• Title/Summary/Keyword: 작동기 배치

Search Result 19, Processing Time 0.024 seconds

New Mount with Moving-Coil-Type Electromagnetic Actuator for Naval Shipboard Equipment (가동코일형 전자기식 작동기를 결합한 함정 탑재장비용 마운트 개발)

  • Shin, Y.H.;Moon, S.J.;Jung, W.J.;Jeon, J.J.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.10
    • /
    • pp.885-894
    • /
    • 2013
  • In this study, a new hybrid mount with a moving-coil-type electromagnetic actuator is developed to reduce the vibration transmitted from naval shipboard equipment to the ship hull structure. The detailed design of the hybrid mount is determined through several design stages with electromagnetic numerical analysis using Maxwell software. The hybrid mount, which combines a rubber mount with an electromagnetic actuator, has a fail-safe function for shock resistance. The mount is fabricated and tested using a universal testing machine to check the design specifications. Finally, control tests are carried out on the hybrid mount to confirm its performance and applicability.

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

Development of SOFC stack module (SOFC 모듈평가장치 기술개발)

  • Choi, YoungJae;Lee, InSung;Jun, JoongHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.81.2-81.2
    • /
    • 2010
  • 고체 산화물 연료전지(SOFC) 시스템은 스택과 기계적 주변 장치인 MBOP(Mechanical Balance of Plant), 그리고 전기적 주변장치인 EBOP(Electrical Balance of Plant)로 구성되어있다. SOFC는 일반적으로 $700^{\circ}C$ 이상의 고온에서 작동되기 때문에 효율적인 열 이용 및 열 관리가 중요하다. SOFC 시스템의 MBOP에는 상온의 연료가스들을 고온으로 가열하여 스택에 유입 시기키 위한 열교환기 및 촉매연소기 등의 장치들이 필요하며, 효율적인 열관리를 위해서는 고온에서 작동하는 장치들을 한곳에 통합하여 구성하는 것이 필수적이다. 본 연구에서는 SOFC 시스템의 MBOP(Mechanical Balance of Pant) 중 고온부에 해당하는 촉매연소기, 열교환기 및 스택이 통합된 스택 모듈을 제작에 앞서 개념 검증을 위해 열교환기 및 촉매연소기로 이루어진 프로토타입(prototype)의 SOFC 모듈평가 장치를 제작하였다. 열교환기는 Plate형으로 총 6개로 구성되어 있으며, 연료극과 공기극 가스라인에 각각 3개씩 배치하여 스택에 유입되는 연료 및 공기가 촉매연소기에서 나오는 고온의 배가스와 열교환되어 가열되도록 구성하였다. 촉매연소기는 honeycomb 타입의 촉매를 사용하였고, 촉매연소기로 유입되는 연료극 배가스와 공기의 균일혼합과 hot spot을 방지하기 위한 장치를 삽입하여 제작하였다. 제작된 SOFC 모듈평가장치는 시운전을 통해 각 장치의 성능 확인 후 반응면적이 $20{\times}20cm^2$ 인 단전지를 적층하여 연계 운전을 수행하였다.

  • PDF

Experimental Analysis of Operating Parameters for Piezoelectric Jetting Dispenser (압전 젯팅 디스펜서의 작동 변수에 대한 실험적 분석)

  • Sohn, Jung Woo;Hong, Seung-Min;Kim, Gi-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.10
    • /
    • pp.685-691
    • /
    • 2015
  • In this work, to identify effective parameter for performance of piezoelectric jetting dispenser, experimental investigation is carried out based on design of experiment. After preparing jetting dispenser using two stack-type piezoelectric actuators, basic working principle of the jetting dispenser is described. Eight operating conditions are chose as main factors and it is assumed that each factor has two levels. To reduce number of experiments for performance evaluation, the experimental sets are designed based on factional factorial design method. Experimental setup is established and the weight of single dot is measured by using precision scale. The main and interaction effects of factors are analyzed using commercial statistical program and optimal operating condition for small amount and small variation of weight of dispensed single dot are determined.

Application and Performance Evaluation of Helicopter Active Vibration Control System for Surion (헬리콥터 능동진동제어시스템의 수리온 적용 및 성능 분석)

  • Kim, Do-Hyung;Kim, Tae-Joo;Paek, Seung-Kil;Kwak, Dong-Il;Jung, Se-Un
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.6
    • /
    • pp.557-567
    • /
    • 2015
  • The most decisive factor of major sources of a helicopter is the main rotor system and the rotor-induced vibration is one of the technical challenges which should be resolved to ensure comfort for crews and passengers. Passive vibration reduction devices are adopted in conventional helicopters and several types of passive devices are also used in Surion. In recent years, foreign helicopter manufactures have increasingly applied the application of AVCS (active vibration control system) because of their superior performance with lower weight compared to passive device. In addition to weight reduction, AVCS has advantages maintaining its performance over aircraft configuration changes and flight condition changes. The technology demonstration program was performed in order to validate the performance of AVCS when applied to Surion, and optimization process for finding optimal configuration of sensors and actuators. Optimal configuration was produced using ground and flight test data, and its performance was evaluated and compared with flight test result.

크라이오 펌프용 2단 GM형 맥동관 냉동기 개발

  • Go, Jun-Seok;Park, Seong-Je;Go, Deuk-Yong;Kim, Hyo-Bong;Hong, Yong-Ju;Yeom, Han-Gil;Kim, Yu-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.11-11
    • /
    • 2010
  • 고도의 진공 환경을 요구하는 반도체 생산 라인에 적용되는 고진공 펌프는 주로 복합 분자펌프와 크라이오 펌프가 사용되고 있다. 이 중 크라이오 펌프는 극저온으로 냉각되는 냉각판에 기체 분자를 응축 또는 흡착시켜 기체를 제거하는 방식으로 복합 분자 펌프로 무게가 가볍고 증발 온도가 낮은 네온, 수소, 헬륨 기체 제거에 장점이 있다. 본 연구에서는 현재 상용화된 크라이오 펌프에 적용되는 GM 극저온 냉동기를 대체하기 위한 2단 GM형 맥동관 냉동기를 개발하여 기초 성능 시험을 수행하였다. 1단과 2단 모두 U-자형 형상으로 제작되었으며, 압력과 질량 유동 사이의 위상 조절을 위하여 오리피스 밸브와 이중 유입 밸브를 사용하였다. 개발된 맥동관 냉동기의 냉각 성능 목표는 1단(80 K)과 2단(20 K)에서 각각 45 W와 5 W이다. 기초 시험에서는 위상 조절용 밸브들의 개도와 작동 조건에 대한 냉각 특성과 부하 특성 시험을 수행하였다. 특히, 본 연구에서는 로터리 밸브 및 위상 조절 기구의 배치로 인해 고온부 형상이 복잡한 맥동관 냉동기를 크라이오 펌프로의 적용 편의성을 위하여 고온부 외형 구조를 단순화하였으며, 개발된 맥동관 냉동기와 기존에 크라이오 펌프에 적용되는 GM 극저온 냉동기를 비교, 고찰하였다.

  • PDF

Study on Performance Variation According to the Arrangements of Adjacent Vertical-Axis Turbines for Tidal Current Energy Conversion (인접한 조류발전용 수직축 터빈의 배치방식에 따른 성능 변화)

  • Lee, Jeong-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.2
    • /
    • pp.151-158
    • /
    • 2016
  • Tidal farm is a multi-arrayed turbine system for utilizing tidal stream energy. For horizontal-axis turbine(HAT) system, it is recommended that each unit has to be deployed far apart in order to avoid hydrodynamic interference among turbines, as proposed by the European Marine Energy Centre(EMEC). But there is no rule for the arrangement of vertical-axis turbine(VAT) yet. Moreover it has been reported that a proper arrangement of adjacent turbines can enhance the overall efficiency even greater than an arrangement without mutual interference effect. This paper suggests the layout of VATs showing the better performances, which turned out to be quite different from HATs' arrangement. Numerical calculations were performed to investigate the performance variation in terms of the rotational direction as well as the distance between turbines. It has been shown that the best combination of rotational direction and distance between turbines can increase its performance higher about 9.2% than that of two independently operated turbines. It is likely that such improvement is due to the increased velocity between adjacent turbines. For diagonally arranged turbines, the maximum normalized mean power coefficient was obtained to be higher about 5.6% than that of two independent turbines. It is expected that the present results can be utilized for conceptual design of tidal farm to harness the tidal stream energy.

The Heat Transfer Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System (중온 태양열 축열조용 히트파이프의 열이송 성능)

  • Park, Min Kyu;Lee, Jung Ryun;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.69-69
    • /
    • 2011
  • 태양열 발전 플랜트에 사용되는 중고온 범위의 축열조에 고체-액체간 상변화를 수행하는 용융염을 축열물질로 사용하면 액체상 또는 고체상만으로 된 열저장 매체에 비해 축열조의 규모를 축소함과 동시에 축열온도의 균일성 향상에 기여할 수 있다. 중온인 $250{\sim}400^{\circ}C$ 범위에서 이용 가능한 용융염으로는 질산칼륨($KNO_3$), 질산리튬($LiNO_3$)등이 있다. 그러나 이러한 용융염의 가장 큰 단점은 열전도율이 매우 낮다는 것이며, 이로 인해 요구되는 열전달률을 성취하기 위해서는 많은 열접촉면적이 필요하다는 것이다. 이러한 단점을 극복하는 방법을 도입하지 않고서는 축열시스템의 소규화를 성취하는데 큰 효과를 가져올 수 없다. 한편 열수송 성능이 탁월한 히트파이프를 사용하면 열원 및 열침과 축열물질 사이의 열전달 효율을 증가시켜 시스템의 성능 향상과 동시에 소규모화에 기여할 수 있다. 중온 범위 히트파이프의 작동유체로서 다우섬-A(Dowtherm-A)는 $150^{\circ}C$이상 $400^{\circ}C$까지의 범위에서 소수에 불과한 선택적 대안 중 하나이다. 따라서 본 연구에서는 용융염을 사용하는 중온 태양열축열조에 적용 가능한 다우섬-A 히트파이프의 성능을 파악하여 기술적 자료를 제시하고자 하였다. 열원으로는 고온 고압의 과열증기, 그리고 열침으로는 중온의 포화증기를 고려하였다. 용융염 축열조를 수직으로 관통하는 히트파이프는 하단부에서 열원 증기와 열교환 가능하며, 중앙부에서 축열물질과 열교환하고, 상단부에서는 중온 증기와 접촉할 수 있도록 배치하였다. 축열모드에서는 히트파이프의 하단부가 증발부로 작동하고, 중앙부가 응축부로 작동하여 용융염으로 열을 방출하면 용융염의 온도가 상승하고 용융점에 도달하면 액상으로의 상변화가 진행되면서 축열이 활성화된다. 축열모드에서 히트파이프의 상단부는 단열부로 작동한다. 방열과정에서는 히트파이프의 하단부가 단열된 상태이고, 중앙부는 용융염으로부터 열을 받아 증발부로 작동하며, 상단부는 중온 증기로 열을 방출하므로 응축부로 작동한다. 즉, 축열시스템의 작동모드에 따라 하나의 히트파이프에서 증발부, 응축부, 단열부의 위치가 변하게 된다. 특히, 히트파이프의 중앙 부분이 응축부에서 증발부로 전환될 때에도 작동이 보장되려면 내부 작동유체의 연속적인 재순환이 가능해야 하므로, 일반 히트파이프에서와는 달리 초기 작동액체의 충전량을 증발부 전체의 체적보다 더 많이 과충전해야 한다. 이러한 히트파이프의 성능 파악을 위한 실험에서 고려한 변수들은 열부하, 작동액체의 충전률, 작동온도 등이며, 열수송 성능의 지표로서는 유효열전도율과 열저항을 이용하였다. 중온범위에서 적정한 작동온도를 성취하기 위해 실험에서는 전압 조절기로 열부하를 조절하는 동시에 항온조로 응축부의 냉각수 입구 온도를 제어하였다. 하나의 히트파이프에 대해서 최대 1 kW까지의 열부하에서 냉각수 입구 온도를 $40^{\circ}C$에서 $80^{\circ}C$ 범위로 변화시키면 히트파이프 작동온도를 약 $250^{\circ}C$ 내외로 조절 가능하였다. 히트파이프 작동액체 충전률은 윅구조물의 공극 체적을 기준으로 372%에서 420%까지 변화 시켰다. 실험 결과를 토대로 열저항과 유효 열전도율을 각각 입력 열유속, 작동온도, 작동액체 충전률 등의 함수로 제시했다. 동일한 냉각수 온도에서는 충전률이 높을수록 히트파이프의 작동온도가 감소하였다. 열저항 값의 범위는 최소 $0.12^{\circ}C/W$에서 최대 $0.15^{\circ}C/W$까지로 나타났으며 유효 열전도율의 값은 최소 $7,703W/m{\cdot}K$에서 최대 $8,890W/m{\cdot}K$까지 변화했다. 최소 열저항은 충전률 420%인 경우에 나타났는데 이때의 작동온도는 약 $262^{\circ}C$이었다. 히트파이프의 작동한계로서 드라이아웃(dry-out)은 충전률 372%의 경우에 열부하 950 W에서 발생하였으나, 그 이상의 충전률에서는 열부하 1060 W까지 작동한계 발생이 관찰되지 않았다. 실험 결과 본 연구에서의 히트파이프는 중온 태양열 축열조에 적용되어 개당 약 1 kW의 열부하를 이송하면서 축열물질 및 축방열 대상 유동매체와 열교환을 하는데 사용하는데 충분할 것이라 판단된다.

  • PDF

STUDY ON THE ATTITUDE CONTROL OF SPACECRAFT USING REACTION WHEELS (반작용휠을 이용한 위성체 자세제어 연구)

  • 두주영;최규홍;이상욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.1
    • /
    • pp.245-250
    • /
    • 1998
  • Attitude determination and control of satellite is important component which determines the accomplish satellite missions. In this study, attitude control using reaction wheels and momentum dumping of wheels are considered. Attitude control law is designed by Sliding control and LQR. Attitude maneuver control law is obtained by Shooting method. Wheels momentum dumping control law is designed by Bang-Bang control. Four reaction wheels are configurated for minimized the electric power consumption. Wheels control torque and magnetic moment of magnetic torquer are limited.

  • PDF

An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea (국내 랙크식 창고의 방화관련 규정 개선에 관한 연구)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.69-75
    • /
    • 2014
  • Recently Amore pacific rack-type warehouse fire broke out and argue an urgent improvement of fire protection design code including automatic sprinkler and detection design. Various type of commodities have their unique fire characteristics from fire spread rate and heat lease rate and fire hazard depends on storage height, rack arrangement, aisle width, fire load etc. With increasing ceiling height for more storage space prevent effective water spray of sprinkler head, also delays detection time causes failure of early suppression. To achieve fire protection code performance of this occupancy, Major code articles relating to a classification of commodity, sprinkler system installation, detection and fire fighting are reviewed and suggested based on fire case analysis, code review between country and field survey.