• Title/Summary/Keyword: 잠김 금속판

Search Result 33, Processing Time 0.021 seconds

Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures (근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교)

  • Kim, Jae-Hwa;Lee, Yun-Seok;Ahn, Tae-Keun;Choi, Jung-Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of using a locking compression plate and an unlocked plate for treating proximal humeral fractures. Materials and Methods: This study was based on 20 patients who underwent plate fixation for proximal humeral fractures out of the 87 patients with proximal humeral fractures and who were admitted from 2003 to 2007 in our hospital. Of the 20 patients, 10 were treated with a locking compression plate and the other 10 were treated with an unlocked plate. Each group was evaluated according to the humeral neck shaft angle, the period until bony union, the complications and the Constant score. The humeral neck shaft angle was based on plain x-rays taken immediately after the operation and at 6 months postoperatively. The Constant score was evaluated on the last visit to our clinic. Results: There was no significant statistical difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. Yet, there were three cases of screw migration in the unlocked plate group. Conclusion: There was no significant difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. The locking compression plate is considered to achieve more effective fixation for proximal humerus fractures because there were less complications such as screw migration.

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Treatment of Two- and Three-Part Fracture of Proximal Humerus using LCP (잠김 압박 금속판(LCP)을 이용한 상완골 근위부 이분 및 삼분 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Park, Deok-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.204-211
    • /
    • 2007
  • Purpose: To evaluate the result and complication of treatment using Locking Compression Plate (LCP) for fracture of proximal humerus. Materials and Methods: Between 2004 and 2006, 21 patients with two-part and three-part fractures of the proximal humerus were treated by LCP fixation. Their average age was 54.9 years. Postoperative mean follow-up period was 22.9 months. The reduction was qualified and complication were assessed with final radiographs. The functional outcome was evaluated by Neer's rating system. Results: By Neer's functional evaluation, mean score of shoulder function was 86.3 and 18 case (86%) had excellent or satisfactory results. There was one case of nonunion but no infection or avascular necrosis of the humeral head. No correlation was found between the final result and the type of fracture, age, gender or quality of reduction. Conclusion: We obtained satisfactory result of LCP fixation for fracture of proximal humerus in this study. LCP fixation for proximal humerus fracture is a reliable method to obtain satisfactory reduction, rigid fixation and early exercise.

3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures (3.5 mm T형 잠김 금속판을 이용한 원위 쇄골 골절의 치료 결과)

  • Lee, Churl-Woo;Kim, Hee-Chun;Roh, Jae-Young;Park, Young-Su
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system. Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case. Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.

Operative Treatment of the Displaced Midshaft Clavicle Fracture Using Precontoured Locking Compression Plate (Precontoured Locking Compression Plate를 이용한 전위성 쇄골 간부 골절의 수술적 치료)

  • Kim, Jeong Woo;Kang, Hong Je;No, Sung Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.117-122
    • /
    • 2012
  • Purpose: To assess the effectiveness of internal fixation using a precontoured locking compression plate for the treatment of the displaced clavicle fracture by analyzing both radiological and clinical outcomes. Materials and Methods: We reviewed 34 cases of displaced clavicle shaft fracture treated by internal fixation using precontoured locking compression plates between May 2009 and February 2010. Radiological outcomes were analized on the basis of bone union and the differences between the time for bone union depending on sex and age. Clinical outcomes were analyzed on the basis of quick DASH Scores and the differences in the range of motion of the affected shoulder compared to the contralateral shoulder. Results: In the radiological evaluation, all fractures showed bone union, and the average time for bone union was 12.3 weeks, without delayed unions. Time for bone union did not differ significantly with respect to sex and age (p=0.87). In the clinical evaluation, the average final quick DASH Score was 23.5 (range, 12~42). At final follow up, the range of motion after bone union in the affected shoulder was not significantly different from that of the contralateral shoulder (p=0.69). Conclusion: The internal fixation achieved using precontoured locking compression plate in displaced clavicle shaft fracture showed effective bone union and can be considered as a reliable method with fine clinical results showing early range of motion at the shoulder joint.

Metastatic Pathologic Fractures in Lower Extremities Treated with the Locking Plate (잠김 금속판을 이용한 하지의 전이성 병적 골절에 대한 치료)

  • Seo, Chang-Young;Jung, Sung-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.80-86
    • /
    • 2010
  • Purpose: The skeleton is commonly affected by metastatic cancer. The purpose of this study was to evaluate the results of treating metastatic pathologic fractures in lower extremities using locking plates. Materials and Methods: Between 2004 and 2010, we evaluated 12 patients (13 cases) of metastatic pathologic fractures in lower extremities, treated with the locking plate. Mean patient age was 62.2 years (range, 50-81 years), the locations of the fractures were; proximal femur in 2 cases, femoral mid-shaft in 3, distal femur in 3, proximal tibia in 4, and distal tibia in 1 case. The interval to wheelchair ambulation, pain relief and complications were evaluated. Additionally, we assessed operation time and postoperative blood loss. Results: Mean time from operation to wheelchair ambulation was 3.2 days (range, 1-6 days). Mean VAS scores improved from a preoperative score of 8.1 points (range, 7-9 points) to a score of 2.7 points (range, 2-4 points) at 1 week postoperatively. No early complications associated with surgery were encountered. Mean operation time was 88.4 minutes (range, 70-105 minutes), and mean postoperative blood loss was 246.5 ml (range, 130-320 ml). Conclusion: Internal fixation of metastatic pathologic fractures using a locking plate in the lower extremity can be an effective treatment option in the meta- or diaphyseal area of long bones with massive bony destruction or poor bone stock by offering early ambulation, pain relief and low postoperative complications.