Identification of pathogen and actual culture state of king oyster mushroom (Pleurotus eryngii) (큰느타리버섯 주요재배시 실태조사 및 병원균 분리동정)

  • Ha, Tai-Moon;Chi, Jeong-Hyun;Ju, Young-Cheuol;Sung, Jae-Mo
    • Journal of Mushroom
    • /
    • v.4 no.4
    • /
    • pp.135-143
    • /
    • 2006
  • We have investigated cultural circumstance and given condition of king oyster mushroom(Pleurotus eryngii) growing farmer. We collected many pathogens from King oyster mushroom growing farmer and identified with chemicobiological test and microscope. Most of investigated farmers neglected their's growing room cleaning and washing, after harvesting At pin-heading induction time, humidity degree in growing room was kept of high level and Air ventilation volume was so little that fruit-body formation ratio was low. The collected pathogens were twenty eight strains and identified with Pseudomonas sp., Trichoderma sp. mostly. During the spawn running time and pin-heading induction time, contamination by Trichoderma sp. occurred mostly, but during the fruit-body growing time, contamination by Pseudomonas sp., Erwinia sp. etc, occurred.

  • PDF

A study on the ventilation characteristics and design of transverse ventilation system for road tunnel (도로터널 횡류환기방식의 환기특성 및 시스템 설계 관한 연구)

  • Ryu, Ji-Oh;Kim, Hyo-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.305-315
    • /
    • 2018
  • In this study, the ventilation characteristics and the relationships between the required ventilation flow rate and the ventilation system flow rate was investigated by numerical method for the optimum design of the transverse ventilation and semi-transverse ventilation system in road tunnels. The following results were obtained. In supply exhaust transverse ventilation system, the system supply-exhaust air flow rate is theoretically equal to the difference between the required ventilation flow rate and natural ventilation flow rate. However, it is shown that it increases by about 10% in the analysis results. And, in the case of the longitudinal air flow rate is increased by installed jet fans, ventilation system air flow rate is reduced. However, as the longitudinal air flow rate increases, the concentration of pollutants in the tunnel decreases, so the exhaust effect of pollutants decreases, and the effect of reducing the system air flow rate is decreased. In case of semi-transverse with only air supply, ventilation system air flow rate is equal to required ventilation air flow rate when tunnel inlet velocity is negative, but results is shown it is increased within about 13.3%. Also, it was found that ventilation effect can not be expected even if the jet fans are increased when the tunnel inlet velocity is negative.

JET MOMENTUM CRITERIA FOR INLET CONTROL TO REDUCE WIND EFFECTS ON THE AIR DISTRIBUTION IN A SIDE-WALL-INLET VENTILATION SYSTEM (SIDE-WALL-INLET 환기시스템 축사에서 유입구의 컨트롤을 위한 젯트모멘텀)

  • ;Guoqiang Zhang
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.11a
    • /
    • pp.51-55
    • /
    • 1997
  • 국내의 축사는 윈치커튼의 위치를 조절하여 줌으로써 내부의 기류를 교환하는 개방형 축사가 대부분을 차지하고 있다. 개방형 축사의 환기는 외기풍속의 영향에의해 내부 기류의 흐름이 형성되어 바람이 없는 고온기에는 내부의 기류혼합이 잘 되지 않기 때문에 고온으로 인한 내부의 환경이 열악하다. 따라서 자연환기 축사에 배기팬 또는 입기팬을 설치하는 조합형 환기 축사가 주를 이를 것으로 판단된다. (중략)

  • PDF

VOC 흡착 분말활성탄의 폭발특성

  • 김성규;이경덕;김영수;신창섭
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.263-268
    • /
    • 2001
  • 휘발성유기화합물(Volatile Organic Compounds, VOC)은 연소배기가스중의 NOx, SOx와 함께 대기환경오염의 주 요인이 되는 물질로서, 제거방법의 하나로 활성탄 흡착법을 주로 사용한다. 흡착제로서 석탄이나 나무에서 제조된 활성탄(Activated Carbon)을 사용하는데, 활성탄 자체는 폭발하지 않으나 어느 정도 유기증기를 흡착하면 분산상태에서 폭발을 일으키는 것으로 알려져 있다 그러나, 국내에서 활성탄에 대한 연구는 자연발화위험성에 대해서만 연구가 진행되었을 뿐, 휘발성유기화합물이 흡착된 활성탄에 대한 연구는 전무한 상태이다.(중략)

  • PDF

Status and Major Lessons of Inland Waterways in Germany (독일 내륙수로에 대한 현황과 교훈)

  • Kim, Jong-Woo;Han, Kun-Yeun;Yoon, Sei-Eui;Kim, Gwang-Seob
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2071-2075
    • /
    • 2008
  • 독일 내륙수로의 길이는 12개강을 중심으로 7,306 km이며, 북해의 하구로부터 라인강 상류 바젤까지 여객과 화물이 운반된다. 또한 라인강과 마인강, 도나우강을 거쳐 동유럽을 관통하여 흑해까지 연결되어 물류의 이동뿐만 아니라 인적 및 문화의 교류가 활발히 이루어지고 있다. 독일 내륙 운하법은 연방내륙수로법, 선박기록규정법, 특허규정, 배기가스 규제에 관련된 법규 등으로 구성되었다. 특히 물길 잇기를 자연친화적인 방법으로 추진하였으며, 하천환경복원에 많은 투자와 배려를 아끼지 않았다. 라인강 상류지역을 직선하천으로 만들므로 홍수통제를 이루었으며, 하류지역 홍수범람문제의 해결책으로 상류지역에 천변저류지를 건설하였다. 또한 옛 가지천을 활용해서 지하수 수위 저감을 막을 수 있었다. 도나우강은 수로의 수심을 유지하기 위해 자연친화적인 공법을 적용하여 생태하천으로 복원되었다.

  • PDF

Combustion Property of Biodiesel Fuel (바이오디젤 연료의 연소 특성)

  • Song, Young-Ho;Shin, Baeg-Woo;Ha, Dong-Myeong;Chung, Kook-Sam
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2009
  • As the environmental pollution by the drastic increase of vehicles becomes one of the social major concerns, the method of reducing the harmful exhaust emission is being the subject of interest. Utilization of waste edible oil as a raw material for biodiesel production is helpful not only for the stable supply of raw materials but also costing down the biodiesel price. This study was conducted to examine the combustion and thermal characteristics with mixing ratio of biodiesel fuel. Flash points, fire points and autoignition temperature (AIT) were measured by using Tag closed cup, Cleveland open cup flash point tester and AIT apparatus. As the result, flash points, fire points and AIT increased with percentage of more contained biodiesel.

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

Smoke Control in a Subway Station Platform with Screen Doors - Based on Busan Subway Line 3 - (스크린도어 설치에 따른 지하승강장 제연의 문제점과 대책 - 부산 지하철 3호선을 중심으로 -)

  • Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.50-54
    • /
    • 2006
  • A fire in a subway station platform, completely isolated by screen doors, was numerically simulated to investigate problems in smoke control and find their countermeasures. A part of the platform, $40m{\times}5m$ floor and 3 m high, and a fire of 1 MW were considered, and the smoke extraction system was assumed to start operation at the onset of the fire. For three different values of the exhaust air flow rate, 0.1, 2, and $4m^3/min-m^2$, the distributions of temperature, concentrations of soot and carbon monoxide, and those of visibility were compared. The time-variations of the number of randomly distributed particles in the space were also investigated for the air flow rates to see the efficiency in smoke control. It was shown that smoke control takes time by lack of air supply. It was also confirmed that air supply from the railway to the platform at emergency is needed so that smoke is able to be controlled efficiently, and that opening the doors at the both ends of the platform is desirable until the fire is completely extinguished.

Separation of selenite and selenate using magnetite (마그네타이트를 이용한 selenite와 selenate의 분리)

  • Min, Je-Ho;Kim, Seung-Soo;Baik, Min-Hoon;Bae, Kie-Seo
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.298-303
    • /
    • 2011
  • Selenium is one of the interesting elements in human body, because it's important micro-nutrient for human health as the essential biological tissue in protein. Selenite ($SeO_3^{2-}$) and selenate ($SeO_4^{2-}$) are the dominant dissolved selenium species in natural water, and their toxicity and chemical properties are very different each other. Thus it is necessary to separate the two selenium species for understanding selenium behaviors in natural waters. Some reported methods, using an alumina-filled column and an ion chromatography, to separate the selenite and selenite may be difficult to directly apply to the natural water. Therefore magnetite selectively adsorbs selenite and selenate according to pH of solution, the separation of selenite and selenate using a magnetite-filled column was successfully obtained at weak alkali solutions. Moreover, the influence of dissolved anions in natural water at the selenite sorption onto magnetite was also investigated because they could hinder the sorption of selenite onto magnetite. In other to directly apply to the natural water, reactive sites of magnetite should be considered because dissolved silicate in natural water can hinder the adsorption of selenite onto magnetite.

A Study on the Ventilation Effects of the Shaft Development at a Local Limestone Mine (국내 석회석 광산 수갱 굴착에 의한 통기효과 분석 연구)

  • Lee, Changwoo;Nguyen, Van Duc;Kubuya, Kiro Rocky;Kim, Chang O
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.609-619
    • /
    • 2018
  • This study was carried out at a local limestone mine to analyze the ventilation efficiency of the shaft equipped with a main fan. The results show that its ventilation efficiency is clearly verified for the natural as well as the mechanical ventilation. The airflow rate of $11.7m^3/s$ was induced by the natural ventilation force and the maximum quantity is almost same as the airflow rate estimated by monitoring the average temperatures in the upcast and downcast air columns. Meanwhile, the airflow rate exhausted by the main fan through the shaft was $20.3{\sim}24.8m^3/s$; variation of the quantity was caused by the upward shift of the mine ventilation characteristic curve due to the frequent movement of the equipment. This indicates efforts are required to reduce the ventilation resistance and raise the quantity supplied by the main fan. The turbulent diffusion coefficients along the 1912 m long airway from the portal to the shaft bottom was estimated to be $15m^2/s$ and $18m^2/s$. Since these higher coefficients imply that contaminants will be dispersed at a faster velocity than the airflow, prompt exhaust method should be planned for the effective air quality control. The ventilation shaft and main fan are definitely what local limestone mines inevitably need for better working environment and sustainable development.