• 제목/요약/키워드: 잠열교환

검색결과 33건 처리시간 0.022초

판형 상변화 물질 용기의 2상 열교환 현상 연구 (A Study on Two Phase Heat Exchange of Plate Type PCM Container)

  • 김석현;조성우;이채수
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.576-582
    • /
    • 1996
  • This work studies qualitative thermal characteristics of PCM cold storage medium container and its surrounding streams. Experimental parameters are initial PCM temperature and cold water flow rate. A mathematical modeling was establised to estimate temperature distribution and the cooling process. We found that the phase-change temperatures of PCM varies from 6 to $8^{\circ}C$ which is constant for other materials and that the dominant heat transfer resistance is that on the container side taking about 3/4 of the total resistance. The one dimensional mathematical model predicts experimental data quit well.

  • PDF

물의 증발잠열을 이용하는 미니채널 열교환기의 실험적 연구 (An Experimental Study of Evaporative Heat Exchangers with Mini-channels)

  • 이형주;유영준;민성기
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.245-253
    • /
    • 2010
  • 본 연구에서는 물의 증발잠열을 이용한 새로운 형태의 미니채널 열교환기의 제작 및 시험결과를 제시하였다. 서로 다른 세가지 형태의 물 유로를 가지는 열교환기를 제작하여 주어진 설계조건에서 실험을 통해 서로간의 냉각성능 및 압력손실 효과를 확인하였다. 고려된 세 가지 형태의 물 유로 형상에 대한 실험 결과 완전식각된 Type 2 열교환기의 공기 냉각성능이 가장 우수한 것으로 확인되었으며, 따라서 향후 제작성 및 열교환 성능을 고려하면 Type 2를 채택하는 것이 타당할 것으로 생각된다. 그러나 고온조건에서의 실험 결과 Type 1의 성능도 우수한 것으로 확인되어 고온조건의 운용을 고려할 경우에는 Type 1에 대한 추가의 성능 및 특성 확인시험을 통한 보다 면밀한 분석이 필요하다. 본 연구로 개발된 열교환기는 항공기용 환경조절장치 적용을 목표로 하였으며, 특히 공간과 중량의 제한이 있는 이동시스템 내에서 유한한 시간동안 외부로부터 냉매의 추가 공급 없이 많은 열을 흡수해야 하는 경우에 효과적으로 이용될 수 있을 것으로 기대된다.

  • PDF

접지층에서 대기난류의 역할과 에너지 평형 (Role of Atmospheric Turbulences and Energy Balances in the Atmospheric Surface Layer)

  • 권병혁;김근희;김광호;강동환
    • 한국습지학회지
    • /
    • 제11권1호
    • /
    • pp.105-113
    • /
    • 2009
  • 연안습지 생태계에서 열에너지 교환 과정은 매우 중요하다. 지표 열에너지 평형을 이루는 요소인 순복사플럭스, 현열 플럭스, 잠열 플럭스 그리고 토양열 플럭스를 전라남도 고흥에 위치한 수평적으로 균질하다고 판단되는 지역인 고흥만 간척지에서 관측하고 분석하였다. 열의 수송을 평가하기 위해서 5회의 집중관측 기간에 대기 난류를 측정하였고, 특히 갈대로 덮여있는 간척지에서 지표층 열에너지 수지를 분석하기 위해서는 물과 매우 미세한 입자로 구성된 토양 그리고 계절에 따라 색깔과 밀도가 변하는 식생캐노피를 고려하였다. 순복사 플럭스, 현열 플럭스, 잠열 플럭스, 토양열 플럭스를 기존의 에너지 수지방정식에 적용하여 식생과 토양과 같은 지표면 특성에 따른 열 플럭스의 특징을 조사하여 습지의 기온조절 효과에 대해 알아보았다. 에너지 수지비로 식생 성장기에는 주로 잠열 플럭스에 의해 열이 대기로 전달되는 것을 알 수 있었다. 또한 식생층은 열을 저장하여 기온의 일교차를 줄이는 역할을 한다. 여름철에 집중관측지의 기온이 주변 지역의 기온보다 보다 낮고 겨울철에는 다소높게 나타난 결과는 식생층을 포함하는 연안습지가 열환경을 조절함을 보여주었다.

  • PDF

공기 지중간 직접열교환시스템의 열성능 해석 (Analysis of the thermal performances of air-earth direct heat exchanger)

  • 김원갑;안정수;최영돈
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.112-121
    • /
    • 1997
  • This study is focused on the development and selection of optimal cool tube system to maximize its thermal performance. Cool tube is devised to reduce the heating and cooling load of building by preheating or refreshing of intake air. Finite volume method was adopted to solve the conduction problem between the cool tube and earth. We examine the cool tube system for two operating periods, a short term(12 hours) and a long term(3 months). The results of short term operations reveal that condensation significantly influences and raises the exit air temperature. For long term operations, optimum conditions of cool tube system are obtained with variations of flow-rate, depth, length and diameter of cool tube.

  • PDF

구리 모재를 이용한 초소형 히트파이프의 제작 (Fabrication of a Micro Heat Pipe using Copper substrates)

  • 조형철;최장현;박진성;양상식;유재석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1918-1920
    • /
    • 2001
  • 초소형 히트파이프는 고집적 반도체 소자에서 발생되는 열을 효과적으로 소산하기 위한 열교환 장치이다. 초소형 히트파이프는 작동유체가 상 변화 잠열을 이용한 칩 레벨의 냉각 장치이다. 작동유체는 진공으로 밀봉된 공간내에서 외부 동력 없이 모세관력에 의하여 이동한다. 본 논문에서는 실리콘보다 열전도도가 우수하여 발생되는 열을 더욱 빠르게 소산시킬 수 있는 구리 모재의 초소형 히트파이프를 제작한다. 특히, 모세관력은 히트파이프의 성능을 좌우하는 요소이다. 모세관력 향상을 위해서 구리 전기도금으로 이용하여 홈(groove)부분을 제작한다. 윅(wick) 제작, 구리판 접합, 작동유체 충전등으로 초소형 히트파이프를 제작한 후, 성능 실험한 결과를 보여준다.

  • PDF

공기 지중간 직접열교환시스템의 연중 열성능 해석 (Analysis on the thermal performances of air-earth direct heat exchanger in one year)

  • 김원갑;안정수;최영돈
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.517-526
    • /
    • 1997
  • This study is focused on the development and selection of the optimal cool tube system to maximize its thermal performance. Cool tube is devised to reduce the heating and cooling load of building by preheating or refreshing of intake air with buried pipes. Finite volume method is adopted to solve the conduction problem between the cool tube and earth. We examine the cool tube system for two operating periods, a short term(12 hours) and a long term(3 months). The results of short term operations reveal that condensation significantly influences and raises the exit air temperature. For long term operations, optimum conditions of cool tube system are obtained with variations of flow-rate, depth, length and diameter of cool tube.

  • PDF

실험을 통한 공동주택 환기시스템의 실제 운전 시 전열교환성능 검토 (An Evaluation on Energy Recovery Performance of the Ventilation System in Multi-Residential Building by Field Measurement)

  • 최연희;송두삼
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.68-73
    • /
    • 2017
  • Recently, energy recovery ventilators (ERVs) have been installed for energy saving in many multi-residential buildings in Korea. The performance of the heat exchanger of an ERV is analyzed in this study under specific indoor and outdoor conditions in a test-cell measurement. However, the performance of the heat exchanger varies according to the indoor and outdoor condition. In this study, the performance of energy recovery of the ventilation system was therefore analyzed in actual weather conditions using field measurement. Experiments were conducted under winter conditions in a multi-residential building for 20 days. Based on the measurement results, the characteristics of sensible heat and latent heat exchange rates were analyzed.

영동대설 사례와 관련된 동해상의 현열속과 잠열속 분포 특성 (Characteristics of Sensible Heat and Latent Heat Fluxes over the East Sea Related with Yeongdong Heavy Snowfall Events)

  • 김지언;권태영;이방용
    • Ocean and Polar Research
    • /
    • 제27권3호
    • /
    • pp.237-250
    • /
    • 2005
  • To investigate the air mass modification related with Yeongdong Heavy snowfall events, we examined sensible and latent heat fluxes on the East Sea, the energy exchange between atmosphere and ocean in this study. Sensible and latent heats were calculated by a bulk aerodynamic method, in which NCEP/NCAR reanalysis data and NOAA/AVHRR weekly SST data with high resolution were used. Among winter precipitation events in the Yeongdong region, 19 heavy precipitation events $(1995{\sim}2001)$ were selected and classified into three types (mountain, cold-coastal, and warm types). Mountain-type precipitation shows highly positive anomalies of sensible and latent heats over the southwestern part of the East Set When separating them into the two components due to variability of wind and temperature/ specific Humidity, it is shown that the wind components are dominant. Cold-coastal-type precipitation also shows strong positive anomalies of sensible and latent heats over the northern part and over the central-northern part of the East Sea, respectively. It is shown that the sensible heat anomalies are caused mostly by the decrease of surface air temperature. So it can be explained that cold-coastal-type precipitation is closely related with the air mass modification due to cold air advection over warm ocean surface. But in warm-type precipitation, negative anomalies are found in the sensible and latent heat distributions. From this result, it may be postulated that warm-type precipitation is affected by the internal process of the atmosphere rather than the atmosphere-ocean interaction.

환경조절장치용 미세유로형 증발열교환기의 성능특성 연구 (A Study on Performance Characteristics of an Evaporative Heat Exchanger with Mini-channels)

  • 이형주;유영준;민성기;황기영
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.247-253
    • /
    • 2011
  • 본 논문에서는 항공기 탑재용 환경조절장치에 사용하기 위한 미세유로형 증발열교환기의 성능 특성에 관한 연구결과를 제시하였다. 미세유로형 증발열교환기는 가능한한 적은 양의 냉매로 고온부의 열량을 흡수할 수 있도록 저온부 냉매의 증발잠열을 이용하고 단위 체적당 열전달 면적의 극대화를 위해 미세유로를 이용하는 개념이다. 설계된 공기 및 냉각수 유로를 에칭을 통해 가공하고, 이들을 적층하여 브레이징으로 접합한 후 입출구 포트를 용접함으로써 열교환기를 제작하였다. 제작된 열교환기는 기본 성능시험을 통해 요구조건대로 설계/제작되었음을 확인하였고, 다양한 운용조건에 대한 성능 맵 시험을 수행하여 입구 공기온도, 공기 유량 및 냉각수 유량 변화에 따른 열교환 성능특성을 정량적으로 파악하였다.

  • PDF

칠발도 Buoy자료를 이용한 해양-대기 열교환량 산출 및 파랑 특성에 관한 연구 (A Study on the Estimation of Air-Sea Heat Fluxes and the Wave Characteristics using Chilbaldo Buoy Data)

  • 윤용훈;홍성길;홍윤;이지연
    • 한국해양학회지:바다
    • /
    • 제3권1호
    • /
    • pp.9-15
    • /
    • 1998
  • 기상청에서는 1996년 7월부터 1997년 2월까지 목포앞바다의 칠발도 인접 해역에 1시간 간격으로 해양기상을 관측할 수 있는 부이를 설치하고 자료를 얻었다. 이 자료로부터 이 해역의 1일 평균 해양-대기 열교환량을 산출하고, 해양기상 상태의 특성을 조사하였다. 현열속의 경우, 7월에 최소(평균 -5.5 $Wm^{-2}$)이고, 1월에 최대(평균 12.6 $Wm^{-2}$)를 나타내고 있는데 이는 여름철에 대기가 해양으로 열을 공급하고 겨울철에는 반대로 해양에서 대기로 열을 공급하지만 그 크기는 여름철이 겨울철에 비해 작다는 것을 의미한다. 잠열속의 경우 7월에 최소(평균 -4.6 $Wm^{-2}$)를 보이고, 최대값은 11월에 월 평균 86.5 $Wm^{-2}$이고 10월에 일평균 최대값이 250$Wm^{-2}$까지 나타났다. 잠열 속은 대기가 건조해지고 바람이 강해지는 가을철에 최대가 나타나서 겨울철까지 지속된다. 파랑분석에 의하면 바람이 강한 겨울철이 여름철에 비해 높은 파의 출현율이 많았다 파주기는 4~6초의 출현율이 가장 많았고, 파향은 계절풍의 영향으로 겨울에는 북 또는 북동방향에서 유입되는 파가 우세하고, 여름에는 남, 남서 또는 서쪽에서 유입되는 파가 비교적 자주 출현하였다.

  • PDF