• Title/Summary/Keyword: 자속기준제어

Search Result 76, Processing Time 0.03 seconds

Sensorless Speed Control of Induction Motor using Model Reference Adaptive Control and Direct Torque Control System (모델기준적응제어 및 직접토크제어 시스템을 이용한 유도전동기의 센서리스 속도제어)

  • Kim, Sung-Hwan;Jeong, Bum-Dong;Yoon, Doo-O;Lee, Sung-Gun;Oh, Sae-Gin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2708-2715
    • /
    • 2012
  • This paper proposes a new sensorless speed control scheme of induction motor using Model Reference Adaptive Control and Direct Torque Control System. The Model Reference Adaptive Control System is based on the comparison between the outputs of Reference Model and Adjustable Model. The error between the estimated quantities obtained by the two models is used to drive a suitable adaptation mechanism which generates the estimated rotor speed for the Adjustable Model. And the Direct Torque Control scheme controls torque and flux by restricting the flux and torque errors within respective hysteresis bands, and motor torque and flux are controlled by the stator voltage space vector using optimum inverter switching table. The simulation results of proposed method indicate good speed responses from the low speed range to the high, and also show favorable characteristics of load operation.

Improved Maximum Efficiency Control of a Stator Flux-Oriented Induction Motor Drive (유도전동기 고정자자속기준제어의 개선된 최대효율제어)

  • Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.58-63
    • /
    • 2008
  • A fast maximum efficiency control scheme of a stator flux-oriented control of an induction motor is proposed. Three inputs of given three magnetic fluxes are calculated. Then magnetic flux for minimum input is calculated by quadratic interpolation method and maximum efficiency control is fulfilled with the calculated magnetic flux for minimum input. Simulation results verify the effectiveness of the scheme.

Estimation of Rotor Resistance and Stator Transient Inductance Using RLS in Stator Flux Oriented Control of Induction Motors (유도전동기 고정자 자속 기준 벡터제어에서 순환 최소자승법을 이용한 회전자 저항 및 고정자 과도 인덕턴스 추정)

  • Lee, Dae-Han;Choi, Jong-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.100-101
    • /
    • 2019
  • 본 논문은 유도전동기 고정자 자속 기준 벡터제어에서, 슬립 관계식과 순환 최소자승법을 이용하여 회전자 저항 및 고정자 과도 인덕턴스를 동시에 추정하는 알고리즘을 제안한다. 모의실험을 수행하여, 추정 회전자 저항과 고정자 과도 인덕턴스가 제안된 방법에 의해 각각 실제 값에 수렴함을 보인다.

  • PDF

Flux Compensation Method Using Torque Current Error in Field Weakening Region (약계자 영역에서의 토크분 전류제어 오차를 이용한 자속 보상)

  • Jeong, Se-Jong;Kim, Sung-Ki;Kim, Seung-Hwan;Han, Ki-Joon;Jung, Myung-Gil;Lee, Se-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.586-588
    • /
    • 2008
  • 농형 유도전동기의 센서리스 벡터제어시 기존의 약계자 알고리즘은 오토튜닝 오차에 의해 자속기준값이 크게 계산되어질 때 역기전력과, 전압제한값에 의해 최대전류를 출력할 수 없다. 본 논문에서는 약계자 영역에서 토크분 전류제어 오차를 이용하여 자속 기준값을 보상함으로써 전류부족에 의한 속도강하를 방지하는 알고리즘을 소개하였고, 시뮬레이션을 통해 그 타당성을 검증하였다.

  • PDF

Instantaneous Flux Weakening Control for High Speed Induction Machine (유도 전동기 고속 운정을 위한 순시적 약자속 제어)

  • Moon, Jooyoung;Lee, Hak-Jun;Yoo, Anno;Hong, Chanook;Lee, Jeongjoon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.207-208
    • /
    • 2015
  • 팬(fan), 펌프(pump), 블로어(blower), 전기 자동차(electric/hybrid vehicle), 전동차와 같은 다양한 분야에서 3상 전동기의 고속 운전에 대한 요구가 증대되고 있다. 일반적으로 3상 전동기가 정격 속도 이상의 고속에서 운전하기 위해서는 회전자 자속(rotor flux)의 크기를 운전 상황에 따라 감소시키는 약자속(flux weakening) 제어가 필수적이다. 유도 전동기의 회전자 자속 기준 벡터 제어 시의 약자속 운전은 자속 성분 전류의 크기를 제어하여 유도 전동기의 고속 운전을 가능하게 하는데, 이러한 전류 제어 기반의 약자속 제어는 그 구조가 복잡하고, 제어기 이득 선정에 따른 동특성(dynamic)이 영향울 받는 문제점을 가지고 있다. 본 논문에서는 이러한 단점을 개선하기 위한 순시적 약자속 제어 방법을 제안하고 3.7kW 유도 전동기를 이용한 실험을 통하여 제안된 방식의 성능을 검증한다.

  • PDF

Technique to Solve Problems Due to Load Increment in Maximum Efficiency Control of Stator Flux-Oriented Induction Motor Drive (유도전동기 고정자자속 기준제어의 최대효율제어에서 부하증가로 인한 문제 해결방법)

  • Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.69-74
    • /
    • 2007
  • Flux level is low in the maximum efficiency control of a stator flux-oriented control of induction motor under the light load. In this cast if the loaf torque is suddenly increased, torque component current is limited to the low level by torque-limit condition because of the low flux level. In this paper, a technique to solve the problem is proposed.

A DTC-PWM Control Scheme of PMSM based on an Approximate Voltage Function (근사 전압함수를 기반으로 하는 PMSM의 6-섹터방식의 DTC-PWM 제어 방식)

  • KWAK, YUNCHANG;LEE, DONG-HEE
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.39-40
    • /
    • 2013
  • 본 논문에서는 직접토크 제어에서 자속과 토크의 오차에 따라 결정된 전압벡터와 회전자 위치에 따른 실제 인가될 수 있는 d-q축 전압을 근사 전압함수로 근사화하여, 자속 및 토크오차와 전동기의 속도에 따라 듀티비를 결정하는 방식을 제안한다. 이러한 방식은 선택된 전압벡터가 일정한 상수 크기의 전압을 인가하는 것으로 가정된 기존의 직접토크 제어 방식에 비해 정밀한 전압 기준을 바탕으로 펄스폭의 듀티비를 결정함으로써, 동일한 스위칭 주파수 내에서 토크 및 자속오차의 크기를 감소 시킬 수 있는 장점이 있다.

  • PDF

Rotor Flux Estimation of an Induction Motor using the Extended Luenberger Observer (확장된 루엔버거 관측기를 이용한 유도전동기 회전자 자속 추정)

  • 조금배;최연옥;정삼용
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.115-124
    • /
    • 2001
  • In this paper, authors propose a new nonlinear rotor flux observer for rotor field oriented control of an induction motor which is designed based on the extended Luenberger Observer theory. Extended Luenberger Observer requires minimal solution of nonlinear partial differential equation on its coordinate transformation and linearization needed on a nonlinear observer design in general. The proposed rotor flux observer is derived from the 2 phase model of induction motor on the orthogonal coordination and it has the reduce gain matrix. Simulation and experimentation were performed under the conventional indirect vector control and direct vector control with the proposed observer at different rotor resistance. Simulation results show that the convergence of the proposed observer is influenced by the chosen eigenvalues. Experimentation results on load operation show the direct vector control with the proposed observer is better than the indirect vector control to maintain the characteristics of the vector control.

  • PDF

Performance Improvement of Induction Motor in Voltage Shortage State (전압 부족 상태 시 유도 전동기 성능 개선)

  • Kim, Hye-Seung;Kim, Jeong-Ha;Hong, Chan-Ook;Kim, Kyung-Seo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.466-471
    • /
    • 2009
  • The vector control algorithm has come to be used as induction motor for high performance torque and response improvement. This paper deals with new control algorithm which improves the performance of the rotor flux control by combining the conventional current controller with the flux controller and the hysteresis controller. In voltage shortage condition, proposed algorithm shows that the response and the stability can be improved both in the simulation results and in the experimental results.

고리 3/4호기 음의 중성자속 변화율 트립설정치 제거 연구

  • 이재용;이창섭;송동수;김종걸;이동혁
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.543-548
    • /
    • 1996
  • 이 연구의 목적은 고리 3/4호기 및 영광 1/2호기의 음의 중성자속 변화율에 의한 원자로 트립(NFRT) 설정치를 제거하여 불의의 제어봉 낙하 사고시에 원자로 트립을 방지하는 것이다. 현재의 인허가된 안전해석 방법론에 의하면 제어봉 낙하사고시에 NFRT에 의하여 원자로가 트립되고 결국 발전소의 이용율이 감소하게 되는데 본 연구에서 적용된 새로운 방법론으로는 이 NFRT 보호신호 없이도 제어봉 낙하사고시에 발전소의 안전성을 입증할 수 있다. 안전분석은 주기별로 다른 핵설계 자료 즉, 냉각재 온도상수, 전출력에서의 제어봉가 및 제어봉 삽입한계 등을 이용하여 수행되었다. 웨스팅하우스형 연료인 OFA 및 V5H에 대하여 고리 4호기 6주기외 3개 주기에 대하여 분석되었다. 분석된 주기들에 대해서 NFRT 신호 없이도 핵비등 이탈률(DNBR) 설계기준을 모두 만족하였다. 그러므로 고리 3/4호기 및 영광 1/2호기의 NFRT 신호는 제거할수 있고 이로써 제어봉 낙하사고시의 발전소 불시정지를 방지할수 있다.

  • PDF