• Title/Summary/Keyword: 잔류시간분포

Search Result 93, Processing Time 0.022 seconds

Proposan and Analysis of DR(Distributed Reflector)-LD/EA(electro-absorption)­Modulator Integrated Device (분포반사기 레이저 다이오드와 광흡수 변조기가 집적된 소자의 제안 및 해석)

  • 권오기;심종인
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.333-341
    • /
    • 1998
  • The novel integrated device, 1.55 ${\mu}{\textrm}{m}$ DR-LD(distrbuted reflector laser diode) integrated EA-MOD (electro-absorption modulator) as light source, is proposed to improve the device yield and its operational performances. This device can be easily fabricated by the selective MOVPE technique and its fabrication processes are almost the same as the reported 1.55 ${\mu}{\textrm}{m}$ DFB-LD(distributed feedback laser diode) integrated EA-MOD except the asymmetric gratings. The static and dynamic properties are investigated simultaneously by solving the transfer matrix method for light propagation, the time-dependent rate equation for carrier change and schr$\"{o}$dinger equation for QCSE (Quantum-Confined Stark Effect). The performances of the proposed device such as output power, chirp, and extinction ratio are compared with those of DFB-LD integrated EA-MOD. Under 10Gb/s NRZ modulation, we obtain that DR-LD integrated EA-MOD. is 30% higher in output power on the on-state, about 50% lower in chirp, and slightly larger in extinction ratio than DFB-LD integrated EA-MOD.-MOD.

  • PDF

One-Dimensional Heat Transfer Model to Predict Temperature Distribution in Voided slabs subjected to fire (화재 시 중공슬래브의 온도분포 예측을 위한 1방향 열전달 모델)

  • Chung, Joo-Hong;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.60-67
    • /
    • 2019
  • In general, a reinforced concrete slabs are known to have a high fire resistance performance due to thermal properties of concrete materials. However, according to previous research, the thermal behavior of voided slabs is reported to be different from that of conventional RC solid slabs, and the differences seem to be caused by the air layer formed inside the voided slab. Therefore, it is difficult to estimate the temperature distribution of the voided slab under fire by using the existing methods that do not take into account the air layer inside the voided slab. In this study, a numerical analysis model was proposed to estimate the temperature distribution of voided slabs under fire, and evaluated. Heat transfer of slabs under fire is generally caused by conduction, convection and radiation, and time-dependent temperature changes of slab can be determined considering these phenomena. This study proposed a numerical method to estimate the temperature distribution of voided slabs under fire based on a finite difference method in which a cross-section of the slab is divided into a number of layers. This method is also developed to allow consideration of heat transfer through convection and radiation in air layer inside of slabs. In addition, the proposed model was also validated by comparison with the experimental results, and the results showed that the proposed model appropriately predicts the temperature distribution of voided slabs under fire.

Environmental Fate Tracking of Manure-borne NH3-N in Paddy Field Based on a Fugacity Model (Fugacity 모델에 기초한 논토양에서의 액비살포에 따른 암모니아성 질소 거동추적)

  • Kim, Mi-Sug;Kwak, Dong-Heui
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.3
    • /
    • pp.224-233
    • /
    • 2019
  • Nitrogen components in liquid manure can reduce safety and quality of environment harmfully. To minimize the environmental risks of manure, understanding fate of manure in environment is necessary. This study aimed at investigating applicability of a simplified Level III fugacity model for simulating $NH_3-N$ component to analyze environmental fate and transport of $NH_3-N$ in liquid manure and to provide basis for improving management of N in the liquid manure system and for minimizing the environmental impacts of N. The model simulation conducted for four environmental compartments (air, water, soil, and rice plants) during rice-cropping to trace $NH_3-N$ component and provided applicability of the Level III fugacity model in studying the environmental fate of $NH_3-N$ in manure. Most of $NH_3-N$ was found in water body and in rice plants depending upon the physicochemical properties and proper removal processes. For more precise model results, the model is needed to modify with the detailed removal processes in each compartment and to collect proper and accurate information for input parameters. Further study should be about simulations of various N-typed fertilizers to compare with the liquid manure based on a modified and relatively simplified Level III fugacity model.

Translocation of Polychlorinated Biphenyls in Carrot-Soil Systems (Polychlorinated Biphenyl의 작물-토양간 흡수 이행성)

  • Lim, Do-Hyung;Lim, Da-Som;Keum, Young-Soo
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.203-210
    • /
    • 2016
  • Polychlorinated biphenyls (PCBs) are ubiquitous environmental contaminants, found in the many environments. PCBs exerts various toxicological effects, including endocrine-disrupting activity. Most researches with these toxicants performed with soil matrix with mixtures of congeners, namely Aroclor, while the biological activities have been tested with animals. However, studies with pure congeners are limited. In this study, 5 congeners were synthesized and their fates (bioaccumulation, degradation, kinetics) were studied in carrot-soil system. The soil half-lives of biphenyl, PCB-1, PCB-3, PCB-77, and PCB-126 were 20.2, 16.0, 11.6, 46.5, 198.0 days, respectively. In general, the longer half-lives were observed with the higher hydrophoicity of PCBs. Times, required for maxium accumulation of PCBs in carrot (Tmax) were 10-20 days for most congeners and the concentrations were 0.4-2.6 mg/kg. The concentrations of PCBs in carrot were kept as constant after Tmax, except PCB-126. The concentration ratio between carrot and soil after 90 days of treatment were 1.7, 8.1, 1.9, 1.8, and 5.9 for biphenyl, PCB-1, PCB-3, PCB-77, and PCB-126. Because of the increase of biomass, the total residual amount of PCBs in carrots however, increased till the end of experiment. The portions of PCB-126 in carrot were 1.1% of the soil residues at 90 days after planting.

The characteristics of chloramine formation and decay with pH variation (pH 변화에 따른 클로라민 생성과 분해 특성)

  • 조관형;김평청;우달식;조영태
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • This study was conducted to investigate the characteristics of chloramination as a secondary disinfection in a drinking water distribution system. At the range from pH 6 to pH 8, monochloramine was predominant with a trace of dichloramine, and the free chlorine was detected after breakpoint. At $25^{\circ}C$, the breakpoints of pH 6, 7 and 8 appeared when the weight ratios of chlorine to ammonia nitrogen were 11:1, 9:1 and 10:1 respectively, and the peak points on the breakpoint curves at pH 6, 7 and 8 were in the Cl$_2$ / NH$_3$-N ratio of 9:1, 6:1 and 5:1 respectively. As pH increased from 6 to 8, maximum point of monochloramine on the breakpoint curve was moved from 7:1 to 5:1 in the weight ratio of chlorine to ammonia nitrogen. The maximum concentration of monochloramine was formed at the pH values of 7~8 and in the Cl$_2$ / NH$_3$-N ratio below 5:1. As the Cl$_2$/NH$_3$-N ratio increased and the pH lowered, chloramines decay proceeded at an increased rate, and residual chloramines lasted longer than the residual free chlorine. The monochloramine and the dichloramine were formed at pH 6, and then the dichloramine continued increasing with contact time.

Determination of volatile and residual iodine during the dissolution of spent nuclear fuel (사용 후 핵연료 용해 중 휘발 및 잔류 요오드 분석)

  • Kim, Jung Suk;Park, Soon Dal;Jeon, Young Shin;Ha, Young Keong;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.395-406
    • /
    • 2009
  • The determination of iodine in the spent nuclear fuel and the volatile behavior during its acid dissolution have been studied by NAA(neutron activation analysis) and electron probe microanalysis (EPMA). Simulated spent fuels (SIMFUELs) were dissolved in $HNO_3$(1+1) at $90^{\circ}C$ for 8 hours. The iodine remained in a dissolver solution after dissolution, and that condensed in dissolution apparatus and trapped in the adsorbent by volatilization during the dissolution were determined, respectively. The condensed iodine was recovered by the redistillation with $HNO_3$(1+1) after transfer of the dissolver solution. The iodines in the dissolver and redistilled solution were separated by solvent extraction followed by ion exchange or precipitation method and determined by RNAA (radiochemical neutron activation analysis). The ion exchange column and filtration kit used for the isolation of iodine, which were prepared with a polyethylene tube, were used as an insert in the pneumatic tube for neutron irradiation. The iodine volatilized during the dissolution of SIMFUELs was collected in a trapping tube containing Ag-silica gel (Ag-impregnated silica gel) adsorbent, and the distribution of iodine trapped in the adsorbents were determined by EPMA. The adsorbing characteristics shown with the SIMFUELs were compared with those shown with a real spent fuel from the nuclear power plant.

Physical Weathering Characteristics of Mica-Schist in Sinbuk Area, Chuncheon, Korea (춘천시 신북지역에 분포하는 운모편암의 물리적 풍화특성)

  • Woo, Ik;Han, Byeong-Hyeon
    • Economic and Environmental Geology
    • /
    • v.40 no.6
    • /
    • pp.771-784
    • /
    • 2007
  • This study shows the weathering characteristics of mica-schist affected by faulting and metamorphism through laboratory tests. Frozen-thaw test, which simulate the physical-chemical weathering processes in the laboratory, shows the important influence of foliation developed in mica-schist, resulting in $20{\sim}40%$ reduction of UCS according to weathering grade of rock. Slaking durability test was carried out for different weathering grade rock specimens and indicated that the specimens from fault area had a low durability index compared to other relatively fresh samples. XRD analysis allowed to estimate the dynamic evolution of mineral composition through wet-dry cycle in which the chlorite was the most important mineral leached out during slaking test. The creep test indicated that the main deformation produced along the foliation plane. The compacted clay minerals between discontinuity planes influence on the discontinuity shearing properties and result in a big difference between peak shear strength and residual strength. The results of laboratory tests on mica-schist show the possibility of a important deformation along the foliation plane or discontinuity.

Combustion Performance Tests of Fuel-Rich Gas Generator for Liquid Rocket Engine Using an Impinging Injector (충돌형 분사기 형태의 액체로켓엔진용 가스발생기 연소성능시험)

  • 한영민;김승한;문일윤;김홍집;김종규;설우석;이수용;권순탁;이창진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.10-17
    • /
    • 2004
  • The results of the combustion performance tests of gas generator which supplies hot gas into the turbine of turbo-pump for liquid rocket engine and uses LOx and kerosene as propellant are described. The gas generator consists of a injector head with F-O-F impinging injector, a water cooled combustion chamber, a gas torch igniter, a turbulence ring and an instrument ring. The effect of turbulence ring and combustion chamber length on performance of gas generator are investigated. The ignition and combustion at design point are stable and the pressure and gas temperature at gas generator exit meets the target. The turbulence ring installed at middle of chamber effectively mixes hot gas with cold gas and the effect of residence time of hot gas in gas generator on combustion efficiency is small. Test results show that the main parameter controlling the gas temperature at gas generator exit is overall O/F ratio.

Ground Subsidence Measurements of Noksan National Industrial Complex using C-band Multi-temporal SAR images (C-밴드 다중시기 SAR 위성 영상을 이용한 녹산국가산업단지 일대의 지반침하 관측)

  • Cho, Minji;Lee, Chang-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.2
    • /
    • pp.161-172
    • /
    • 2014
  • Established in the lower reaches of the Nakdong river in Busan, the Noksan national industrial complex is one of the deepest soft ground areas in Korea. In case of the costal landfill having deep soft ground, there is a significant residual settlement over a long period of time. In this study, there was observed ground subsidence occurred in the Noksan national industrial complex from September 2002 to April 2007 by applying DInSAR and SBAS time series method using RADARSAT-1 and Envisat SAR datasets. As a result, it was calculated that ground subsidence developed at the velocity of about maximum 10 cm/yr and mean 6 cm/yr at the eastern center, west, western center and southern area contiguous on the coastline of the study area during the period from September 2002 to April 2007. In addition, the RADARSAT-1 average displacement map has been compared with the total displacement map observed by accurate magnetic probe extensometer during the period from 2001 to 2002. Since the time series displacement has shown a linear trend mostly, we consider that continuous monitoring should be needed until the ground subsidence of the study area has been stabilized.

Kinetics of the Low-temperature Pyrolysis of Mixed Plastics in the Batch Reactor (회분식반응기에서의 혼합 플라스틱의 저온열분해 kinetics)

  • Cha, Wang Seog;Oh, Myung Seog;Jang, Hyun Tae;Tae, Beomseok
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.540-544
    • /
    • 2008
  • Pyrolytic characteristics of mixed plastics containing 22 wt.% HDPE, 17 wt.% LDPE, 27 wt.% PP, 12 wt.% PS, 16 wt.% ABS, 6 wt.% PVC have been studied in the batch-type microreactor of stainless steel. Thermal degradation experiments were performed at temperature of $410{\sim}450^{\circ}C$. The yield of each pyrolytic products were obtained by the weight measurement and molecular weight distribution of pyrolytic liquid products determined by the GC-SIMDIS method. It was shown that the yield and molecular weight of pyrolytic liquid product were decreased with the increase of reaction temperature and time. It was know that 20wt% of PVC composing of the mixed plastics was converted to the gas products of chloride during the pyrolysis process. The chain-end scission rate parameter was determined to be 50.2 kcal/mole of mixed plastics by the Arrhenius plot.