• Title/Summary/Keyword: 자장

Search Result 779, Processing Time 0.022 seconds

A study on the characteristics of axially magnetized capacitively coupled radio frequency plasma (축 방향으로 자화된 용량 결합형 RF 플라즈마의 특성 연구)

  • 이호준;태흥식;이정해;신경섭;황기웅
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.112-118
    • /
    • 2001
  • Magnetic field is commonly used in low temperature processing plasmas to enhance the performance of the plasma reactors. E$\times$B magnetron or surface multipole configuration is the most popular. However, the properties of capacitively coupled rf plasma confined by axial static magnetic field have rarely been studied. With these background, the effect of magnetic field on the characteristics of capacitively coupled 13.56 MHz/40 KHz argon plasma was studied, Ion saturation current, electron temperature and plasma potential were measured by Langmuir probe and emissive probe. At low pressure region (~10 mTorr), ion current increases by a factor of 3-4 due to reduction of diffusion loss of charged particles to the wall. Electron temperature slightly increases with magnetic field for 13.56 MHz discharge. However, for 40 KHz discharge, electron temperature decreased from 1.8 eV to 0.8 eV with magnetic field. It was observed that the magnetic field induces large temporal variation of the plasma potential. Particle in cell simulation was performed to examine the behaviors of the space potential. Experimental and simulation results agreed qualitatively.

  • PDF

A Study on the Characterisitics of Reactive Ion Etching (Cylindrical Magnetron을 사용한 실리콘의 반응성 이온 건식식각의 특성에 관한 연구)

  • Yeom, Geun-Yeong
    • Korean Journal of Materials Research
    • /
    • v.3 no.4
    • /
    • pp.327-335
    • /
    • 1993
  • Using a RF cylindrical magnetron operated with two electromagnets having a Helmholz configuration, RF magnetron plasma properties and characteristics of reactive ion ething of Si were investigated as a function of applied magnetic field strengths using 3mTorr $CF_4/H_2$ and $CHF_3$. Also, I-V characteristics of Schottky diodes, which were made of silicons etched under different applied magnetic field strengths and gas environments, were measured to investigate the degree of radiation damage during the reactive ion etching. As the magnetic field strent;th increased, ion densities and radical densities of the plasmas were increased linearly, however, the dc self-bias voltages induced on the powered electrode, where the specimen are located, were decreased exponentially. Maximum etch rates, which were 5 times faster than that etched without applied magnetic filed, were obtained using near lOOGauss, and, under these conditions, little or no radiation damages on the etched silicons were found.

  • PDF

A Unified Gradient Shape on the Slice-Selection Axis for Flow Compensation (스핀에코 펄스 시퀀스의 슬라이스 선택방향에서 혈류 보상을 위한 통일 경사자장법 연구)

  • Pickup, Stephen;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.70-80
    • /
    • 2006
  • Spin echo gradient moment nulling pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. A new technique was introduced for flow compensation that minimized echo time and effectively suppresses unwanted echoes on the slice selection gradient axis in spin echo sequences. A unified gradient shape was used in all orders of flow compensation up to the third order. A dual-purpose gradient was applied for flow compensation and to reduce unwanted artifacts. The sequences were used to generate images of phantoms and/or human brains. This technique was especially good at reducing eddy currents and artifacts related to imperfection of the refocusing pulse. The developed sequences were found to have shorter echo times and better flow compensation in through-plane flow than those of the previous models that were used by other investigators.

  • PDF

Compensation of Magnetometer in the Navigation System for Unmanned Helicopter using an Electric Motor (전기모터를 사용한 소형 무인헬리콥터에 활용될 항법장치용 자장계의 보상)

  • Lee, Gilho;Jo, Sungbeom;Kim, Jungsung;Choi, Keeyoung;Kee, Changdon;Song, Yongkyu;Koo, Wheonjoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.11
    • /
    • pp.997-1003
    • /
    • 2012
  • GNSS and ARS are the most common sensors in low-end UAVs. However, these sensors are vulnerable to built-in errors and cannot measure the body heading independently. The GNSS/INS cannot fully compensate the IMU errors in initial alignment process and rectilinear flights. For an unmanned helicopter, a magnetometer can be more useful than any other sensors to obtain heading information. However, the electric motor which drives small helicopter UAV keeps the magnetometer from reading the pure magnetotelluric vector. This paper shows the effects of electric motor on the magnetometer readings, and presents a method to compensate the effects. The results are verified with flight test data. The simulation and experimental results in this paper proves that aiding GNSS/INS with magnetometer increases observability and improves accuracy.

Parameters of the Magnetic Field Waveform Radiated from Cloud Lightning Discharges (운방전에 의해서 방사된 자장 파형의 파라미터)

  • 이복희;안창환;장석훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.917-926
    • /
    • 1999
  • In this paper, the recording device for measuring the magnetic field waveforms associated with the cloud lightning discharges was made by the loop-type magnetic field sensor, and the measuring system of a distance between lightning stroke point and observatory site was proposed. The parameters including the time interval of superimposed pulses, zero-to-zero crossing time and the percentage depth of the dip for the positive and the negative magnetic field waveforms were statistically analyzed as a function of the distance between the lightning discharge point and the observatory site. The results could be summarized as follows; Several superimposed pulses were observed at the initial front part of the magnetic field waveform produced by cloud lightning discharges, and the mean time interval between superimposed pulses was about $4\mu\textrm{s}$. Also, the bipolar characteristic appeared significantly and the percentage depth of the dip was about 57~65%. It was known that the zero-to-zero crossing time of the electromagnetic fields is gradually decreased as a distance between lightning discharge point and observatory site is increased.

  • PDF

Magnetic Sensitivity Depending on Width of IrMn Spin Valve Film Device (IrMn 스핀밸브 박막소자의 폭 크기에 의존하는 자장감응도)

  • Choi, Jong-Gu;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.41-44
    • /
    • 2010
  • The Cu thickness dependence of magnetic sensitivity for the NiFe/Cu/NiFe/IrMn spin valve multilayer was investigated. The magnetic properties measured by minor MR curves for the Ta(5 nm)/NiFe(8 nm)/Cu(3.5 nm)/NiFe(4 nm)/IrMn(8 nm)/Ta(2.5 nm) multilayer is MR = 1.46 %, MS = 2.0 %/Oe, $H_c\;=\;2.6\;Oe$, and $H_{int}\;=\;0.1\;Oe$. The magnetic sensitivities of GMR-SV devices with ten different widths and a same length of $4.45\;{\mu}m$ by fabricated by photo lithography decreased from 0.3 %/Oe to 0.06%/Oe as from a width of $10\;{\mu}m$ to $1\;{\mu}m$.

Formation of Induced Anisotropy in Amorphous Sm-Fe Based Alloy Thin Films (비정질 Sm-Fe계 합금 박막의 유도자기이방성 형성)

  • 송상훈;이덕열;한석희;김희중;임상호
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.261-269
    • /
    • 1998
  • Induced anisotropy with the energy of $6{\times}10^4\; J/m^3$ is obtained in amorphous Sm-Fe based thin films which are fabricated by rf magnetron sputtering under a magnetic field of 500~600 Oe. Compared with conventional thin films, the anisotropic thin films exhibit a similar "saturation" magnetostriction, but show a very large anisotropy in magnetorstiction which is of significant practical importance due to increased strain at a particular direction. It is shown from a systematic investigation over a wide composition range for binary Sm-Fe alloys that anisotropy is also induced, though small, during a normal sputtering procedure due to the stray field, and the largest anisotropy is observed in the composition range of 25~30 at.% Sm. Furthermore, induced anisotropy is also found to be formed by magnetic annealing, but the anisotropy energy is much smaller than that by magnetic sputtering. This may be because the volume diffusion by which atoms move during magnetic annealing to from induced anisotropy is much slower than the surface diffusion which is expected to be a dominant factor during magnetic sputtering.puttering.

  • PDF

A study on the reproducibility of hippocampal volumes measured using magnetic resonance images of different magnetic field strengths and slice orientations (자장 세기와 스캔 방향이 다른 자기공명영상에서 측정된 해마 체적의 재현성 연구)

  • Choi, Yu Yong;Lee, Dong Hee;Lee, Sang Woong;Lee, Kun Ho;Kwon, Goo Rak
    • Smart Media Journal
    • /
    • v.5 no.1
    • /
    • pp.44-48
    • /
    • 2016
  • In a longitudinal neuroimaging study, the upgrades of a magnetic resonance imaging (MRI) scanner due to outdated hardwares and softwares make it difficult to maintain the same MRI conditions in the long-term research period. Particularly, high field MRI systems such 3T scanners become popular in recent years. However, it is still unclear whether an integrated analysis of 3T and 1.5T images is possible without consideration of the field strength. In this study, we evaluated the reproducibility of hippocampal volumes between brain images with different field strengths and slice orientations. 296 participants underwent both 3T and 1.5T MRI and both sagittal and axial scans for high resolution brain images, and their hippocampal volumes were measured using Freesurfer, a well-known software for neuroimaging analysis. Paired t-tests showed that the hippocampal volumes were significantly different between the image types. These results suggest that it is necessary to develop data analysis techniques for integrating diverse types of MRI images.

Design of a Reflector for Infrared Camera (열화상 카메라용 반사경 설계)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.1
    • /
    • pp.97-104
    • /
    • 2014
  • Recently infrared cameras have been widely used to diagnosis degradation status of the power substitution system. At the place of high magnetic field, however, electronic parts of infrared camera take a place problem that is not reasonable working due to high magnetic field. In this paper, technique of design for reflector is proposed to perform degradation diagnosis without damage of infrared camera in a power substation system including the rectifier that is able to impact to the infrared camera by high magnetic field.

Fabrication technology and application of $Nb_3Sn$ superconductor for high magnetic field (고 자장용 $Nb_3Sn$ 초전도체의 제조기술 및 응용)

  • 오상수;류강식
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.518-525
    • /
    • 1995
  • 본 고에서는 Nb$_{3}$Sn 초전도선재의 대표적인 제조방법 및 원리 그리고 고자장마그네트 설계시 중요한 요소인 Nb$_{3}$Sn의 자장중 초전도특성 및 기계적특성 등에 대하여 고찰하고자 한다. 또한 Nb$_{3}$Sn 초전도선재의 응용분야로서 몇가지 대표적인 예를 들어 현재 세계적으로 활발하게 진행되고 있는 선진국의 고자장 초전도마그네트와 관련된 연구개발동향을 소개하고자 한다.

  • PDF