J.K.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.155-162
    • /
    • 2011
  • This study was conducted to suggest the measurement procedure and to build up national greenhouse gas inventory database of animal agricultural sector by assessing methane and nitrous oxide emissions according to IPCC guidelines for national greenhouse gas inventory report in order to correspond to the Climate Change Convention. Ten house-made steady-state Half dome floating chambers were used to collect air samples emitted from slurry stored in the pit under the slat. Those chambers were spread out in order that air samples might represent the whole area of slurry under the slat. Fresh air was pumped into the chambers by $5{\sim}9{\ell}/min$ and air inside the chambers was sampled by $1{\ell}/min$. Surplus air by the higher flow rate of fresh air than sampling flow rate was passed through a hole on the top of chambers. Nitrous oxide fluxes measured from 10 locations would be negligible as concentrations between background air and sampled air from the chambers were within the error range. However, mean $CH_4$ fluxes were $0.15{\sim}1.02mg/m^2{\cdot}s$. The application of continuous greenhouse gas measurement techniques would be preferred if the patterns of greenhouse gas emissions are considered.

Study on Exposure Dose According to Change of Source to Image Distance and Additional Filter Using Abdomen Phantom (복부팬텀을 이용한 SID 변화와 부가필터 유무에 따른 피폭선량에 관한 연구)

  • Kim, Ki-Won;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.407-414
    • /
    • 2016
  • This study is to minimize the patient dose and maintain the image quality according to change of source to image receptor distance and applying additional filter. In this study, we used the DR system, the tissue-equivalent abdomen phantom and the aluminium filter. The exposure conditions were set to 80 kVp using AEC mode. The collimation size was $16{\times}16inch$. The exposure dose were measured 10 times when the SID was changed with 100, 110, 120 and 130 cm, respectively. The pirana 657 for dosimeter was located on center of radiation irradiation. The acquired images were analyzed by using the image J. In the results, the tube current was increased with increasing the SID but ESD was decreased with increasing the SID. The decrease of ESD attribute to use of filter that remove the photon of lower energy. In the histogram results using image J, there were differences between the ESD and the exposure conditions according to change of SID. However, there were not differences in histogram. Therefore, the exposure dose could reduced when set the longer SID. For pediatric exam, the exposure dose could reduced when used the aluminium filter.

One Click Film (OCF) Dosimetry System for Routine QA (주기적 정도관리를 위한 One Click Film (OCF) 선량측정 시스템)

  • Kim So Young;Yi Byong Yong;Joo Kwan Sik;Kim Jong Heon;Ahn Seung Do;Lee Sang Wook;Choi Eun Kyoung
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.375-380
    • /
    • 2002
  • Purpose : To develop a practical film dosimetry system for routine Quality Assurance (QA). Materials and Methods :An One Click Film (OCF) Dosimetry system was designed to perform swift routine QA with functions including automatic fog value elimination, angle adjustment, automatic symmetry calculation, and realtime profile generation with the ability to display realtime three-dimensional dose distributions. Results : The most frequently used functions for routine QA, such as the elimination of the fog value, conversion into an H&D curve, symmetry, and isodose distribution, can be achieved with only one click. Conclusion : Reliable results were achieved with the OCF dosimetry with simpler steps than other commercially available film dosimetry systems for routine QA. More research on the refined user interface will make this system be clinically useful.