• Title/Summary/Keyword: 자장

Search Result 779, Processing Time 0.029 seconds

The Effect of Magnetic Field on Enhancing the Anisotropy of Melt-spun Nd-Fe-Co(-Zr)-B Alloy (급속응고중 외부자장에 의한 Nd-Fe-Co(-Zr)-B계 합금의 자기이방성 향상)

  • Lee, U-Yeong;Choe, Seung-Deok;Yang, Chung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.3
    • /
    • pp.233-238
    • /
    • 1992
  • Melt-spun $Nd_{14}Fe_{76}Co_4B_6$ and $Nd_{10.5}Fe_{79}Co_2Zr_{1.5}B_7$ ribbons were prepared under an externally applied magnetic field. Magnetic properties in terms of anisotropy were evaluated by discussing the effect of textured structure of the ribbon samples as well as its powders. About 32 % increase in $(B{\cdot}H)_{max}$ and 18.8 % increase in $B_r$ were observed along the perpendicular direction of the ribbon plane which is more prominent for the Nd-Fe-Co-Zr-B than for the Nd-Fe-Co-B alloy. The enhancement of magnetic anisotropy was monitored by measuring the anisotropy constant of each alloy as a function of quenching rate of the ribbon. It was found that for the melt-spun ribbon quenched at slow rate(less than 7 m/s) the magnetic field effect was overwhelmed by the heat gradient effect through the ribbon thickness while the field effect was prominent at intermediate quenching rate (more than 7~11 m/s). The reproducible maximum energy product, $(B{\cdot}H)_{max}$=16.4 MGOe can be obtained from the Nd-Fe-Co-Zr-B alloy.

  • PDF

Soft Magnetic Property Depending on thickness of Free Layer in CoFe/Cu/CoFe/IrMn Spin Valve Film (CoFe/Cu/CoFe/IrMn 스핀밸브 박막의 자유층 두께 감소에 따른 연자성 자기저항 특성 연구)

  • Choi, Jong-Gu;Go, In-Suk;Gong, Yu-Mi;Kim, Min-Ho;Park, Young-Suk;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.2
    • /
    • pp.52-56
    • /
    • 2009
  • Interlayer coupling field, coercivity, magnetoresitance ratio, and magnetic sensitivity depending on the thickness of free CoFe layer for the CoFe/Cu/CoFe/IrMn multilayer are investigated. In case of CoFe layer of $30\;{\AA}$ thickness for the CoFe(t)/Cu($25\;{\AA}$)/CoFe($60\;{\AA}$)/IrMn($80\;{\AA}$) multilayer with ferromagnet/non-magnet/ferromagnet structure induced by IrMn layer, the lowest coercivity and the highest magnetic sensitivity, which is contained soft magnetic property, are observed. On the other side, in case of CoFe layer of $90\;{\AA}$ thickness, there are the highest coercivity and the lowest magnetic sensitivity. The fabricated CoFe($30\;{\AA}$)/Cu($25\;{\AA}$)/CoFe($60\;{\AA}$)]/IrMn($80\;{\AA}$) spin valve device with $2{\times}8{\mu}m^2$ patterning size are measured by two probe method, which is selected the sensing current as the longitudinal direction and the easy axis as the transversal direction. The measuring magntoresistance ratio and magnetic sensitivity of GMR-SV device having the soft magnetic property are 3.0% and 0.3%/Oe, respectively.

Magnetization Reversal Behavior of Submicron-sized Magnetic Films in Response to Sub-ns Longitudinal Field Pulses Along the Easy Axis (1 ns 이하의 자화 용이축 펄스 자기장에 의한 자성박막의 자화 반전 거동)

  • Lee, Jin-Won;Han, Yoon-Sung;Lee, Sang-Ho;Hong, Jong-Ill
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.5
    • /
    • pp.188-193
    • /
    • 2007
  • We simulated the magnetization reversal behavior of submicron-thickness magnetic films by applying pulses of sub-ns-long durations and amplitudes along the easy axis. The films were rectangular and elliptical $Ni_{80}Fe_{20}$, and their thickness was 2 nm and 4 nm. We observed different behaviors depending upon the shape and thickness of the films and found a normal non-switching in regions in which we expected complete switching after relaxation. In the elliptical film, the non-switching regions were found to be random and to be widely distributed throughout the switching map. The strong demagnetization field along the z-axis, the film thickness direction, is likely responsible for this abnormal behavior. In the rectangular film, the abnormal non-switching regions were less distributed than they were in the elliptical film due to edge domains resulting from the small $M_z$ or demagnetization field during the switching. Our simulation confirms that large demagnetization is detrimental to the ultra-fast magnetization reversal of magnetic ultra-thin films.

B1+ Homogenizaion over Whole Field of View in High Field MRI (고자장 MRI에서의 영상 영역에 대한 B1+ 균질성)

  • Kim, Hong-Joon;Son, Hyeok-Woo;Cho, Young-Ki;Yoo, Hyoung-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.96-100
    • /
    • 2012
  • In high static field magnetic resonance imaging(MRI) systems, $B_0$ fields of 7 T and 9.4 T, the impressed RF field shows larger inhomogeneity than in clinical MRI systems with B0 fields of 1.5 T and 3.0 T. In multi-channel RF coils, the magnitude and phase of the input to each coil element can be controlled independently to reduce the non-uniformity of the impressed RF $B_1^+$ field. The convex optimization technique has been used to obtain the optimum excitation parameters with iterative solutions for homogeneity in a selected ROI(Region of Interest). To demonstrate the technique, the multichannel transmission line coil was modeled together with a human head phantom at 400 MHz for the 9.4 T MRI system and $B_1^+$ fields are obtained. In this paper, all the optimized $B_1^+$ in each isolated ROIs are combined to achieve significantly improved homogeneity over the entire field of view. The simulation results for 9.4 T MRI systems are discussed in detail.

The study of Rolled Steel Process Wastewater by Superconducting High Gradient Magnetic Separation (초전도 마그네트를 이용한 고구배 자기분리 열연강판 폐수처리에 관한 연구)

  • Kim, Tea-Hyung;Ha, Dong-Woo;Oh, Sang-Soo;Kim, Ho-Sup;Ko, Rock-Kil;Kwon, Jun-Mo;Lee, Nam-Jin;Kim, Young-Hun;Kang, Chae-Hun;Ha, Tae-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.11-11
    • /
    • 2009
  • 종래의 산업폐수 처리기술로는 중금속 함유 폐수에 수용성의 금속염을 첨가하여 가성소다 혹은 소석회를 이용하여 pH를 조정하고 고분자 응집제를 첨가하여 금속의 수산화물을 생성시켜 이를 부상 혹은 침전시켜 Sludge화하여 제거하는 방법이 주로 사용되고 있다. 그 외 질소, 인, 유기물이 함유된 폐수의 경우에는 Biological Oxidation Techniques, 활성탄 흡착방식이 주로 채택되고 있다.[1-3] 이러한 폐수처리기술은 화학약품 사용량이 과다하고 이는 Sludge 생성량을 증대하고 2차 폐수처리가 필요로 하는 경우가 많고, 처리장이 면적이 넓어야 하고 대용량의 Sludge 제거창치가 필요하여 고비용의 처리공정으로 문제점을 가지고 있다.[2-3] 이에 본 연구에서는 이러한 기존 기술의 문제점을 보완할 수 있고 기존 기술로는 완벽하게 처리하기 곤란한 악성 폐수들에 대한 새로운 고도처리기술로 초전도 마그네트를 이용한 고구배 자기분리기술에 대한 기초연구를 하였다. 본 연구에서 사용한 고구배 자기분리 시스템은 무헬륨 전도냉각방식으로 자기분리를 위해 사용한 필터는 SUS 430 재질의 메쉬 형태로 제작하여 실험하였다. 또한, 자기분리 처리를 위한 전처리 공정으로는 응집제를 첨가하여 자기분리 효율을 높이고자 하였다. 자기분리 처리대상수로는 포항제철에 압연 강판에 사용되는 냉각수를 대상으로 자기분리 처리에 대한 효과를 실험하였다. 또한, 자기분리에 대한 특성을 평가하기 위해 강자성의 $Fe_3O_4$ 미세자성분말을 첨가하여 처리수내의 들어있는 유기물질에 대해 자기분리 자장 및 유속에 대한 처리효율을 미치는 영향을 조사하였다. 자기분리 처리는 1~6 Tesla에서 자기필터는 디스크 형태로 다층으로 연속적으로 적층하였으며, 처리유속은 1~4 l/min으로 하였다. 고농도인 처리폐수를 자가분리 인가 자장에 따라 처리하여 고농도에서는 70%, 저농도에서는 98 %까지 처리되었다. 또한, 자기분리용 필터는 SUS 430 재질의 mesh 망을 사용하였으며 인가자장 및 유속변화에 대한 실험 결과 탁도 및 농도는 필터 크기의 영향은 거의 차이가 없었으며 단지 인가자장 및 유속에 따라서 지수적으로 감소하였다. 자기분리된 용액 내 $Fe_3O_4$ 입도 분석 결과 자기분리 이전에 분포하던 $10\sim20\;{\mu}m$의 입자는 거의 제거되었으며 2 ${\mu}m$ 이하의 입자들은 실험 횟수에 따라 점점 직경이 작은 쪽으로 분포가 좁아졌으며, 마그네타이트의 자화율을 분석한 결과 약 0.8 Tesla에서 포화 되었으며 처리수의 탁도 및 농도가 자장에 따라 감소하는 것으 알 수 있었다.

  • PDF

The Noise Performance of Diffusion Tensor Image with Different Gradient Schemes (확산 텐서 영상에서 확산 경사자장의 방향수에 따른 잡음 분석)

  • Lee Young-Joo;Chang Yongmin;Kim Yong-Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.439-445
    • /
    • 2004
  • Diffusion tensor image(DTI) exploits the random diffusional motion of water molecules. This method is useful for the characterization of the architecture of tissues. In some tissues, such as muscle or cerebral white matter, cellular arrangement shows a strongly preferred direction of water diffusion, i.e., the diffusion is anisotropic. The degree of anisotropy is often represented using diffusion anisotropy indices (relative anisotropy(RA), fractional anisotropy(FA), volume ratio(VR)). In this study, FA images were obtained using different gradient schemes(N=6, 11, 23, 35. 47). Mean values and the standard deviations of FA were then measured at several anatomic locations for each scheme. The results showed that both mean values and the standard deviations of FA were decreased as the number of gradient directions were increased. Also, the standard error of ADC measurement decreased as the number of diffusion gradient directions increased. In conclusion, different gradient schemes showed a significantly different noise performance and the schem with more gradient directions clearly improved the quality of the FA images. But considering acquisition time of image and standard deviation of FA, 23 gradient directions is clinically optimal.

A Study on the Recovery of a Metalic Fe-particle from the Steelmaking E.A.F. Slag by the Magnetic Separation (전기로 제강 슬래그에서 자력선별에 의한 지금의 회수)

  • 현종영;김형석;신강호;조동성
    • Resources Recycling
    • /
    • v.6 no.3
    • /
    • pp.3-8
    • /
    • 1997
  • The EA.F. sleelmaking slag (slag that follow) of a cnmvany 1 Co.. containzd a simple substance of a metal, wustlte (FeO), magnetite (Fe,O,), gehlenite (CaAl,SiO,), monlicellite (CaMgSiO,), dc. To recovere a metal (Fe grade . t95%) in the slag, it is desirable that the particles of a metal are isolated from thc slag and madc for a liberated subslance. Then, the liberaled melal is easlly recoveled by a magnetic separation. If thc rcclarnalcd slag, the sizc of which ranges under 40 nun, have a mulli-stage crushing, the most of a metal in thc slag is simply isolaled as a liberated subslance. If the mad, lhat is a liberated subslance and a sphere, is recovered by a magnetic field intensity. the minimum intensity, at which a metal is attracted, is approximately IOOG and did no1 dcpcnd on the particle size of a metad in the same particles. TIe recovered material. that contdined a iron (Fe) over 95% is a metal which is crushed slag by l00G in the multi-stage. If the magnetic field intcns~ty increase, the recovery mcrcasc, but the concentration grade decrease Bewusc thc concentration eams more and more impurities, iron oxide and the coml~ound of alkali earth element. 'll~ercforc If the rccla~nated slag have the multi-stage crushing, the metal is almostly recovered in the crushed slag by lO0G on each particles. If the slag, used as a rcclamatian lhat is a amount of 350,000 tan from I Co., was undcr the multistage crushing and then separaled by 100gauss, it is possible to recova a metal approximately 2.500 Ion, lhat is 0.73% of n ~eclamated slag. in 304.7 mm particles and to recover 4.200 tan in 0.3-1.7 mm particles , that is 1.2% nf a rcclamated slag, in a year. Therefore, ihe told recoverable meld is 6,700 ton, that is 19% of a reclmated slag, in a year, too.

  • PDF

Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom (두정부 백질 물질을 이용한 수소 자기 공명 분광 분석)

  • Lee, Jae-Yeong;Lim, Cheong-Hwan;Kim, Myeong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.57-61
    • /
    • 2003
  • The purpose of this study is to compare both 1.5T and 4.7T in Praietal White matter material Phantom using the same methodology at both field strengths. Data at both field strengths are compared in terms of $T_2$ relaxation times, line widths and SNRs MR imaging and $^1H$ MR spectroscopy were performed on GE 1.5T SIGNA system and Broker Biospec 4.7T/30 MRI/MRS system. After phantom axial scan $^1H$ MRS was obtained from T2 weighted image by 3-dimensional localization technique(PRESS : Point RE solved spectroscopy Sequence) this phantom is composed of an aqueous solution 36.7 mmol/L of NAA, 25.0 mmol/L of Cr, 6.3 mmol/L of choline chloride, 30.0 mmol/L or Glu, and 22.5 mmol/L of MI(adjusted to a pH of 7,15 in a phosphate buffet). Data processed using software developed inhouse. At 1.5T, T2 relaxation times for Cho, Cr, and NAA were $0.41{\pm}0.07,\;0.26{\pm}0.04,\;0.46{\pm}0.07$ while at 4.7T they were $0.17{\pm}0.03,\;0.14{\pm}0.05,\;0.20{\pm}0.03$ respectively. At 1.5T, line widths for water, Cho, Cr and NAA were $2.9{\pm}0.7,\;1.6{\pm}0.7,\;1.7{\pm}0.8,\;2.2{\pm}0.02Hz$ while at 4.7T they were $5.2{\pm}1.1,\;4.6{\pm}1.9,\;4.01{\pm}1.8,\;4.8{\pm}1.9Hz$ respectively. It can be seen that $T_2$ relaxation times were significantly shorter at 4.7 compared to 1.5T and that the line widths were also broader. The average SNRs for NAA for subjects at short and long TEs were $23.5{\pm}11.3$ at TE=20 msec ; $15.4{\pm}7.7$ at TE=272 msec at 1.5T and $40{\pm}8.3$ and $17{\pm}3.5$ respectively at 4.7T higher field strength is superior because of improved sensitivity and chemical shift dispersion. However these improvements are partially offset by increased line widths and decrease $T_2$ relaxation times, which act to reduce both sensitivity and resolution. In our experiments with the equipment available to us, 4.7T proton spectra at short TEs exhibit moderately improved sensitivity compared to 1.5T.

  • PDF

Anisotropy Measurement and Fiber Tracking of the White Matter by Using Diffusion Tensor MR Imaging: Influence of the Number of Diffusion-Sensitizing Gradient Direction (확산텐서 MR 영상을 이용한 백질의 비등방성 측정 및 백질섬유 트래킹: 확산경사자장의 방향수가 미치는 영향)

  • Jun, Woo-Sun;Hong, Sung-Woo;Lee, Jong-Sea;Kim, Sung-Hyun;Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • Purpose : Recent development of diffusion tensor imaging enables the evaluation of the microstructural characteristics of the brain white matter. However, optimal imaging parameters for diffusion tensor imaging, particularly concerning the number of diffusion gradient direction, have not been studied thoroughly yet. The purpose of this study was to evaluate the influence of the number of diffusion gradient direction on the fiber tracking of the white matter. Materials and methods : 13 healthy volunteers (ten men and three women, mean age 30 years, age range 23-37 years) were included in this study. Diffusion tensor imaging was performed with different numbers of diffusion gradient direction as 6, 15, and 32, keeping the other imaging parameters constant. The imaging field ranged from 1 cm below the pons to 2-3 cm above the lateral ventricle, parallel to the anterior commissure-posterior commissure line. FA (fractional anisotropy) maps were created via image postprocessing, and then FA and its standard deviation were calculated in the genu and the splenium of the corpus callosum on each of FA maps. Fiber tracking of the corticospinal tract in the brain was performed and the number of the reconstructed fibers of the tract was measured. FA, standard deviation of FA and the number of the reconstructed fibers were compared statistically between the different diffusion gradient directions. Results : FA is not statistically significantly different between the different diffusion gradient directions. By increasing the number of diffusion gradient direction, standard deviation of FA decreased significantly, and the number of the reconstructed fibers increased significantly. Conclusion : The higher number of diffusion gradient direction provided better quality of fiber tracking.

  • PDF

Temperature Changes during Freezing and Effect of Physicochemical Properties after Thawing on Meat by Air Blast and Magnetic Resonance Quick Freezing (식육의 송풍식 냉동과 전기자장 냉동 중 온도 변화 및 이화학적 품질에 미치는 영향)

  • Kim, Young Boong;Woo, Sung Min;Jeong, Ji Yun;Ku, Su Kyung;Jeong, Jin Woong;Kum, Jun Seok;Kim, Eun Mi
    • Food Science of Animal Resources
    • /
    • v.33 no.6
    • /
    • pp.763-771
    • /
    • 2013
  • This study was carried out to investigate the effects of various temperatures of electro-magnetic resonance and air blast freezing methods on the physicochemical quality of meat. Beef (loin and round), pork (belly and ham) and chicken (breast and leg) were purchased at a commercial market, and the meat was frozen using three methods: air blast freezing ($-20^{\circ}C$ and $-45^{\circ}C$) and electro-magnetic resonance quick freezing. Changes in the physicochemical properties of meat were analyzed by drip loss, cooking loss, water holding capacity (WHC) and proximate compositions. In comparison, regardless of the animal species and cuts of meat, electro-magnetic resonance quick freezing (2 h) resulted in a completely frozen product in a much shorter time than $-20^{\circ}C$ and $-45^{\circ}C$ air blast freezing (24 h and 8 h, respectively). Drip loss of loin which had underwent electro-magnetic resonance quick freezing were significantly (p<0.05) lower than those of the other two treatments, but cooking loss and water holding capacity were the highest at 43.7% and 60.7%, respectively (p<0.05). Characteristics such as crude protein, crude fat and moisture compositions showed significant differences, depending on the cuts and freezing methods (p<0.05). The fat composition of electro-magnetic resonance quick frozen loin and round were significantly low (p<0.05). However, moisture content was the highest compared to other freezing methods, as 67.1% and 71.9%, respectively (p<0.05). Electro-magnetic resonance quick freezing was an appropriate way to reduce the deterioration of meat quality due to freezing, and the drip loss was least for the part with low moisture, low protein, and high fat.