• Title/Summary/Keyword: 잡음력스펙트럼

Search Result 18, Processing Time 0.019 seconds

Evaluation of Image Quality for Scattered X-rays using in Digital Radiography (디지털방사선영상에서 산란선의 영상특성 평가)

  • Kim, Hansol;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.395-403
    • /
    • 2022
  • Flat-panel detector (FPD) used in digital radiographic imaging systems was used to perform a quantitative power spectrum evaluation as a result of the thickness change of polymethyl methacrylate (PMMA), a tissue equivalent. As the PMMA thickness increases with the resolution-chart phantom image, the effect of the scattering line increases, indicating that the modulation characteristics decrease, and the image is bright. The results show that the noise of the image increases, and noise-power spectral images are obtained by Fourier transform to confirm by spatial frequency. Thus, it can be verified that the PMMA thickness and noise are proportional through the result of evaluating the change of resolution characteristics and representing the 2D noise-power spectrum as one-dimensional values by evaluating the change of scattering line with MTF as the PMMA thickness increases in the image.

Optimation of Reactor Control System by using Random Noise (랜덤 잡음을 이용한 원자로의 제어계 최적안전운전에 관한 연구 (1))

  • 고병준;신재인
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 1969
  • Reactor power frequency spectrum measurements at various power levela-OW, 1KW, 50KW, 100KW were made with TRIGA-MARK-II. An ion chamber was exposed to reactor flux, and the fluctions in its output current were analyed in a tunable bandpass filter to get the frequency spectrum of these fluctuation. The measured frequency spectrum of pile determined the modules of modules of zero power transfer function and indicated a prompt neutron mean life time of (7.90$\pm$1.62)X10 sec based on effective delayed neutron faction of 0.0075. The absolute value of reactor power obtained by noise analysis agreed within 5% with the power meter indication at the power below 10Kw.

  • PDF

Confocal Raman Spectrum Classification Using Fisher Measure based Filtering for Basal Cell Carcinoma Detection (기저세포암종 탐지를 위한 피셔척도 필터링 기반 공초점 라만 스펙트럼 분류)

  • Min So-Hui;Kim Jin-Yeong;Baek Seong-Jun;Na Seung-Yu;Ju Jae-Beom
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.203-207
    • /
    • 2006
  • This paper deals with a problem of detecting BCC using confocal raman spectrum. Specially, we propose Fisher measure based filtering for rejection of frequency components being noisy or non-discriminative. we use PCA (principal component analysis) for reduction of feature space dimension. Also, we apply MAP detector for classification of BCC raman spectrum. The experimental results shows that our proposed method can reduce the feature dimension and also raise the detection ratio.

  • PDF

Local Region Spectral Analysis for Performance Enhancement of Dementia Classification (인지증 판별 성능 향상을 위한 스펙트럼 국부 영역 분석 방법)

  • Park, Jun-Qyu;Baek, Seong-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5150-5155
    • /
    • 2011
  • Alzheimer's disease (AD) and vascular dementia (VD) are the most common dementia. In this paper, we proposed a region selection for classification of AD, VD and normal (NOR) based on micro-Raman spectra from platelet. The preprocessing step is a smoothing followed by background elimination to the original spectra. Then we applied the minmax method for normalization. After the inspection of the preprocessed spectra, we found that 725-777, 1504-1592 and 1632-1700 $cm^{-1}$ regions are the most discriminative features in AD, VD and NOR spectra. We applied the feature transformation using PCA (principal component analysis) and NMF (nonnegative matrix factorization). The classification result of MAP(maximum a posteriori probability) involving 327 spectra transformed features using proposed local region showed about 92.8 % true classification average rate.

Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System (디지털방사선시스템에서 IEC표준을 이용한 방사선 영상 품질의 평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.289-299
    • /
    • 2015
  • The purpose of this study is to evaluate and compare the quality of digital X-ray imaging system. The image quality evaluation was conducted By using Modulation transfer function indicating the quantitative resolution of the image and the noise power spectrum showing the noise characteristics. Using a IEC61267 radiation quality was applied to the geometry to be used in clinical and geometry presented in IEC62220-1 and Additional filter, grid, the clinical dose and the MTF value of edge phantom was measured. Result of the MTF corresponding to each item(Grid, Filter, SID, kVp, mAs), the clinical condition 100cm, 180cm, measurements of the spatial frequency of the MTF IEC62220-1Geometry 150cm became similarly apparent, rather spatial frequency was also the case high in clinical conditions 100cm. NPS results, as the dose(mAs) is increased, NPS showed that reduced. The image quality evaluation using IEC61267 the Radiation quality, Image quality of the video using the clinical conditions Geometry than image quality evaluation using IEC62220-1Geometry was better. It shows that MTF and NPC in IEC and clinical condition were not significantly different. In order to apply the evaluation method of image quality applied with clinical conditions rather than the future method, to be presented evaluation of IEC standard, based on the results of the image characterization studies in this paper, the methods that shows good quality of spatial resolution and decrease NPS value as the least dose, used suitable parameters for whether or not using added filter, grid, change SID and clinical quality(kVp), dose(mAs) etc should be found. then It is believed to be able to properly maintain the actual quality of the image of the digital radiographic imaging system in clinical.

Implementation of a digital FM composite signal generator (디지털 방식 FM 합성 신호 발생기의 구현)

  • 정도영;김대용;유영갑
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.5
    • /
    • pp.1349-1359
    • /
    • 1998
  • In this paper, presented is the result of a digital implementation of a FM stereo composite signal generator. The chip utilizing DDFS(Direct Digital Frequency Synthesizer architecture is implemented using $1.0\mu\textrm{m}$ CMOS gate-array technology thereby replacing analog componentry. To verify the process of generating composite signals a conventional logic simulation method was used. The processed chip was mounted on an evaluation PCB to test and analyze to signals. According to the measurement result obtained by using a 12-bit DAC, the digital FM composite signal generator produces a 74DB spectrally pure signal over its entire tuning range, which is superior to that of analog counterpart by 14dB in it spectral reponse. And further enhancements of the spectral response is expected to be achieved by using a high resolution digital to analog converter, such as a 16-bit DAC. The resulting signals is superior to the signal of the analoy circuitry typically used, in major characteristics such as S/N ratios, accuracy, tuning stability, and signal seperation.

  • PDF

Evaluation of image Quality for Radiographic positioning using IEC Radiation Quality & Clinical condition (IEC 선질과 임상조건을 이용한 방사선영상의 품질평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.177-178
    • /
    • 2015
  • 디지털방사선영상시스템의 영상 품질을 비교하기 위해 영상의 정량적인 분해능을 나타내는 변조전달함수(MTF), 노이즈 특성을 나타내는 잡음력 스펙트럼(NPS)을 이용하여 영상 품질평가를 하였다. IEC61267 선질을 사용하여 IEC62220-1에서 제시하는 기하학적인 조건과 실제 임상에서 사용되어지는 기하학적인 조건을 사용하여 그리드 및 부가필터, 임상선량을 이용하여 edge 팬텀을 사용하여 MTF, NPS값을 측정하였다. 그리드사용 유 무, 부가필터사용 유 무, kV, 임상선량(mAs), 영상검출기까지의 거리에 따른 MTF 결과는 임상조건 100cm, 180cm과 IEC62220-1 기하학적인 조건 150cm에서 MTF 공간주파수 측정값은 비슷하게 나타났으며, 오히려 임상조건 100cm에서 공간주파수가 높게 나타나는 경우도 있었다. NPS 결과는 선량(mAs)이 증가함에 따라 감소함을 나타내었다. IEC61267 선질을 이용한 영상품질평가에서는 IEC62220-1기하학적인 조건을 이용한 품질평가보다 임상조건 기하학적인 조건을 사용한 영상의 품질이 좋았다. 본 논문의 영상특성 평가 연구 결과들을 바탕으로 향후 IEC 표준의 영상평가에서 제시하는 평가방법보다는 임상 조건을 적용한 영상특성 평가방법을 적용한다면 실제 임상의 디지털방사선영상시스템의 영상품질을 적절하게 유지할 수 있을 것으로 사료된다.

  • PDF

A Study on the Optical Receiver System for Digital Transmission System (디지털 전송 시스템을 위한 광 수신시스템에 관한 연구)

  • Kim, Sun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4462-4466
    • /
    • 2013
  • In optical system, the signal and additive noise for statistical properties of a variety of ways to evaluate the performance of the system is essential for the optimization. In this paper, performance analysis of spectrum-sliced optical system in the optical pre-amplifier in the receiver the received signal by including the error limits for the bit that is, the bit error rate (BER: Bit Error Rate) required to maintain the average optical power represents the number of photons per bit is included in this paper to digital form, noticeable signal the receiver to calculate the sensitivity of the method for the calculation was performed. The general strength of the transmission of the modulated signal and digital signal transmission was required for the comparison of optical power. As shown in Figure 3, the general strength of the digital signal transmission system for transmitting a modulated signal compared with the case is improved by at least 10dB.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.