• Title/Summary/Keyword: 자세 평가 프로그램

Search Result 71, Processing Time 0.027 seconds

인터넷(internet)을 이용한 인간공학적 작업장 평가 프로그램의 개발

  • 홍창우;김유창;김창제
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.05a
    • /
    • pp.307-312
    • /
    • 2002
  • 새로운 산업 구조와 변화된 사회 환경으로 인해 우리나라에서 최근 급증하고 있는 직업병 중의 하나가 직업 성 근골격계질환(Work-related Musculoskeletal Disorders, WMSDs)이다. 이 질환은 특정한 신체 부위의 반복 작업과 불편하고 부자연스러운 작업 자세, 강한 노동 강도, 과도한 힘, 불충분한 휴식, 추운 작업 환경, 진통 등이 원인이 되어 목, 어깨, 팔꿈치, 손목, 손가락, 허리, 다리 등 주로 관절 부위를 중심으로 근육과 혈관, 신경 등에 미세한 손상이 생겨 결국 통증과 감각 이상을 호소하는 근골격계질환의 만성적인 건강장해다.(중략)

  • PDF

DEVELOPMENT AND ANALYSIS OF IMAGE REGISTRATION PROGRAM FOR THE COMMUNICATION, OCEAN, METEOROLOGICAL SATELLITE(COMS) (통신해양기상위성의 영상위치유지 성능평가 프로그램 개발 및 분석)

  • Lee, Un-Seob;Choi, Yoon-Hyuk;Park, Sang-Young;Bang, Hyo-Choong;Ju, Gwang-Hyeok;Yang, Koon-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.3
    • /
    • pp.235-248
    • /
    • 2007
  • We developed a software for simulations and analyses of the Image Navigation and Registration (INR) system, and compares the characteristics of Image Motion Compensation (IMC) algorithms for the INR system. According to the orbit errors and attitude errors, the capabilities of the image distortions are analyzed. The distortions of images can be compensated by GOES IMC algorithm and Modified IMC (MIMC) algorithm. The capabilities of each IMC algorithm are confirmed based on compensated images. The MIMC yields better results than GOES IMC although both the algorithms well compensate distorted images. The results of this research can be used as valuable asset to design of INR system for the Communication, Ocean, Meteorological Satellite (COMS).

Analysis of the Convergence Pulmonary Function in the 20s Men of Mild Intellectual Disabilities with Obesity According to Position Changes (경도 지적장애를 가진 20대 남성 비만인의 자세변화에 따른 융합적인 폐기능에 대한 비교)

  • Park, Seung-Hwan;Kim, Ok-Ki;Seo, Kyo-Chul
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.67-74
    • /
    • 2019
  • The purpose of this study was to determine whether changes of position might effect the convergence pulmonary function of the 20s men of mild intellectual disabilities with obesity. Ten subjects of mild intellectual disabilities with obesity(fat group) and ten contrary subjects without obesity(control group) were participated in the experiment. Subjects were assessed for their pulmonary function by using Fit mate according to the position changes(supine position, 45 lean sitting position, 90 sitting position). One-way repeated ANOVA analyzed each region data of pulmonary function of both the fat group and the control group according to their position changes. The result of the experiment showed that the 20s men of mild intellectual disabilities with obesity have lower pulmonary function than the contrary subjects in the each given posture. In comparison with three experimental positions, supine position was the lowest in the pulmonary function. This study showed the 20s men of mild intellectual disabilities with obesity have lower function of pulmonary volume than the control group, and thus, it suggests that the pulmonary functional data of 20s men of mild intellectual disabilities with obesity in this experiment can be used as a basic respiratory one for the various exercise programs in the area of the physical activities.

Quality Assessment for Elbow CT scan by positioning and respiratory control (팔꿈치관절 CT검사에서 환자 자세 및 호흡에 따른 화질평가)

  • Lim, Jong-Chun;Park, Sang-Hyun;Lee, In-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.110-114
    • /
    • 2017
  • Because the arm can't be sutured due to fracture during a elbow CT scan, a CT scan is proceeded in a state of abdomen and L-spire are overlapped which beam hardening artifact is done many times, and it often lowers the quality of elbow CT images. So there are many difficulties in reading and due to increase in radiation dose from it, the number of patient's exposure keeps increasing. In this research, it plans to improve the quality of the images by avoiding overlap with abdomen, and increasing the number of photon overlapped with lung field which the line attenuation is relatively small. The way of experiment is based on patient's right elbow and place him as head first position, then place his elbow at L2-3 level in supine position, turn about 30 degrees to the left in non-control breathing and in supine position, and compared with full inspiration after overlapping with lung. After figuring out the average value and standard deviation data using Image J program 5 times each for 16, 128 channels, the evaluation is proceeded by measuring each of CNR, MSR are statistically analyzed using SPSS program. Therefore, through positioning and inspiration during elbow CT scan, the way of inspection minimized the exposure radiation dose, and seems to be meaningful in a way to improve the quality of the images.

Scientifically Gifted Students' Perception of the Impact of R&E Program based on KAIST Freshmen Survey (R&E 프로그램을 체험한 과학영재들의 사사교육 프로그램 효과에 대한 인식: KAIST 신입생을 중심으로)

  • Kim, Kyoung-Dae;Sim, Jae-Young
    • Journal of The Korean Association For Science Education
    • /
    • v.28 no.4
    • /
    • pp.282-290
    • /
    • 2008
  • The Research and Education (R&E) program was a year-long, apprenticeship and research-based program that was guided by mentors who are scientists or science teachers. The objective of the R&E program was to help scientifically gifted students in Korea Science Academy (KSA) and Science High Schools (SHS) to enhance abilities in creative thinking, scientific inquiry, problem solving, positive attitude towards scientists, and promoting cooperative research and interests in science and technology. In this study, the impact of the R&E program on the goals of 182 gifted college students in KAIST was evaluated using Likert-type items and multiple-choice method approach that provided a more comprehensive evaluation of the program's impact on science attitudes, creative thinking, scientific inquiry, and interests in science and technology. The results indicated a positive impact on cooperative research, gaining knowledge on the research topic, attitude towards scientists, interest in science and technology, scientific inquiry, and creative thinking in that order. There were rather remarkable and meaningful differences in science inquiry (p<.05), and scientific knowledge (p<.01), between the two groups of KAIST freshmen who came from SHS and KSA in 2006. Implications for science apprenticeship or a research-based mentorship program and their respective evaluations are also discussed.

Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images (방사선치료 시 환자자세 검증을 위한 분석용 도구 개발)

  • Lee Suk;Seong Jinsil;Kwon Soo I1;Chu Sung Sil;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.100-106
    • /
    • 2003
  • Purpose : To develop a patients' setup verification tool (PSVT) to verify the alignment of the machine and the target isocenters, and the reproduclbility of patients' setup for three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT). The utilization of this system is evaluated through phantom and patient case studies. Materials and methods : We developed and clinically tested a new method for patients' setup verification, using digitally reconstructed radiography (DRR), simulation, porial and digital images. The PSVT system was networked to a Pentium PC for the transmission of the acquired images to the PC for analysis. To verify the alignment of the machine and target isocenters, orthogonal pairs of simulation images were used as verification images. Errors in the isocenter alignment were measured by comparing the verification images with DRR of CT Images. Orthogonal films were taken of all the patients once a week. These verification films were compared with the DRR were used for the treatment setup. By performing this procedure every treatment, using humanoid phantom and patient cases, the errors of localization can be analyzed, with adjustments made from the translation. The reproducibility of the patients' setup was verified using portal and digital images. Results : The PSVT system was developed to verify the alignment of the machine and the target isocenters, and the reproducibility of the patients' setup for 3DCRT and IMRT. The results show that the localization errors are 0.8$\pm$0.2 mm (AP) and 1.0$\pm$0.3 mm (Lateral) in the cases relating to the brain and 1.1$\pm$0.5 mm (AP) and 1.0$\pm$0.6 mm (Lateral) in the cases relating to the pelvis. The reproducibility of the patients' setup was verified by visualization, using real-time image acquisition, leading to the practical utilization of our software Conclusions : A PSVT system was developed for the verification of the alignment between machine and the target isocenters, and the reproduclbility of the patients' setup in 3DCRT and IMRT. With adjustment of the completed GUI-based algorithm, and a good quality DRR image, our software may be used for clinical applications.

The Effects of Trunk Stabilization Training on a Stroke Patient's Postural Control and Activities of Daily Living: A Sing Subject Design (뇌졸중 환자의 체간안정화 훈련이 자세조절과 일상생활동작에 미치는 영향: 단일사례연구)

  • Nam, Ju-Hyeon;Shim, Gyeong-Bo;Gwak, Seong-Won
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.1
    • /
    • pp.75-84
    • /
    • 2014
  • Objective : This study intends to suggest an effective clinical intervention method for stroke patients by applying a trunk stabilization training program to a single stroke patient and investigating and analyzing the effects of the program on postural control and activities of daily living. Methods : The subject of this study was a 75 year-old female stroke patient hospitalized in C Hospital located in Gyeongju, Gyeongsangbuk-do. As for the research design, A-B-A reversal design was used with a single subject design; and the research period was a total of five weeks from April 21, 2014 to May 23, 2014. As for the research process, a total of 15 sessions were carried out including three sessions of baseline(A), nine sessions of an intervention period(B), and three sessions of maintenance(A'); and the trunk stabilization program was applied during the intervention period. To evaluate the participant's postural control and activities of living life, the Postural Assessment Scale for Stroke(PASS) and the modified Barthel Index(MBI) were used. Visual analysis was used in which collected data were plotted on a graph, using Microsoft Office Excel 2013. Results : In the postural control test, the mean scores improved from 11.7 in the baseline phase to 14.8 in the intervention phase and 15.3 in the maintenance phase. In the evaluation of activities of daily living, the score improved from 66(medium dependence) during the baseline period to 80(low dependence) after intervention and at the maintenance phase. Conclusion : It was found that the trunk stabilization training program showed effects on the stroke patient's postural control or alignment, and furthermore a beneficial improvement in the patient's performing the activities of daily living, as well.

  • PDF

Longitudinal Control Using Linear Quadratic Tracker with Integrator and Handling Qualities for Unmanned Rotorcraft (LQTI를 이용한 회전익 무인항공기 종방향 조종성 평가를 위한 제어법칙 설계 및 조종성 평가)

  • Lee, Changmin;Kim, Sungkeun;Jo, Seunghwan;Ra, Chunggil;Kim, Ki-joon;Suk, Jinyoung;Kim, Seungkeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.5
    • /
    • pp.393-400
    • /
    • 2017
  • A virtual simulation test program to carry out the handling qualities of unmanned Rotorcraft has developed by using the MATLAB GUIDE(Graphic User Interface Development Environment). The handling quality evaluation program based on ADS-33E contributes to design the flight control system and to evaluate handling qualities. In addition, Linear Quadratic Tracker with Integrator(LQTI) attitude controller based on Linear Quadratic Regulator(LQR) for to rotorcraft BO-105C and the effects of the handling qualities is analyzed change to weight matrices of the Q and R.

Bone Mineral Density Measurement of Rats Using Dual-energy X-ray Absorptiometry: Precision of In Vivo Measurements for Various Skeletal Sites with or without Repositioning (쥐에서 이중에너지 방사선 흡수법을 이용한 골밀도의 측정: 다양한 골부위에서 재위치 여부에 따른 생체내 측정의 정밀도)

  • Oh, Dong-Hyun;Jung, Jae-Ho;Woo, Sang-Keun;Cheon, Gi-Jeong;Kim, Byung-Il;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • Purpose: Bone mineral density (BMD) measurements need to be precise enough to be capable of detecting small changes in bone mass of rats. Using a regular dual-energy X-ray absorptiometry (DXA), we measured many BMD of various skeletal sites in rats to examine precision of DXA in relation to the repositioning on the bones of rats. Materials and Methods: Using DXA and small animal software, scans were performed 4 times in all 12 male rats without repositioning (Group 1a). Another four scans for 6 of 12 rats were done with repositioning between scans (Group 2). Customized regions of interest (ROIs), encapsulate the right hind limb, L1-4, skull and pelvic bones were drawn at each measurement. The precision of the measurements was evaluated by measuring the coefficient of variation (CV) of four measurements of BMD at each skeletal site of all rats with or without repositioning. Significance of differences between group 1b (six rats out of group 1a, which were come under group 2) and group2 were evaluated with Wilcoxon Signed Rank Sum Test. Results: CVs obtained at different skeletal sites of all measurements in Group 1b and 2. It was $3.51{\pm}1.20$, $ 2.62{\pm}1.20$ for the hindlimb (p=0.173), $3.83{\pm}2.02$, $4.59{\pm}2.02$ for L1-4 (p=0.600), $3.73{\pm}1.87$, $1.53{\pm}0.89$ for skull (p=0.046), and $2.92{\pm}0.60$, $1.45{\pm}0.60$ for pelvic bones (p=0.075). Conclusion: Our study demonstrates that the DXA technique has the precision necessary when used to assess BMD for various skeletal sites in rats regardless of repositioning.

Performance Assessment of Passive Micromixer using Numerical Analysis (수치해석을 이용한 패시브 마이크로 믹서의 성능평가)

  • Lee, Jeong-Ick;Kim, Chul-Kyu
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.10
    • /
    • pp.237-242
    • /
    • 2018
  • A micromixer is a component of a lab-on-a-chip or microfluidic device that mixes two or more chemicals together(convergence). The purpose of this study is to assess the performance of passive micromixer of various shapes. Six shapes of micromixers were compared and three dimensional modeling was carried out to have the same hydraulic diameter. The commercial code, ANSYS Fluent, was used to simulate the internal mixing flow. A numerical analysis method is described in detail in this paper. The performance of the micromixer was compared with the mixing index and pressure drop. Consequently, the CDM-8T shape showed reasonable mixing performance and relatively low pressure drop.