• Title/Summary/Keyword: 자세분석

Search Result 1,733, Processing Time 0.027 seconds

Effects of Electronic Security Service Quality Satisfaction and Customer Satisfaction on Switching Barrier and Customer Loyalty (기계경비 서비스품질만족과 고객만족이 전환장벽 및 고객충성도에 미치는 영향)

  • Kim, Chang-Ho;Yoon, Jong-Dae;Jung, Chul-Kyu;Lee, Bong-Keun
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.111-137
    • /
    • 2013
  • The purpose of this study is to examine the effects of electronic security service quality satisfaction and customer satisfaction on switching barrier and customer loyalty. Survey questionnaires were distributed to business owners in Seoul that are using electronic security system and the total of 500 copies were used as research data except 60 copies with insufficient responses. The results are as follow. First, as for the effects of electronic security service quality satisfaction on electronic security customer satisfaction, it indicates that the higher electronic security service quality satisfaction achieves, the more it has positive effects on electronic security customer satisfaction. Second, as for the effects of electronic security service quality satisfaction on switching cost, it indicates that the higher electronic security service quality satisfaction achieves, the more it has positive effects on switching cost. As for the effects of electronic security service quality satisfaction on human relations, it indicates that the higher electronic security service quality satisfaction achieves, the more it has positive effects on human relations. It indicates that the effects of electronic security service quality satisfaction on alternative attraction was not meaningful. Third, as for the effects of electronic security customer satisfaction on switching cost, it indicates that the higher electronic security customer satisfaction achieves, the more it has positive effects on switching cost. As for the effects of electronic security customer satisfaction on human relations, it indicates that the higher electronic security customer satisfaction achieves, the more it has positive effects on human relations. But, it indicates that the effects of electronic security customer satisfaction on alternative attraction was not meaningful. Fourth, As for the effects of electronic security service quality satisfaction and electronic security customer satisfaction on customer loyalty, it indicates that the higher electronic security service quality satisfaction achieves, the more it has positive effects on customer loyalty. As for the effects of switching cost on customer loyalty, it indicates that the higher switching cost achieves, the more it has positive effects on customer loyalty. As for the effects of alternative attraction on customer loyalty, it indicates that there is no meaningful relation between alternative attraction and customer loyalty. But, effects of human relations on customer loyalty, it indicates that there is no meaningful relation between human relations and customer loyalty. Based on the above results, it is noticeable that in the effects of electronic security service quality satisfaction and electronic security customer satisfaction on switching barrier, all of them had meaningful effects except for alternative attractiveness. This signifies that switching barrier factor can increase when the service quality of electronic security and customer satisfaction increase. In other words, it can be said that increased awareness of electronic security service quality satisfaction and electronic security customer satisfaction by electronic security users can lead to high customer loyalty by establishing switching barrier through such increased awareness.

  • PDF

A Case Study on Center of Gravity Analysis when Performing Uchimata by Posture and Voluntary Resistance Levels of Uke in Judo[ll] (유도 허벅다리걸기 기술발휘 시 받기의 자세와 저항수준에 따른 중심변인 분석 사례연구[II])

  • Kim, Eui-Hwan;Kim, Sung-Sup;Chung, Chae-Wook
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.237-257
    • /
    • 2005
  • It was to study as a following-research of "A Case Study on Center of Gravity(COG) Analysis when Performing Uchimata(inner thigh reaping throw) by Posture and Voluntary Resistance Levels(VRL) of Uke in Judo[I]". The purpose of this study was to analyze the COG variables when performing uchimata(inner thigh reaping throw) by two postures and voluntary resistance levels(VRL) of uke(reciver) in Judo. The subjects, who were one male judoka(YH) for 1992 Barcelona Olympic Games Olympian(silver medalist), and one male trainee; Y.I.University representative member (SDK), and were filmed on two S-VHS 16mm video cameras(60fields/sec.) through 3-dimensional motion analysis methods, that postures of uke were shizenhontai (straight natural posture) and jigohontai(straight defensive posture), VRL of uke were 0% and 100%, respectively. The kinematical variable was COG variable, distance of COG, and distance of resultant COG between uke and tori(the thrower), velocity and acceleration of COG. The data of this study collection were digitized by SIMI Motion Program computed the mean values and the standard deviation calculated for each variables. When performing uchinmata according to each posture and VRL of uke and classifying. From the data analysis and discussion, the conclusions were as follows : 1. Displacement of COG Subject YH, COG was the highest in kuzushi(balance -breaking), vertical COG was low when following in tsukuri(positioning; set-up), kake(application; execution), and COG was pattern of same character each postures and resistance, respectively. Subject SDK, COG was low from kumikata(engagement positioning) to kake, and COG was that each postures and resistance were same patterns, respectively. Subject YH, SDK, each individual, postures and resistance, vertical COG was the lowest in kake phase, when performing. 2. Distance of COG between uke and tori The distance of COG between uke and tori when performing, subject YH was $0.64{\sim}0.70cm$ in kumikata, $0.19{\sim}0.28cm$ in kake, and SDK was $0.68{\sim}0.72cm$ in kumikata, $0.30{\sim}0.42\;cm$ in kake. SDK was wider than YH. 3. Distance of resultant COG between uke and tori The distance of resultant COG between uke and tori when performing, subject YH was $0.27{\sim}0.73cm$ from kumikata to kake. and SDK was $0.14{\sim}0.34cm$ in kumikata, $0.28{\sim}0.65cm$ in kake. Jigohontai(YH:$0.43{\sim}0.73cm$,SDK:$0.59{\sim}0.65cm$) was more moved than shizenhontai(YH:$0.27{\sim}0.53cm$, SDK: $0.28{\sim}\;0.34cm$). 4. Velocity of COG The velocity of COG when performing uchimata, subject YH was fast anterior-posterior direction in kuzushi, ant.-post. and vertical direction fast in tsukuri and kake. SDK was lateral, ant.-post. and vertical direction in kuzushi, ant.-post. and vertical direction in tsukuri and ant.-post. direction in take, respectively. 5. Acceleration of COG The acceleration of COG when performing uchimata, The trend of subject YH was showed fast vertical direction in kuzushi and tsukuri, ant.-post. and vertical direction fast in kake. The trends of SDK showed lateral direction in kuzushi, lateral and ant.-post. direction in tsukuri and ant.-post. direction in kake, respectively.

Target Advertisement Service using a Viewer's Profile Reasoning (시청자 프로파일 추론 기법을 이용한 표적 광고 서비스)

  • Kim Munjo;Im Jeongyeon;Kang Sanggil;Kim Munchrul;Kang Kyungok
    • Journal of Broadcast Engineering
    • /
    • v.10 no.1 s.26
    • /
    • pp.43-56
    • /
    • 2005
  • In the existing broadcasting environment, it is not easy to serve the bi-directional service between a broadcasting server and a TV audience. In the uni-directional broadcasting environments, almost TV programs are scheduled depending on the viewers' popular watching time, and the advertisement contents in these TV programs are mainly arranged by the popularity and the ages of the audience. The audiences make an effort to sort and select their favorite programs. However, the advertisement programs which support the TV program the audience want are not served to the appropriate audiences efficiently. This randomly provided advertisement contents can occur to the audiences' indifference and avoidance. In this paper, we propose the target advertisement service for the appropriate distribution of the advertisement contents. The proposed target advertisement service estimates the audience's profile without any issuing the private information and provides the target-advertised contents by using his/her estimated profile. For the experimental results, we used the real audiences' TV usage history such as the ages, fonder and time of the programs from AC Neilson Korea. And we show the accuracy of the proposed target advertisement service algorithm. NDS (Normalized Distance Sum) and the Vector correlation method, and implementation of our target advertisement service system.

Evaluation of the accuracy of the HexaPOD evo RT system using Non-coplanar beams in lung cancer (폐암환자의 비동일평면 선속 빔 치료 시 HexaPOD evo RT system 의 정확성 평가)

  • Jang, Sewuk;cho, Kangchul;Lee, Sangkyoo;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2015
  • Purpose : The aim of this study, evaluate the accuracy of HeaxPOD evo RT system using the non-coplanar beam. Materials and Methods : 13 treatment plans are used which applied non-coplanar beams and 10 treatment plans which coplanar beams are used. the correction value what adjust to 6D couch is determined by each patient's setup errors only rotation direction. The study executed followings. first, Applying the correction value, measure the point dose and calculate the ${\gamma}$-index(${\gamma}=3%$ / 3 mm, ${\gamma}=2%$ / 2 mm). second, acquire data as previous methods without correction by HexaPOD. Results : For comparing the two results, we find out the more precise applying HexaPOD by point dose 0.2% in coplanar and non-coplanar. in the case of ${\gamma}$-index<1(${\gamma}=3%$ / 3 mm), more precise 2.2% in coplanar and 7% in Non-coplanar. Particularly, ${\gamma}$-index<1(2% / 2 mm) show the difference 9.2% in coplanar and 15.1% non-coplanar between apply HexaPOD and dose not apply HexaPOD. Conclusion : Using the HexaPOD is more precise than without HexaPOD. It suggests that HexaPOD evo RT system is very useful for precise and high dose delivery.

  • PDF

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

The Welfare Systems in Sweden and Korea with a Focus on the Demographic Transition (인구변천 과정에서 본 한국과 스웨덴의 복지 상태 비교)

  • 김성이
    • Korea journal of population studies
    • /
    • v.18 no.2
    • /
    • pp.51-69
    • /
    • 1995
  • The Swedish welfare state has been the model for others to emulate the archetypical example of state intervention. The state interventions are presented in the form of legal acts. These social welfare acts can be classified according to the demographic transition theory. According to the Bogue's theory, the demographic transition in Sweden took place in four stages : the pre-transitional stage before 1810; the early transitional stage from 1810 to 1860; the mid-transitional stage from 1860 to 1930; the late transitional stage from 1930 to now. As we look into the social welfare acts in Sweden, the relief of the poor was the major concern of the early transitional stage, the care of workers was the major concerns of the mid-transitional stage and the care of the families was the major concerns in the late transitional stage. The Korea's transition period can be devided as follows; the pre-transitional stage before 1960; the early transitional stage from 1960 to 1969; the mid-transitional stage from 1970 to 1987; and the late transitional stage from 1987 to now. In Korea, the major concern of the early transitional stage was the care of the officials and the workers; in the mid-transitional stage the care of the aged and the handicapped were the major concerns. And in the late transitional stage the expanding of the welfare clients was the major concern. If we compare the results of both countries, the relief of the poor, the care of the workers and the care of the families will be the major concerns in Korea, because the social welfare acts in Korea are extended to specific groups and not to the whole population. The acts related to these social issues have been arranged in 120 years in Sweden. But Korea had to do the same work in 27 years. So the burden of making those social acts will be four times heavier. If we want to extend the benefits of the social system to the general population, we need to look at the design and approach of the swedish model. The reason why swedish social acts constitute an international model has more to do with the uniqueness of its design and approach. First of all, it is characteristic by its universalism, secondly by its emphasis on social services and thirdly by its productivitism. Also the swedish welfare state supported by a high-tax system called the earnings-related welfare system. In order to achieve an effective welfare state, we Koreans should pay attention to the relief of the poor, the care of the worker and the families. We should also focus on a good system design and prepare appropriate budgets.

  • PDF

Correction of positional change of frontal cephalometric landmarks caused by vertical head rotation (두부의 수직회전 시 정모두부방사선사진상의 계측점 변화와 이의 보정)

  • Kim, Mi-Young;Lee, Kyung-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.98-111
    • /
    • 2011
  • Objective: Superimposition of frontal cephalograms cannot be performed when the cephalograms are taken with different vertical head rotations. The purpose of the present study was to evaluate the validity of correcting the positional change of frontal cephalometric landmarks caused by vertical head rotation. Methods: In 30 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle. Geometric principles of radiography were used to calculate the possible vertical and horizontal landmark changes if the head should be rotated down $5^{\circ}$ about an ear rod axis. The calculated changes were then compared with cephalometric changes measured on frontal cephalogram actually taken with the head rotated down $5^{\circ}$. Results: When the frontal cephalograms were taken with the head rotated down $5^{\circ}$ about an ear rod axis, significant changes in the vertical position of the landmarks occurred, particularly in the landmarks located farther anteriorly from the ear rod axis. The comparison of calculated changes and real cephalometric changes showed that the differences were less than 0.4 mm in the vertical direction and less than 0.2 mm in the horizontal direction. The differences between calculated and real changes were smaller in the landmarks less affected by vertical head rotation. Conclusions: Even when frontal cephalograms are taken at different vertical head rotations, the concomitant changes in the position of the landmarks can be corrected through calculation using the geometric principle of radiography as long as frontal and lateral cephalograms are taken perpendicular to each other.

The Role of Bronchoscopy for the Staging in Patient with Peripheral Lung Cancer (말초형 폐암 환자에 있어서 병기판정을 위한 기관지 내시경검사의 필요성)

  • Baek, Seung-Min;Sea, Hyang-Eun;Kim, Se-Hwan;Kim, Seong-Kyu;Kim, Yean-Jae;Lee, Byung-Ki;Kim, Won-Ho;Park, Jae-Yang;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.2
    • /
    • pp.147-154
    • /
    • 2001
  • Background : Bronchoscopy has been widely used for a histologic diagnosis through a transbronchial lung biopsy or for staging of patients with peripheral lung cancer. However a transthoracic needle aspiration (TTNA) has been used more widely for a histologic diagnosis in patient with a small size nodule or a nodule located in the outer portion of the lung because of the low diagnostic yield of bronchoscopy in these cases. The role of bronchoscopy for staging is not well established in patients with peripheral lung cancer diagnosed by a TTNA or patients who are undergoing surgery without a histologic diagnosis. Method: To evaluate the role of bronchoscopy for the staging in patients with peripheral lung cancer, who were diagnosed by TTNA, the medical records of 86 patients with peripheral lung cancer who underwent bronchoscopyat Kyungpook National University Hospital between January 1995 and May 1997 were reviewed. Results : While 53 cases had normal bronchoscopic findings, 33 cases had abnormal bronchoscopic findings comprising 9 cases of tumor, 10 cases of infiltration and 14 cases of compression of which there were 25 cases of T1 and 8 T2 endoscopically. The bronchoscopic staging did not influence the changes of the clinical stage of lung cancer. The frequencies of bronchial involvement tended to increase as the sizes of the nodule increased. Among the 42 patients who underwent surgery, 9 patients staged higher after operation because of lymph node involvement in 8 patients and the involvement of the pulmonary artery in 1 patient. No case staged above after operation due to a bronchial invasion. Conclusion : These findings suggests that bronchoscopy is not useful for staging in patients with peripheral lung cancer diagnosed by a TTNA.

  • PDF

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.