• Title/Summary/Keyword: 잔향실

Search Result 123, Processing Time 0.03 seconds

Electromagnetic Field Distribution Analysis on Reverberation Chamber using Electromagnetic Diffusion Method (전자파 확산방식을 이용한 잔향실 내부의 필드 분포 해석)

  • 이광순;이중근;정삼영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.839-848
    • /
    • 2000
  • This paper presents the results of an electromagnetic field analysis for a reverberation chamber that is an alternative method of a shielded anechoic chamber, which is widely used for the analysis and measurement of electromagnetic interference and immunity test. Inside the defined test volume of the rectangular and triangular type, the Schroeder Quadratic Residue Diffuser was employed. FDTD(Finite-Difference Time-Domain) simulation method was applied to produce the field characteristics inside those reverberation chambers. According to the results, field uniformities on the aforementioned two types of reverberation chambers were correlated within $\pm$3dB, and $\pm$4.4dB tolerances, and rectangular type reverberation chamber shows an independent polarization result.

  • PDF

Analysis of Sound field in a Reverberation room (잔향실의 음장해석)

  • 권영필;임정빈;이주원;이득웅
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.124-129
    • /
    • 1996
  • 잔향실의 내부 음장을 해석한 결과 다음과 같은 결론을 얻을 수 있었다. 1) 벽면의 흡음률이 동일한 경우는 음향 임피던스의 실수항과 허수항의 변화, 즉 위상의 변화에 따른 음장의 변화가 없다. 2) 5각 형태의 잔향실은 벽면의 흡음률 변화에 따른 음장의 변화가 없다. 3) 4각 형태의 잔향실은 5각 형태의 잔향실보다는 음장이 불균일하며 벽면의 흡음률이 증가함에 따라 음압레벨이 표준편차가 커진다.

  • PDF

Effects of the Shape and the Absorption in Reverberation Rooms on the Space Variances of the Sound Pressure Level (잔향실의 형상(치수비)과 내부표면 흡음율이 음압의 공간편차에 미치는 영향)

  • 최석주;장영자
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.65-70
    • /
    • 1999
  • To examine the space variances of the sound pressure level for five different types (normal frequency spacing) of reverberation rooms, simulations were conducted using the Finite Element Method. In case of infinite surface impedance, nonrectangular reverberation rooms showed small Standard Deviations across the band of frequency, and in case of finite surface impedance, ideal rectangular reverberation rooms showed the similar results as those in irregular shaped reverberation rooms.

  • PDF

무향실과 잔향실의 설계

  • 이득웅
    • Journal of the KSME
    • /
    • v.43 no.9
    • /
    • pp.52-57
    • /
    • 2003
  • 이 글에서는 음향연구에 필요한 무향실, 잔향실의 기본 개요와 설계사항 및 성능 평가 방법에 대하여 소개하고자 한다.

  • PDF

전자파 잔향실 및 야외시험장의 복사 방출 측정결과의 상관성 추출

  • 이중근
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 2002
  • 전자파 잔향실(Reverberating Shielded Enclosure)의 개념은 전자파 차폐실(Shielded Enclosure)에서 얻어진 측정결과를 개선하기 위하여 1968년도에 제안되었다. 이후 Reverberating 또는 Mode-Stirred Chamber는 EM Immunity 측정뿐만 아니라 EMI측정에서도 많이 적용되어 왔지만, 국제 표준 방식으로 적용되어 오지 못하다가 최근 EMI 복사 전력 측정 및 EM Immunity 측정시설로 유용하게 사용될 수 있다는 점이 부각되어 국제 표준 방식으로 적용하자는 분위기가 무르익어 이에 대한 활발한 논의가 계속되어 오고 있다. 이러한 전자파 잔향실을 이용하여 EMI 및 EMS 시험을 실시할 수 있는 방법을 규격화시키자는 제안이 '96년 프랑스 Mandelieu 국제 전자파 장해 특별위원회(CISPR:International Special Committee on Radio Interference)회의에서 검토된 후 '97년 일본 Yokosuka CISPR 회의에서 정식의제로 채택되었다. 이 안건에 대하여 대부분의 국가들이 제안 취지에 찬성하여 NWIP(New Work Item Proposal) 문서가 각국에서 회람되었다. 초기 전자파 잔향실은 전자파 장해 및 복사 내성 측정을 위한 대용시험 시설로서 1968년 미국 Mendes에 의해 전자파 차폐실 구조에 Stirrer를 이용하여 필드의 균일도를 확보할 수 있다는 전자파 잔향실 개념이 처음으로 제안되었다. 이후 이 분야의 연구는 미국 표준 기술 연구소(NIST: National Institute of Standard and Technology)등에서 연구가 활발히 진행되고 있으며, 국제 표준화 기구인 CISPR에서 전자파 장해 및 내성 시험을 위한 대용시험 시설로서 활용하기 위하여 규격 작업이 진행중에 있다. 또한 최근 전자파 장해 방지를 위한 규제 주파수가 1∼18㎓ 까지 확장됨에 따라 이 주파수 대역에서 시험장으로 활용할 수 있는 전자파 잔향실이 새롭게 부각되고 있다. 전자파 잔향실은 기본적으로 공진 모드를 활용하기 때문에 일정한 크기의 잔향실 내부에서 전자파 균일성을 확보할 수 있는 모드 수에 의해 하한 주파수가 결정되며 충분한 모드 분포상태에서 Stirrer를 사용하여 필드 경계를 이동시킴으로서 확률적으로 균일한 필드분포를 확보하게 된다. 주파수가 증가함에 따라 모드수는 증가하기 때문에 하한 주파수 이상의 대역에 대한 시험시설로 활용할 수 있으며, 특히 ㎓ 대역에서 사용하기에 적합한 대용시험시설이라고 볼 수 있다.

Field Uniformity Analysis of Reverberation Chamber with Asymmetric Structure (비대칭적 구조 전자파 잔향실 전자기장 균일도 해석)

  • 정삼영;이중근;이황재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.837-843
    • /
    • 2001
  • Conventional reverberation chamber has a rectangular structure including mode stirrers or mode-turned stirrers to obtain the field uniformity inside the chamber. This paper explained the way to improve the field uniformity in an asymmetric structure instead of conventional rectangular structure with right-angled planes. Two types of asymmetric structure were considered. One was an asymmetric reverberation chamber using Quadratic Residue Diffuser and the other was an asymmetric chamber with oblique enclosure including fixed Randomly Made Diffusers. The FDTD simulation method was used to analyze the field homogeneous characteristics of these asymmetric reverberation chambers.

  • PDF

The Characteristics of Field & Mode Distributions in a Cylindrical Reverberation Chamber (원통형 구조 전자파 잔향실 내 모드 및 필드 분포 특성)

  • 김정훈;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.431-436
    • /
    • 2003
  • In this paper, simulation results of an electromagnetic field and mode distributions in a cylindrical reverberation chamber were presented. Reverberation chamber is an alternative test facility for a semi anechoic chamber, which is widely used for the analysis and measurement of electromagnetic interference and immunity tests. The method of computing the number of modes in a cylindrical reverberation chamber was presented and the number of modes in a cylindrical reverberation chamber with the same volume was compared with the different ratio of radius to height. The FDTD method was used to produce field characteristics inside of rectangular, right-angled isosceles triangular, and cylinder type reverberation chambers with the same test volume.

Expansion of Test Frequency Band and Improvements of Field Uniformity in a Reverberation Chamber by Using Dual-Band Diffusers (이중 대역 확산기를 이용한 전자파 잔향실 시험 주파수 대역 확장 및 전자기장 균일도 향상에 관한 연구)

  • Lim Wook-Chae;Rhee Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.74-80
    • /
    • 2006
  • This paper presents the characteristics of electromagnetic field uniformity in a reverberation chamber that can be used alternatively for the analysis, test and evaluation of electromagnetic interference and immunity. The dual-band diffuser, which can be used at two different frequency bands in a reverberation chamber, is applied, and it is made of two different single-band Schroeder's Quadratic Residue Diffusers. The FDTD method is used to analyze the field characteristics. Compared with single-band diffuser, the dual-band diffuser shows the improvement in not only expansion of test frequency band but also in characteristics of the field uniformity, polarity, power efficiency, and tolerance. Therefore, the reverberation chamber with the dual-band diffuser is a better facility, for the analysis and measurement of electromagnetic interference and immunity, than the reverberation chamber with a single-band diffuser.

Field Distribution of the Reverberation Chamber with Flat Diffusers Composed of Multiple Dielectric Materials (다중 유전체로 구성된 평탄형 Diffuser가 부착된 잔향실 내의 전자기장 분포에 관한 연구)

  • Kim, Young-Ryoul;Kim, Hye-Kwang;Rhee, Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.471-477
    • /
    • 2007
  • This paper presents the characteristics of electromagnetic field uniformity in a reverberation chamber with flat diffusers composed of multiple dielectric materials that can be used as an alternative facility for the analysis, test and evaluation of electromagnetic interference and immunity. The field characteristics and the size of the test volume inside the reverberation chamber with the new diffuser of multiple dielectric materials are simulated and analyzed at $2.5{\sim}3$ GHz band. The FDTD method is used to analyze the field characteristics. The field uniformity, polarization characteristics and tolerance are improved by the new diffuser with smaller physical size. The reverberation chamber with flat diffusers composed of multiple dielectric materials shows better electromagnetic performance and larger test volume than normal chamber.

Calculation and Uncertainty Estimation of the Volume of Reverberation Chamber with Indeterminate Form (부정형 잔향실의 체적 산출과 체적 불착도 평가)

  • Suh, Jae-Gap;Suh, Sang-Joon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.8
    • /
    • pp.375-380
    • /
    • 2007
  • A reverberation chamber should be designed and constructed so as to satisfy its purposes and available space. However, it is somewhat difficult to meet the intended design requirements due to various errors from construction process. So, the post-construction measurement of its volume and surface areas is very essential to check the actual volume and volume uncertainty of a reverberation chamber These values should be carefully calculated and accurately estimated since they are used not only to evaluate the acoustic characteristics of building materials but also to calculate uncertainties for other acoustic characteristics. In this work, the method for the calculation and uncertainty estimation of the volume of a reverberation chamber is presented. To this end, the coordinates of all corners was measured with Total Station after construction. The results showed that the calculated volume of the measured reverberation chamber differs by 5 % from the design specification. The expanded volume uncertainty was also estimated to be about 2 % of the total calculated volume.