• Title/Summary/Keyword: 자연채광시스템

Search Result 61, Processing Time 0.022 seconds

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

An Analysis on Development and Application of Solar Sunlighting Systems (첨단 태양광채광시스템의 개발현황 및 활용실태 분석에 관한 연구)

  • Kim, Jeong-Tai;Hwang, Min-Ku;Han, Bong-Soo
    • KIEAE Journal
    • /
    • v.2 no.1
    • /
    • pp.63-68
    • /
    • 2002
  • Solar sunlighting systems are useful to apply for most buildings. This study aims to analysis the development and architectural application of solar sunlighting systems. For the purpose, abroad developing situation of solar sunlighting systems were investigated and analyzed literally. And, by case studies, architectural application methods are analyzed. As results, light pipe systems are mainly used for small building and houses. Also solar mirror systems are used for atrium and underground spaces. Lens-fiber systems are applied for high rise buildings and office buildings which internally have no influx of sunlighting. Some application suggestion in our country are discussed.

An Experimental Study on Control Strategy of LED System Using Daylight (주광을 활용한 LED조명시스템의 컨트롤에 관한 실험적 연구)

  • Yun, Gyeong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.33-39
    • /
    • 2010
  • Visual Environment and productivity are correlated. So we need to create a comfortable visual environment and maintain proper workplane illumination level. We can obtain lighting energy savings and comfortable visual environment using daylight and LED lights. In this study, we characterized the indoor illuminance level according to the sky condition and proposed dimming control strategy of LED lights. Energy savings in On/Off control mode are 40% at clear sky and 28% at intermediate sky. In dimming control mode, energy savings are 77.2% at clear sky and 64.1% at intermediate sky. Then we obtain the appropriate dimming control strategy of LED lights based on data. Dimming rates are 0-14.2-80(min-avg-max, %) for LED 1, 0-19.9-60% for LED 2 and 30-61.4-90% for LED 3. Lighting energy savings are 68.2% for LED dimming system applied this control method.

Projecting Performance of a Daylighting Source Based on Its Architectura Applications in the Open-Top Surface Structure (고심도 공간의 건축적 특성에 따른 자연집광 시스템의 조명원적 성능분석)

  • Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A lightcourt design is typically used to address issues concerning aesthetics, feeling, and mood. From the view point of environmental aspect, as an ecological shaft space, it plays a key role in controlling inner quality. In particularly, the lightcourt concept allows the exploitation of daylighting by bring natural light into the center of the building, thus eliminating dark deep spaces. Additionally, the lightcourt shades the inner space in summer. The amount of light available at the base of the lightcourt depends on a number of factors; translucency of the top, reflectance and the geometry of the space. In this paper is to exemplify a lightcourt configuration with a sloped wall. It promises the maximized a sense of freedom and daylighting availability. It is a matter of course that the lightcourt with open-top plays a role as a light source for the adjacent space to the lightcourt. A series of lighting simulation provides performance data of daylighting with changing photometric factors. For the case that a skylight is not available, an electric lighting design with metal halide lamps has been established to create luminous ceiling. As expected, a sloped lightcourt with open-top exposes its superiority of daylighting source. Ancillary considerations to enhance of daylighting potential for the adjacent space have been issued with performance data.

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance (염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구)

  • Oh, Myung-Hwan;Sim, Se-Ra;Lee, Chul-Sung;Chin, Kyung-Il;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method (광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가)

  • Kim, Dong-Su;Yoon, Jong-Ho;Shin, Woo-Chul;Lee, Kwang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.

A Study on Evaluation of Daylighting in Office Space Applied BIPV Systems in Accordance with Power Performance (사무공간 적용 BIPV시스템의 자연채광 및 성능평가에 관한 연구)

  • Seo, Young-Seok;Oh, Min-Suk;Kim, Hway-Suh
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.148-154
    • /
    • 2009
  • By the skyscraper building, increase of skin area and expansion of curtain wall system will be the important factors of acceleration in extending supply of BIPV system. In the future interior environmental evaluation is not a necessary to the residents but an essential term which will bring enormous influence. In the interior environmental evaluation, natural light will let the residents with direct contact with outside circumstances and make them feel opened. also only the daylight has radiant energy and color rendering that will have a great influence to residents' mental, operation efficiency and advancing productivity. This research compares and analyzes BIPC system in office spaces with two general sunlight's module. In addition to natural light's efficiency for BIPC system's comfort and confirmed economical efficiency will be applied to basic research data. Hence forth, ensuring indoor intensity of illumination and controlling light system to reducing energy research data will be demanded to increase the amount of supplying BIPC system. Also continuance research in the possibility of applying BIPC system in various buildings, room temperature affected by location of windows and its condensation, and economical evaluation will be required.

  • PDF

Experiment on measures of heat collection for passive solar water wall systems that provide heat storage and natural lighting control (축열과 채광조절을 겸한 자연형 태양열 수벽시스템의 집열방식별 성능실험)

  • Oh, Young-hoon;Choi, Ji-eun;Lee, Chul-sung;Yoon, Jong-ho
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.63-69
    • /
    • 2016
  • Purpose: This preliminary study investigated a potential of the water wall systems that provide heat storage and natural lighting control simultaneously. Method: In order for transparency of the water wall to be controlled, the study first proposed two measures: to adjust transparency of the water wall; to control transparency of water wall surface. The performance of two measures then was verified and compared by experiments. In addition, a trade-off between heat collect and heat storage resulting from using additive for adjusting transparency was investigated. Result: The experiment showed that the two measures are similar in performance. The investigation of trade-off relation showed the additive should have the same heat storage as the water to prevent decrease in thermal performance of the water wall. As an economical measure to control transparency of the water wall, this study suggested a measure of secondary heat transfer systems using shading device that first absorbs solar radiation and then transfers heat to the water wall. The experiment show that performance of the proposed measure is similar to controlling transparency of water wall surface. In conclusion, it is expected that the performance of the water wall can be economically maximized by using the proposed mean in terms of heating, cooling and lighting energy saving.

Indoor Visual Environmental Estimate Experiment Evaluation of See Through BIPV Curtainwall System (가시성확보 BIPV 커튼월시스템의 실내 시환경 예측 시험 평가)

  • Cha, Kwangseok;Jo, Boram
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.108-108
    • /
    • 2011
  • 공동주택에서 2025년 정부가 추진하고 있는 Zero Energy 건축물 구현과 친환경에 대한 탄소배출 저감 문제로 재생에너지 생산시스템의 추가 적용은 반드시 필요하다. 따라서 공동주택 적용 및 활용성을 높일 수 있는 BIPV시스템 개발을 통하여 설치면적 확보와 세대 활용성을 높일 수 있도록 하는 것이 필요하다. 특히 거실 창호의 경우 주방향이 남향, 남동 또는 남서향으로 배치되어 태양광을 적용하기에 적합한 특성을 가지고 있다. 그러나 창호는 건물외피의 역할과 재실자가 조망과 정보취득을 얻을 수 있는 중요한 통로가 되기 때문에 단열 문제나 시야 차폐의 문제는 발생하지는 않도록 하는 것이 필요하다. 본 연구에서는 a-si타입 모듈 2개를 10% 투과율로 Bsck Coating 색상을 달리한 모듈과 c-si BIPV 모듈을 커튼월 창호시스템으로 개발, 일반 2중 창호시스템과 비교 평가를 위해 실제 Test bed 건물에 시공하여 시환경 및 실내 창측면 온도변화 측정 분석을 진행하였다. 현재 국내외 출시되고 있는 a-si see through 모듈은 10~30%의 투과율로 창 마감재로 대체가 가능하나 건축 환경(시환경,열환경)에 대한 분석은 전무한 상태이다. 본 연구에서는 시환경과 창유리면의 열 부하, 자외선, 적외선 차폐 및 가시광선의 투과율에 대한 평가와 Back Coating에 따른 색온도 평가를 통해서 a-si BIPV의 공동주택 세대 발코니 창호 적합성에 대한 검토를 진행하였다. 연구결과는 아래와 같다. ${\bullet}$ 실내조도는 청천공 정오기준 가시성 확보 모듈의 경우 2,300 ~ 3,500lx를 나타내고 있어 대비 현상이나 창측의 급격한 조도 변화가 적은 시환경 구축이 가능 ${\bullet}$ 12시경 휘도는 창측면, 실내 벽체, 코너 바닥면을 대상으로 a-si BIPV 모듈을 적용한 경우 휘도비가 12:1로 KS나 IESNA의 광원과 근접면의 비 20:1 범위에 모두 존재, 적합한 것으로 분석되었으나 c-si의 경우는 그림자로 인한 대비 현상이 발생, 작업 시환경 문제 발생. ${\bullet}$ 이중시스템 창호와 비교하여 단열 성능 떨어짐. 발전시간대 창유리 면 온도 상승 으로 하절기 냉방부하 증가. ${\bullet}$ 자외선은 100% 가까이 차단, 적외선은 13~42%만 투과되고 가시광선은 13% 투과율을 나타내어 일반 창에 칼라 코팅을 적용하는 것과 유사한 경향을 나타냄.

  • PDF