Development of solar powered water pump - Energy conversion test and performance analysis - (태양열을 동력원으로 한 물펌프 연구개발 - 에너지변환실험과 성능해석 -)

  • 김영복;이양근;이승규;김성태;정병섭
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.167-172
    • /
    • 2002
  • 본 연구에서는 자연에너지인 태양열을 이용하여 물 펌프를 구동할 목적으로 n-pentane을 작동물질로 하는 열에너지의 동력변환 실험을 수행하고 작동물질의 온도, 압력, 힘을 측정, 계산하고 분석하였으며, n-pentane을 이용하면 양정 10m 이상은 충분히 양수할 수 있는 것으로 판단되었다. 작동물질의 엑서지를 분석하여 작동물질의 작동온도범위를 결정하여 예상사이클선도를 결정하였고, 양수 량을 고정하였을 경우 사이클횟수와 하루의 양수량, 열효율을 계산하고 분석하였다.

  • PDF

Prediction of Minimum Spontaneous Ignition Temperature(MSIT) of the Mixture of n-Pentanol and Ethylbenzene (n-Pentanol과 Ethylbenzene 혼합물의 최소자연발화온도의 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.45-51
    • /
    • 2012
  • The MSITs(Minimum Spontaneous Ignition Temperatures) or AITs(Autoignition Temperatures) describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. This study measured the MSITs(Minimum Spontaneous Ignition Temperatures) of n-pentanol+ethylbenzene system by using ASTM E659 apparatus. The MSITs of pure n-pentanol and ethylbenzene were $285^{\circ}C$ and $475^{\circ}C$, respectively. The experimental MSITs of n-pentanol+ethylbenzene system were a in good agreement with the MSIT calculated by the proposed equations with a few A.A.D.(average absolute deviation).

Numerical Study on Enhanced Heat Conduction of Phase-Change Thermal Energy Storage Devices in The Presence of Natural Convection (자연대류 영향을 고려한 상변화 열에너지 저장장치의 열전도향상에 관한 수치적 연구)

  • Chung, Hong-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.207-212
    • /
    • 1993
  • Numerical inverstigation of heat transfer in phase-change energy storage devices was performed in order to aid In the design process for a finned Phase-Change Material( PCM). A simplified model based on a quasi-linear, transient, thin fin equation, which predicts the fraction of melted phase-change material, and the shape of liquid-solid interface as a function of time, is used. The model is solved by using Finite Volume Method(FVM), and the numerical results have showed good agreement with experimental data.

  • PDF

Impact Analysis of Discharging Water Temperature from Water Heat Energy System on Dwonstream of the River (방류수 수온이 하류 하천 수온변화에 미치는 영향 분석)

  • Nam, Jisu;Jung, Jaewon;Joo, Hongjun;Jung, Sungeun;Kim, Hung Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.131-131
    • /
    • 2018
  • 하천의 생태계는 다양한 이화학적 및 생물학적 요인들에 의해 많은 영향을 받으며 그 중 수온은 수질 및 수생태계에 지대한 영향을 미치는 인자라고 할 수 있다. 하천의 수온은 인간의 활동과 도시화에 의해 인위적인 교란을 받고 있다. 따라서 본 연구에서는 수온변화의 원인 중 자연에서 취수한 물에 인위적으로 열에너지를 첨가하여 수온이 높은 상태에서 다시 자연으로 방류하여 문제가 되고 있는 온배수에 초점을 맞춰 분석을 시행하고자 한다. 온배수는 하류 하천의 수질 및 그곳에 서식하는 생물들의 서식처와 같은 다양한 수환경에 직접적으로 변화를 발생시킬 수 있다. 따라서 하천 생태계의 보호를 위한 방류수 수온의 관리를 위해서는 변화된 수온의 영향 범위를 분석할 필요가 있다. 본 연구에서는 실제 방류되는 온배수의 평균 수온과 기존 하천 수온의 온도차를 이용해 물질수지식과 3차원 모형인 EFDC(Environmental Fluid Dynamics Code)를 활용하여 방류수로 인한 하류 하천의 수온 변화를 모의하고자 하였다. 또한 적절한 수온의 관리를 위해 방류수 수온 및 유량의 인자를 변화시켜가면서 하류하천의 수온변화 모의를 실시하고자 하였다. 본 연구의 결과는 하류 하천에서 서식하는 생물들에 영향을 미치지 않는 방류수의 수온 기준을 제시하는데 중요한 기초자료가 될 것으로 기대된다.

  • PDF

태양열 이용과 건물에너지 절약기술

  • 전홍석
    • 보일러설비
    • /
    • s.61
    • /
    • pp.56-63
    • /
    • 1999
  • 태양열 이용은 대체에너지자원 가운데 가장 널리 분포되어 있고 기술력에 따라 얼마든지 사용할 수 있는 태양열에너지를 그 대상으로 하고 있기 때문에 자연친화적이며, 친환경적인 접근방식으로 기술 개발 및 이용보급 정책을 함께 추진해야 할 것이다. 건물에너지 절약 기술도 국가에너지수요의 $30{\%}$이상을 차지하는 광범위하고 다양한 건물에너지 수요를 효율화하고 절감하는데 그 목적이 있으므로 기존의 건물에너지 이용방식의 문제, 효율개선방안, 그리고 신기술개발 및 환경친화적 건축설계등 기술 개발과 건축관련 정책을 병행 추진해야 그 효과를 기대할 수 있다. 따라서 기술개발 계획 수립, 연구개발 수행, 기술 이전 및 상용화 그리고 실용화 보급정책 시행의 전과정에 걸쳐 상호 보완적이고 체계적인 운용으로 효율을 극대화하고 파급효과를 높일 수 있을 것이다. 본 논문에서는 국가 에너지기술개발 10개년 계획의 목표와 틀 안에서 대체 에너지 기술 개발사업과 에너지 효율향상 기술개발 사업에 포함되어 있는 태양열 이용과 건물 에너지 절약기술에 관련된 프로그램들을 중심으로 효율적 운영방안 등을 검토하고자 한다. 또한 각각의 프로그램들이 가지는 특성과 연관성을 검토하여 추가 보완사항이나 정책대안을 제시하고자 한다.

  • PDF

기술개발-메탄가스 발생장치 개랑성공

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.9 no.5 s.84
    • /
    • pp.51-54
    • /
    • 1976
  • 과학과 기술이 발달하고 생활수준이 높아질수록 에너지의 소비량은 누증된다. 이 중에도 특히 열에너지는 대부분 석유나 석탄에 의존할 수 밖에 없는 것이 우리나라의 실정인 것이다. 우리나라의 에너지 총소비량 54.169억둔(1975년도 상공부 에너지개발과 발표)을 어떻게 얼마나 석유와 석탄으로 충당해 나갈 수 있느냐가 문제인 것이다. 석유파동으로 한번 큰 쇼크를 받었었다. 석탄의 매장량에도 한계가 있다. 여기서 이에 대체할 수 있는 방법이 없을까 해서 온 세계는 태양열발전을 서두루고 천연개스 발전 또는 지하석유자원발굴에 혈안이 되고 있다. 그런데 아직까지도 효율이 좋고 필요한 양을 자유로히 입수할 수 있는 석유등의 화석연료가 있기 때문에 새로운 연료자원의 개발이나 보급이 잘 안되는 원인의 하나였다 하겠다. 그러나 오늘날 점점 석유는 양적 한계와 제적이 심해질 뿐 아니라 언제또 공급에 제동이 걸릴지 모르고 격증하는 에너지를 보완하기 위해서는 새로운 에너지원의 개발을 서두루지 않으면 않되게 된 것이다. 자연자원중에서도 원료공급량이 풍부하고 비교적 간단한 시설로 얻어지는 메탄개스를 이용해보자는 계획이 지난 '69년도부터 산림녹화, 농촌연료해결, 환경개선등을 위해 정부시책의 일환으로 전국 농촌에 「메탄개스」이용을 관장해 왔다. 그러나 경제적부담이 힘겨운 농가사정과 시설상의 불합리, 관리의 불편등으로 호흥을 못받고 있는 실정이다. 여기서 이러한 여러가지 미비점을 과학적인 분석과 연구를 거듭하여 마침내 실용가능성을 보인 창원탱크 Co.(허범진씨)의 삼원식 메탄개스 발삼정화조라 하겠다.

  • PDF

Three-Dimensional Natural Convection from a Single Module on the Wall of a Vertical Parallel-Plate Channel (수직평행채널의 벽면에 부착된 단일모듈로부터의 3차원 자연대류 열전달)

  • Riu, K.J.;Lee, J.H.;Kim, H.W.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.29-41
    • /
    • 1999
  • Three-dimensional natural convective heat transfer in a vertical channel with a protruding single module was investigated experimentally. The particular interest was in the removal of thermal energy from the module by convective heat transfer. Hence radiative and conductive heat losses were estimated by using thermocouples and heat flux sensor respectively. The flow fields in the channel were visualized by means of a smoke-method. Also, local temperatures were measured by thermocouples inside the channel, along the vertical wall and module surface. It is found that convective heat transfer was promoted at the lower comer of the module and was decreased at the upper comer due to a recirculation zone. A general correlation of the critical channel ratios was found as a function of Rayleigh number. For the range of $8.28{\times}10^3<Ra^*_c<3.48{\times}10^6$, a useful correlation for the mean Nusselt number was proposed as a function of modified channel Rayleigh number.

  • PDF

Greenhouse Heating Characteristics of Heat Pump-Latent Heat Storage System (열펌프-잠열축열 시스템의 온실 난방 특성 연구)

  • 강연구;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.379-384
    • /
    • 2000
  • In order to use the natural thermal energy as much as possible for greenhouse heating, the air-air heat pump system involved PCM(phase change material) latent heat storage system was composed, and three types of greenhouse heating system(greenhouse system, greenhouse-PCM latent heat storage system, greenhouse-PCM latent heat storage-heat pump system) were recomposed from the greenhouse heating units to analyze the heating characteristics. The results could be concluded as follows; 1) In the greenhouse heated by the heat pump under the solar radiation of 406.39W/$m^2$, the maximum PCM temperature in the latent heat storage system was 24$^{\circ}C$ and the accumulated thermal energy stored in PCM mass of 816kg during the daytime was 100,320kJ. In the greenhouse without heat pump under the maximum solar radiation of 452.83W/$m^2$, the maximum PCM temperature in the latent heat storage system was 22$^{\circ}C$ and the accumulated thermal energy stored during the daytime was 52.250kJ. 2) In the greenhouse-PCM system without heat pump the heat stored in soil layers from the surface to 30cm of the soil depth was 450㎉/$m^2$. 3) In all of the greenhouse heating systems, the difference between the air temperature in greenhouse and the ambient temperature was about 20~23$^{\circ}C$ in the daytime. In the greenhouse without heat pump and PCM latent heat storage system the difference between the ambient temperature and the air temperature in the greenhouse was about 6~7$^{\circ}C$ in the nighttime, in the greenhouse with only PCM latent heat storage system the temperature difference about 7~13$^{\circ}C$ in the nighttime and in the greenhouse with the heat pump and PCM latent heat storage system about 9~14$^{\circ}C$ in the nighttime.

  • PDF

Estimation of Fire Emissions Using Fire Radiative Power (FRP) Retrieved from Himawari-8 Satellite (히마와리 위성의 산불방사열에너지 자료를 이용한 산불배출가스 추정: 2017년 삼척 및 강릉 산불을 사례로)

  • Kim, Deasun;Won, Myoungsoo;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_1
    • /
    • pp.1029-1040
    • /
    • 2017
  • Wildfires release a large amount of greenhouse gases (GHGs) into the atmosphere. Fire radiative power (FRP) data obtained from geostationary satellites can play an important role for tracing the GHGs. This paper describes an estimation of the Himawari-8 FRP and fire emissions for Samcheock and Gangnueng wildfire in 6 May 2017. The FRP estimated using Himawari-8 well represented the temporal variability of the fire intensity, which cannot be captured by MODIS (Moderate Resolution Imaging Spectroradiometer) because of its limited temporal resolution. Fire emissions calculated from the Himwari-8 FRP showed a very similar time-series pattern compared with the AirKorea observations, but 1 to 3 hour's time-lag existed because of the distance between the station and the wildfire location. The estimated emissions were also compared with those of a previous study which analyzed fire damages using high-resolution images. They almost coincided with 12% difference for Samcheock and 2% difference for Gangneung, demonstrating a reliability of the estimation of fire emissions using our Himawari-8 FRP without high-resolution images. This study can be a reference for estimating fire emissions using the current and forthcoming geostationary satellites in East Asia and can contribute to improving accuracy of meteorological products such as AOD (aerosol optical depth).

1kW RPG design and its stack performance model development (1kW급 가정용 연료전지 시스템 설계 및 스택 성능 예측 모델 개발)

  • Kim, Min-Jin;Sohn, Young-Jun;Lee, Won-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.287-287
    • /
    • 2009
  • 연료전지는 전기에너지와 열에너지를 동시에 사용 할 수 있기 때문에 에너지 효율이 높고 유해 배기물이 거의 없으므로 친환경적이다. 따라서 환경문제가 대두되고 있는 오늘날, 고효율 친환경의 연료 전지는 차세대 에너지원으로 각광받고 있다. 보일러와 계통선에서 열과 전기를 공급받는 기존방식에 비해 연료전지 코제너레이션 시스템의 경우 20%이상 에너지 절감율을 향상시킬 수 있다. 기존 10kW이하의 소용량 발전설비의 경우 대형 발전소와 같은 수준인 30%이상의 전기 효율을 기대할 수 없으나 고분자 전해질 연료전지를 적용할 경우 1kW급에서도 35%의 전기 효율을 기대할 수 있으며 열회수까지 고려할 경우 80%에 가까운 열효율을 달성할 수 있다.(4)연료전지 시스템은 연료전지 스택 이외에, 연료변환장치, 급기설비, 열 및 물관리 설비, 전력변환장치 그리고 제어 장치 등으로 구성된다. 연료전지 시스템 성능은 연료전지 스택의 성능에 가장 의존적인데 연료전지 스택의 성능은 같은 스택이라도 운전 및 제어 방법에 따라서 다양하게 변할 수 있다. 실제로 연료전지 스택 자체의 전기 변환 효율은 최대 40% 까지로 매우 높으나, 다양한 운전 조건에 따라 효율이 30~40% 수준에서 변화는 것이 현실이다. 때문에 시스템을 설계할 때에는 종합화된 시스템 측면에서의 운전까지 고려한 설계와 성능 해석이 필요하다. 그간 연료전지를 활용한 가정용 열병합 발전분야에서는 시스템 설계를 위한 시뮬레이션 기반 성능 해석에 관한 연구가 활발히 진행되어왔다. 하지만 연료전지 스택의 경우 간이화된 성능 모델식을 사용하여 이로 인한 성능 예측모델의 오차가 크게 발생하여 전체 시스템 최적화의 저해요인으로 작용하여왔다. 따라서 본 연구에서는 가정용 연료전지 열병합 발전 시스템을 자체적으로 설계 개발하였으며 이 중 연료전지 스택의 성능모델을 실험기반으로 구축하였다. 먼저 가정용 연료전지 열병합 발전 시스템의 설계는 크게 네 단계로 구분되며 이는 1) 시스템 개념 설계, 2) 연료전지 스택 설계, 3) 주변장치 설계, 4) 제어시스템 설계로 이뤄진다. 연료전지 스택의 성능 모델은 고분자연료전지의 성능에 가장 민감하게 영향을 미치는 온도 및 습도의 변화에 따른 다양한 스택 성능을 예측 가능하도록 개발하였으며 이는 간단한 이론 모델의 구조에 실험 데이터를 기반으로 모델 파라미터를 도출하는 기법으로 이뤄졌다.

  • PDF