• Title/Summary/Keyword: 자장민감도

Search Result 16, Processing Time 0.016 seconds

Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by using Multi-Hall Devices (다중 홀소자를 이용한 맥진기의 3차원 파형 획득 연구)

  • Choi, S.D.;Kim, M.S.;Ahn, M.C.;Choi, Y.G.;Kim, G.W.;Park, D.H.;Hwang, D.G.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.4
    • /
    • pp.216-220
    • /
    • 2006
  • The electric signals for the voltage as a function of distance between Hall devices and permanent magnets over the radial artery were investigated. The electric sgnals, that means signals of arterial pulse wave, were differentiated by the hardware of circuits and then were changed to differential signals as magnetic field. The 3-D images simulated by the software as function fo the intensity of differential signals were achieved. It shows that these system can apply to pulse diagnostic apparatus of porthble type medical instrument.

A Study on the Magnetoresistive RAM (MRAM) Characteristics of NiFeCo/Cu/Co Trilayers (NiFeCo/Cu/Co 삼층막의 자기저항 메모리 특성에 관한 연구)

  • 김형준;이병일;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.3
    • /
    • pp.152-158
    • /
    • 1997
  • NiFeCo/ Cu /Co trilayers were formed on 4$^{\circ}$ tilt-cut Si(111) substrates with a Cu(50$\AA$) underlayer and large-scaled test magnetoresistive RAM (MRAM) cells were fabricated using a conventional lithographic process. NiFeCo / Cu /Co trilayers deposited on the same templates without any applied magnetic field showed strong in plane uniaxial magnetic anisotropy and excellent magnetoresistive (MR) properties such as high MR ration and sensitivity within a low external magnetic field, which are suitable properties for a MRAM application. In order to obtain optimized MR results in NiFeCo /Cu /Co trilayers, the thickness of Cu spacer was varied. Interlayer coupling between two magnetic layers was observed and it was found that the MR properties were strongly dependent on the coupling force, especially near 20 $\AA$ of Cu spacer thickness. Test MRAM cells were fabricated using the optimized NiFeCo (60$\AA$)/ Cu (25$\AA$)/ Co (30$\AA$) trilayer thin films. With a 10 mA of sense current and 5$\times$$10^5$ of word current, 10 mV of signal output was obtained, which implies the strong potentials of NiFeCo/ Cu /Co trilayer thin films for a MRAM application.

  • PDF

Magnetoresistance of Single-type and Dual-type GMR-SV Multilayer Thin Films with Top and Bottom IrMn Layer (상부와 하부 IrMn층을 갖는 단일구조 및 이중구조 거대자기저항-스핀밸브 다층박막의 자기적 특성 비교 분석)

  • Choi, Jong-Gu;Kim, Su-Hee;Choi, Sang-Heon;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.4
    • /
    • pp.115-122
    • /
    • 2017
  • The antiferromagnet IrMn based four different GMR-SV multilayers on Corning glass were prepared by using ion beam deposition and DC magnetron sputtering system. The magnetoresistance (MR) properties for single-type and dual-type GMR-SV multilayer films were investigated through the measured major and minor MR curves. The exchange bias coupling field ($H_{ex}$) and coercivity ($H_c$) of pinned layer, the $H_c$ and interlayer exchange coupling field ($H_{int}$) of free layer for the dual-type structure GMR-SV multilayer films consisted of top IrMn layer were 410 Oe, 60 Oe, 1.6 Oe, and 7.0 Oe, respectively. The minor MR curve of two free layers was performed the squarelike feature having a MR ratio of 8.7 % as the sum of 3.7 % and 5.0 %. The value of average magnetic field sensitivity (MS) was maintained at 2.0 %/Oe. Also, the magnetoresistance properties of the single-type and dual-type structure GMR-SV multilayer films consisted of bottom IrMn layer were decreased more than those of top IrMn layer. Two antiparallel states of magnetization spin arrays of the pinned and free layers in the dual-type GMR-SV multilayer films occurred the maximum MR value by the effect of spin dependence scattering.

The characteristics of nonlinear magneto-optical effect based on coherent population trapping in the D1 line of Rh atoms (87Rb D1 전이선에서 원자결맞음을 이용한 비선형 광자기 효과 신호의 특성)

  • Lee, L.;Moon, H.S.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • We investigated the characteristics of the nonlinear magneto-optic effect (NMOE) depend on the transitions, the laser intensity and the temperature of the vapor cell, in the $D_1$ transition of $^{87}Rb$ atoms by using the Rb vapor cell contained with buffer gas of Ne 6.7 kPa. The size and the width of NMOE signal were increased according to the light intensity and temperature in the transition of F=2$\to$F'=2. However, In the case of using the F=2$\to$F'=1 transition, the size of the signal could be increased according to the light intensity without additional broadening of the width. We confirmed that the sensitivity of detecting small magnetic flux improved in this transition, and explained these effects by the different of the CPT configuration between Zeeman sublevels. At the optimal condition in experiment, the sensitivity of this system was evaluated less then $70pT/\sqrt{Hz}$.

Effect of sputtering conditions on the exchange bias and giant magnetoresistance in Si/Ta/NiFe/CoFe/Cu/CoFe/FeMn/Ta spin valves (스파터링 조건이 FeMn계 top 스핀 밸브의 exchange bias 및 자기적 특성에 미치는 영향)

  • Kim, K.Y.;Shin, K.S.;Han, S.H.;Lim, S.H.;Kim, H.J.;Jang, S.H.;Kang, T.
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.2
    • /
    • pp.67-73
    • /
    • 2000
  • Top spin valve samples with a structure Ta/NiFe/CoFe/Cu/CoFe/FeMn/Ta were deposited on a Si(100) substrate by changing d.c. magnetron sputtering conditions and the exchange-bias and magnetic properties of samples were investigated. The Exchange field, H$\_$ex/ increased with increase of sputtering power of FeMn from 30 to 150 W and CoFe from 30 to 100 W deposited on the Cu, the increase of H$\_$ex/ was found due to the improvement of preferred orientation of (111) FeMn phase from XRD results. In the case of Cu, H$\_$ex/ decreased with the increase of sputtering pressure ranging from 1 to 5 mTorr. The relationship between exchange field and resistance was investigated, spin valve samples with a large exchange field showed the lower resistance, which was strongly dependent on the good crystallinity and grain size increase as well as lower scattering effects. The Cu thickness was changed from 22 to 38 $\AA$ for Si/Ta/NiFe/CoFe/Cu(t), 30 W/CoFe, 100 W/FeMn, 100 W/Ta spin valve structures, MR ratio of 6.5 % and exchange field of about 190 Oe were obtained for the sample with Cu of 22 $\AA$ thickness. The increase of exchange field with decrease of Cu thickness was explained by FM/AFM spin-spin interaction.

  • PDF

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF